Compatible GE Healthcare > Marquette MD24-20 NIBP hose,
pedicatric dual tube hose
Compatibility:
Manufacturer | Model |
---|
Datex Ohmeda | Aespire 7900, B30, E-PRESTN, E-PRETN, E-PSM(P), E-RESTN, F-FM-00,
F-FML-00 |
---|
Draeger | Narkomed 6400 |
---|
GE Healthcare > Corometrics | 120, 128, 129, 250, 259, 259cx |
---|
GE Healthcare > Critikon > Dinamap | Carescape B105, Carescape B125, Carescape B450, Carescape B650,
Carescape B850 |
---|
GE Healthcare > Marquette | Dash, Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Eagle,
Eagle 3000, PDM Module, Procare B40, SOLAR, Tram, Tram 400, Tram
450, Tram 451, Tram 800, Tram 850, Tram 851 |
---|
Med Accessories is a company that specializes in providing oximetry
sensors for the continuous noninvasive monitoring of arterial
oxygen saturation and pulse rate. They offer a range of sensors
that are compatible with major brands of pulse oximeters, serving
as fully compatible replacement sensors.
The reusable sensors offered by Med Accessories are designed to
cater to four categories of patients:
Adult: These sensors are suitable for patients weighing greater
than 30 kg.
Pediatric: Designed for patients weighing between 10-50 kg.
Infant: Intended for patients weighing between 3-20 kg.
Neonatal/Adult: These sensors are suitable for patients weighing
less than 3 kg or greater than 40 kg.
To ensure compatibility and accurate monitoring, it is important to
select the appropriate sensor model number that matches the
specifications of your specific pulse oximeter. Med Accessories
takes care to design their SpO2 sensors to meet the requirements of
original equipment manufacturers (OEMs), ensuring reliable
performance.
When selecting a Med Accessories sensor for your pulse oximeter, it
is essential to consider the following reminders:
Compatibility: Verify that the SpO2 sensor connector is compatible
with the socket of your patient monitor. Different monitors may
have different types of connectors, such as 5-pin or 6-pin
connectors. It is crucial to match the sensor connector with the
socket on your specific patient monitor.
Patient Terminal Type: Determine whether you require a snap or clip
type of patient terminal for the SpO2 sensor. Some sensors have
snap-style connectors that easily attach to the patient's finger or
earlobe, while others use clip-style connectors that provide a
secure grip on the patient's finger. Choose the appropriate
terminal type based on your preference and the patient's comfort.
Patient Population: Confirm that the SpO2 sensor is suitable for
the intended patient population. Sensors are designed for different
age groups, such as adults or neonates. Ensure that you select a
sensor specifically designed for the age group of the patient you
are monitoring.
By adhering to these considerations and selecting the correct Med
Accessories sensor model for your pulse oximeter, you can ensure
compatibility and accurate monitoring of arterial oxygen saturation