Home Companies Shenzhen SORO Electronics Co., Ltd.

Nominal Voltage Optional 1000va Rack Mount Ups Battery Replacement For Personal Computers

Shenzhen SORO Electronics Co., Ltd.
Active Member

Contact Us

Address: Building B22 , Tantou West Industrial Park , Songgang Town , Bao'an District ,Shenzhen ,518105 P.R.CHINA

Contact name:Ella

Inquir Now

Shenzhen SORO Electronics Co., Ltd.

Nominal Voltage Optional 1000va Rack Mount Ups Battery Replacement For Personal Computers

City & Province shenzhen guangdong
Categories Uninterrupted Power Supply (UPS)
InquireNow

Product Details

 

 

 

 

Key Features:
1.Protects against downtime, data loss and process interruption by providing continuous, clean power


2.Offers premium performance with a 0.9 power factor and >95% efficiency


3.Increases battery service life and system uptime with ABM battery charging technology


4.Enables prolonged runtime of essential equipment during power outages by allowing for orderly, remote shutdown of non-critical systems or processes thanks to a capability to control load segments.


5.Provides installation flexibility with a choice of rack or tower designs, both conserving valuable space


6.Can replace batteries online, convenient for user to use


7.Enhanced monitoring and configuration capability through easily navigated multilingual graphical display.

 

 

 

Application:


IT and network environment, servers and network devices, telecom, VoIP and security systems, medical systems, diagnosis and medical screening system, Patient record archives, Manufacturing systems, Chip fabrication, Pharmaceutical production, Chemical processing

 

 


Technical Specifications of Online UPS HP9117C 1-3KVA:


Model
HP9117C 0.7-3KVA
1KT/1KR1KT-XL/1KR-XL2KT/2KR2KT-XL/2KR-XL3KT/3KR3KT-XL/3KR-XL
Capacity1KVA/900 W2KVA/1800 W3KVA/2700 W
Nominal Voltage100/110/120/127VAC or 200/208/220/230/240VAC
Nominal Frequency50/60 Hz
Input
Voltage Range60-138VAC or 115-276VAC
Frequency Range50HZ:(46~54HZ);60HZ:(56HZ~64HZ)
Power Factor>0.98
Output
Voltage precision100/110/120/127VAC(±2%) or 200/208/220/230/240VAC (±2%)
Frequency precision50Hz/60Hz±0.05Hz
Power Factor0.9
Harmonic DistortionLinear Load<3% Non-Linear Load<5%
Overload capacityoverload(110%~150%)after 30 seconds automatically transfer to bypass, it recover after normal load
Current Crest Ratio3∶1
Transfer time0ms(AC→DC)
Battery
DC voltage36VDC96VDC96VDC
Recharge time7 hours to 90%
Charge Current1A4A/8A(option)1A4A/8A(option)1A4A/8A(option)
Panel Display
LCDUPS status, input/output voltage frequency, battery voltage, capacity, load, temperature, history records
LanguageEnglish, French, German, Russian, Spanish
Communicate
Communicate interfaceOptional: SNMP card, AS400 card or the CMC provide software, EPO (USB port)
Working Environment
Temperature0~40℃
Relative humidity0~95% non-condensing
Storage Temperature-25℃~55℃
Elevation<1500 meter
Noise Level( 1meter)<45dB<45dB<50dB
Physics Characteristic
Net weigh(Kg)15168.593310.516.511.53411.51712.5
Gross weight (Kg)17.517.51111.53512.518.513.53613.51914.5
Dimension (WXDXH)
Main unit(Tower)200X400X145340X460X192340X460X192
Main unit (Rack mount)438X415X80455 X440 X90

 

 

 
APPLICATION OF OUR PRODUCT

 

1. Living house and home building

2. Office building, factory and warehouse

3. Shopping mall, stadium and so on

4. Power station, field operation and some huge engineer construction

5. suitable for various home appliance, Office equipment,Journeys, Camping, Tents, Boat Trip

 

 

 

COMPANY SHOW

 

Introduction of Company

Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.

Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.

 

 

 

WHY CHOOSE US ?

 

1, QC Control

The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.

2, Best Partner

We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.

 

 

FAQ

 

1. How to choose suitable inverter?

 

If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.

 

For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.

 

Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power

.......................................................................................................................................................................

 

2. How do I choose the size of the inverter?

 

Different types of load demand for power are different. You can view the load power values to determine the

size of the power inverter.

 

Notice:

 

Resistive load: you can choose the same power as the load.

 

Capacitive loads: according to the load, you can choose 2-5 times power.

 

Inductive loads: according to the load, you can choose 4-7 times power.

.......................................................................................................................................................................

3. How connection between batteries and an power inverter?

 

We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions

.......................................................................................................................................................................

 

4. How to calculate the load of working hours requires configuration of the battery size?

 

We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:

Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)

.......................................................................................................................................................................

Hot Products

THDI rack designs 3KVA / 2700 W , Non - Linear Load 110V UPS HP9117C I / O voltage Application: IT ...
N+X type Non - condensing 10kv Automatic alarm Rack Mountable UPS HP9316C DC staring Key Features ...
Pure Online 1 Kva 10 Kva 2kva Rack Mount Ups Uninterrupted Power Supply 8000w Key Features: 1.Large ...
High Reliability Online Rack Mount Ups Power Supply High Frequency 0.7 - 3kva High Frequency 1, 2, 3 ...
Key Features: 1.Protects against downtime, data loss and process interruption by providing ...
Computers 3kva Rack Mount Ups Backup Power Supply 0.9 Output Power Factor Key Features: 1.Protects ...