OEM Part Number Cross References:
Compatibility:
Manufacturer | Model |
---|
Draeger | Narkomed 4 |
---|
MEK | MP 1000, MP 700 |
---|
Welch Allyn | 53000, 5300P, 530T0, 530TP, 53N00, 53N0P, 53NT0, 53NTP, 53S00,
53S0P, 53ST0, 53STP, Propaq Encore |
---|
Cleaning the equipment:
To clean the sensor and its connecting cable, follow these steps:
Use warm soapy water: Clean the sensor and cable by gently washing
them with warm, soapy water. Ensure that the water is not too hot,
and use a mild soap or detergent.
Use a soft cloth with soapy water or 70% isopropyl alcohol: Moisten
a soft cloth with either soapy water or 70% isopropyl alcohol.
Gently wipe the probe and cable with the cloth, taking care not to
damage the surface of the visual indicator and the detector.
Avoid abrasive agents or chemical products: Do not use any abrasive
agents or chemical products except for 70% isopropyl alcohol. These
can potentially damage the sensor and its components.
Dry the probe and cable thoroughly: After cleaning, allow the probe
and cable to dry completely before using them again. Ensure that
there is no moisture remaining, as this can affect the proper
functioning of the equipment.
Avoid irradiation, autoclaving, soaking, or immersing the probe: Do
not subject the probe to irradiation, autoclaving, soaking, or
immersion in any type of solution. These actions can damage the
probe and compromise its performance.
Keep the probe clean and dry: It is important to maintain the
cleanliness and dryness of the probe during use. Regularly check
for any signs of contamination or damage and clean as necessary.
Average life expectancy: The average life expectancy of a SpO2
sensor is typically more than a year when used under the conditions
recommended in the operating instructions. Following the proper
cleaning and maintenance guidelines can help prolong the lifespan
of the sensor.
Equipment: * Connect the sensor cable to the appropriate device (pulse
oximeter) * Turn on the device and check correct operation by
consulting the monitor's operating instructions. *To ensure proper
operation of the monitor, please connect and disconnect the sensor
cable from the monitor cable. Use correctly and safely
The sensor and its connecting cable require system inspection at
least once or more per month, depending on frequency of use and
sanitization of the cable *Visual inspection (appearance of
insulator, connector contact pins, etc.) *Verification of
mechanical integrity of the connector Do not use and discard any
sensor with mechanical or electrical defects. The operating
conditions of the SpO2 sensor and its cable are as follows:
*Ambient temperature: 0° to +40° C
*Relative humidity: 0 to 80%
*Atmospheric pressure: 860 to 1060 HPa For use of SpO2 sensors and
their connecting cables in departments where compliance with
sterility levels is required, Med Accessories recommends the
following cleaning, disinfection or sterilization methods: