2000GPM 146PSI Diesel Engine Split Case Fire Pump UL FM Approved

Country/Region china
City & Province wuhan hubei
Categories Pumps
InquireNow

Product Details

  • 2000GPM 146PSI Split Case Centrifugal Pump Diesel Engine Ul Fm Approved Fire Pumps Fire Water Pump

    Product Details

You can leave me a message about the flow, head, and other information about the project, I will recommend the most suitable pump set for you. Looking forward to your message. NMFIRE proven pumping systems meet changing and demanding conditions. No matter the pump type, size or system configuration, these is a sentinel solution to meet your needs.

 
 

Diesel Engine Pump Set( Heat Exchanger)
NM Fire Split Case Pump
Model SCF200-150-330(UL/FM)This Diesel Engine Group includes the pump(air relief valve, inlet & outlet gauges) Diesel Engine, Commonbase, Flexible exhaust connector, Control System, Battery, Silencer, Coupling (non-listed), Cooling System.
Please contact me if you need a Fuel tank, Main relief valve, Waste corn, or other accessories.
Capacity2000GPM
Head146PSI
RPM2950rpm
Material: 
CasingDuctile Cast iron
ImpellerSS304
ShaftAISI 4340
Shaft sleeveSS304
SealGland packing
Wear ringBronze
BearingSKF
Engine: Techtop/NMFIRE(UL/FM)
Model:Techtop/NMFIRE(UL/FM)
Controller: Tornatech (UL/FM)
Model:Tornatech
Jockey Pump set: 
Pump:NM FIRE 
Control PanelTornatech

 

 
 
 

  • NMFIRE

NMFIRE Factory-Built Containerized Pump Rooms combine a complete fire pump system, suction and discharge piping, electrical and exhaust components, all housed in a specially designed container. Pump Rooms are designed, built, and tested in a controlled ISO9001:2015 factory environment and shipped to the job site ready for immediate installation. The system piping and electrical connections are ready for immediate hook-up which significantly reduces on-site labor and shortens construction project timelines.

Value Added Systems
• 3D design built in an NFAP20 engineering environment with the highest quality
Standards
• All main components are UL/FM Listed and Approved products
• Complete system is pressure tested before shipment to eliminate on-site leaks
• All interior piping and electrical connections are complete
• Factory assembly and testing eliminates the need for on-site assembly
• Enclosure floor is coated
• Superstructure design supports the system piping, exhaust piping, and electrical components from the roof, allowing for more open floor space
• Wall insulation reduces environmental noise
• Includes all auxiliary systems prescribed by NFPA20 including:
• Heating • Lighting • Sprinklers • Ventilation • Drainage

  • Application:
 

All petroleum, petrochemical, chemical, military and naval institutes, oil fields of Petro China, Sinopec, CNOOC, pipelines Bureaus, oil repositories, oil terminals, construction companies, oil refineries, offshore platforms, etc.
Fire-fighting Engineering Companies, airports, highway tunnels, hotels, hospitals, supermarkets, office buildings, national grain storages, thermal power plants, shipyards, paper mills, subway stations, railway stations, etc.
Steel plants, residential regions, industrial and mining enterprises, house building materials supermarkets, etc.

 

  • Five Advantages of CNP NM FIRE

  • ①The late-mover advantage of products, we R&D better fire products than other Suppliers;②Have the most complete and all series of fire pump models;③Have listed diesel engines with the self-owned brand--- NM FIRE;④Understand the technology of fire- fighting products and fire- fighting system better than other competitors and have better services;⑤Shorter delivery time.

 
 

 
 
 
 

  • FAQ

 

Q1. Do you have the UL-LISTED Fire Pump Sets?
Yes, We have the UL/FM and NFPA standard Fire Pump Sets.
Q2. I need your motor drive End-suction/Split-casing fire pump, what information should I send to you?
Sir/Madam, you can provide the Capacity, Heed, Voltage, and Frequency, we will make the quotation for you, If you need a Jockey Pump or other accessories, please tell us together.
Q3. If I need your Diesel Engine Drive End-suction/Split-casing fire pump, what information should I send to you?
You can send the Capacity Heed, Temperature, and Altitude (temperature and altitude will affect the performance of diesel engines). If you need a Jockey Pump or other accessories, please tell us the Voltage and Frequency or accessories together.
Q4. I need the UL/FM Vertical Turbine Fire Pump Set, please sent me the price.
For the motor Diver Vertical Turbine Fire Pump Set: you should give us the Capacity, Heed, Voltage Frequency, and the tank deep.For the Diesel Engine Drive Vertical Turbine Fire Pump Set: you should give us the Capacity, Heed, and the tank deep. If you need a Jockey Pump or other accessories, please tell us together.

  • Service:

1. Reply within 24 hours.
2. High-quality products and the most reasonable price
3. Data and chemical technology support.


 
 
 

Hot Products

5000gpm UL/FM Fire Pumps For Oil And Gas Industry Projects UL/FM/Non-Listed Horizontal Split Case ...
3500GPM 130PSI Diesel Engine Split Case Centrifugal Pump Centrifugal Fire Pump Ul Fm Approved Fire ...
2000GPM 146PSI Split Case Centrifugal Pump Diesel Engine Ul Fm Approved Fire Pumps Fire Water Pump ...
750USGPM 93PSI End Suction Centrifugal Pump Tornatech Controller Fire Pump Horizontal End Suction ...
NMFIRE SCF125-100-330x2 Split Case Centrifugal Pump Fire Fighting Water Pump 750G PM 196 PSI ...
5000GPM Diesel Engine Split Case Centrifugal Pump For Fire Fighting High Flow High-Performance Ul Fm ...