Product Details

PCS systems

Model : EPCS50,EPCS100 EPCS 150,EPCS200,EPCS250 Max. Capacity of system : 50kW,100kW 150kW,200kW, 250kW Power module model : PCM50 PCM50 Power module capacity : 50kW 50kW Dimension : 600*1000*2000(W*D*H)mm 1200*1000*2000(W*D*H)mm

High efficiency integrated PCS systems based on 50kW module

Model : EPCS50,EPCS100 EPCS 150,EPCS200,EPCS250

Max. Capacity of system : 50kW,100kW 150kW,200kW, 250kW

Power module model : PCM50 PCM50

Power module capacity : 50kW 50kW

Dimension : 600*1000*2000(W*D*H)mm 1200*1000*2000(W*D*H)mm

 

 

  Model EPCS50 EPCS100 EPCS150 EPCS200 EPCS250
Battery interface parameters Voltage range DC 680V-900V (without TX) / 580V-900V (with TX)
Max DC channel Qty 1 2 3 4 5
Single channel maximum current     85A    
AC grid-connected parameters Output 3W+N+PE/3W+PE 3W+N+PE/3W+PE
Rated power 50kW l00kW 150kW 200kW 250kW
Rated voltage     AC 380V/400V    
Rated Current 75A 151A 227A 303A 379A
Voltage range     ‘-15% ~ +10%    
Rated frequency     50Hz/60Hz    
Frequency range     ±2Hz    
Power factor     -0.9 〜+0.9    
Output harmonics     ≤3%    
Charge- discharge transition time     < 100ms    
AC off-grid parameters Output   3W+N+PE/3W+PE    
Rated power 50kW l00kW 150kW 200kW 250kW
Rated voltage     AC 380V/400V    
Rated frequency     50Hz/60Hz    
Rated Current 75A 151A 227A 303A 379A
Voltage accuracy     0.01    
Frequency accuracy     ±0.2Hz    
Output voltage harmonics     3%@ linearfull load    
Unbalanced load capacity     100%    
Overload capacity 105%]: continuous operation; (105% -120%]: lOmin; (120% -125%] : Imin; 125%); stop operation
Environment Working temperature -20°C〜55°C (>45°C derating)
Storage temperatu re -40°C〜70°C (No batteries)
Relative humidity 0% RH 〜95% RH, No condensation
Working altitude <45°C, 2000m ; 2000m 4000m Derating
Noise < 75dB
Others Communication CAN/RS485
Isolation Isolation Tranformer Optional
Protection IP20
Cooling Air cooling, intelligent fan regulation
Maximum efficiency 98.5% (no transformer)
Dimension W*D*H 600*1000*2000 1200*1000*2000
Weight 300kg 330kg 500kg 530kg 560kg
Certification EN50549/G99/IEC62477-1/EN61000/IEC61727/IEC62116

 

High efficiency integrated PCS systems based on 100kW module

 

Model:EPCS300,EPCS400,EPCS500,EPCS600

Max. Capacity of system:300kW,400kW,500kW,600kW

Power module model:PCM100

Power module capacity:100kW

Dimension:1400*1000*2000(W*D*H)mm

 

 

  Model EPCS300 EPCS400 EPCS500 EPCS600
Battery interface parameters Voltage range DC 680V-900V (without TX) / 580V-900V (with TX)
Max DC channel Qty 3 4 5 6
Single channel maximum current     170A  
AC grid-connected parameters Output 3W+N+PE/3W+PE
Rated power 300kW 400kW 500kW 600kW
Rated voltage     AC 380V/400V  
Rated Current 454A 606A 758A 909A
Voltage range ‘-15% ~ +10%
Rated frequency 50Hz/60Hz
Frequency range ±2Hz
Power factor -0.9 〜+0.9
Output harmonics ≤3%
Charge- discharge transition time < 100ms
AC off-grid parameters Output 3W+N+PE/3W+PE
Rated power 300kW 400kW 500kW 600kW
Rated voltage AC 380V/400V
Rated frequency 50Hz/60Hz
Rated Current 454A 606A 758A 909A
Voltage accuracy 1%
Frequency accuracy ±0.2Hz
Output voltage harmonics 3%@ linearfull load
Unbalanced load capacity 100%
Overload capacity 105%]: continuous operation; (105% -120%]: lOmin; (120% -125%] : Imin; 125%); stop operation
Environment Working temperature -20°C〜55°C (>45°C derating)
Storage temperatu re -40°C〜70°C (No batteries)
Relative humidity 0% RH 〜95% RH, No condensation
  <45°C, 2000m ; 2000m 4000m Derating
Noise < 75dB
Others Communication CAN/RS485
Isolation Isolation Tranformer Optional
Protection IP20
Cooling Air cooling, intelligent fan regulation
Maximum efficiency 98.5% (no transformer)
Dimension W*D*H 1400*1000*2000 1400*1000*2000
Weight 600kg 650kg 700kg 750kg
Certification EN50549/G99/IEC62477-1/EN61000/IEC61727/IEC62116

 

Integrated PCS systems with wide voltage range

 

Model: EHPCS-50/50,EHPCS-100/50 EHPCS-150/50,EHPCS-200/50,EHPCS-250/50

Max. Capacity of system:50kW,100kW 150kW,200kW, 250kW

Power module model:PCMZ50 PCMZ50

Power module capacity:50kW 50kW

Dimension:600*1000*2000(W*D*H)mm 1200*1000*2000(W*D*H)mm

 

 

  Model EPCS50/50 EPCS100/50 EPCS150/50 EPCS200/50 EPCS250/50
Battery interface parameters Voltage range DC 200V~DC 800V
Full Load Voltage range DC 370V~DC 800V
Max DC channel Qty 1 2 3 4 5
Single channel maximum current 135A
AC grid-connected parameters Output 3W+N+PE/3W+PE
Rated power 50kW l00kW 150kW 200kW 250kW
Rated voltage AC 380V/400V
Rated Current 75A 151A 227A 303A 379A
Voltage range -15% ~ +10%
Rated frequency 50Hz/60Hz
Frequency range ±2Hz
Power factor -0.9 〜+0.9
Output harmonics ≤3%
Charge- discharge transition time < 100ms
AC off-grid parameters Output 3W+N+PE/3W+PE
Rated power 50kW l00kW 150kW 200kW 250kW
Rated voltage AC 380V/400V
Rated frequency 50Hz/60Hz
Rated Current 75A 151A 227A 303A 379A
Voltage accuracy 0.01
Frequency accuracy ±0.2Hz
Output voltage harmonics 3%@ linearfull load
Unbalanced load capacity 100%
Overload capacity 105%]: continuous operation; (105% -120%]: l0min; (120% -125%] : Imin; 125%); stop operation
Environment Working temperature -20°C〜55°C (>45°C derating)
Storage temperatu re -40°C〜70°C (No batteries)
Relative humidity 0% RH 〜95% RH, No condensation
Working altitude 2000m ; 2000m~4000m Derating
Noise < 75dB
Others Communication CAN/RS485
Isolation Isolation Tranformer Optional
Protection IP20
Cooling Air cooling, intelligent fan regulation
Maximum efficiency 98.5% (no transformer)
Dimension W*D*H 600*1000*2000 1200*1000*2000
Weight 320kg 370kg 570kg 620kg 670kg
Certification EN50549/G99/IEC62477-1/EN61000/IEC61727/IEC62116

 

Hybrid PCS system with solar access

 

Model:SPCS50 SPCS100 SPCS150

MPPT:50kW 100kW 150kW

PCS:50kW 100kW 150kW

Dimension:600*1000*2000(W*D*H)mm 1200*1000^2000(W*D* H)mm 1200*1000^2000(W*D* H)mm

 

 

  Model EPCS50 EPCS100 EPCS150
Battery interface parameters Voltage range DC 200V~DC 700V
Full Load Voltage range DC 370V~DC 700V
Max DC channel Qty 1 2 3
Single channel maximum current 135A
Battery parameter Voltage range DC650V 〜DC850V
Maxcharging/discharging current 85A 170A 255A
AC grid-connected parameters Output 3W+N+PE/3W+PE
Rated power 50kW 100kW 150kW
Rated voltage AC 380V/400V
Rated Current 75A 151A 227A
Voltage range ‘-15% ~ +10%
Rated frequency 50Hz/60Hz
Frequency range ±2Hz
Power factor -0.9 〜+0.9
Output harmonics ≤3% (Rated power)
AC off-grid parameters Output 3W+N+PE/3W+PE
Rated power 50kW 100kW 150kW
Rated voltage AC 380V/400V
Rated frequency 50Hz/60Hz
Rated Current 75A 151A 227A
Voltage accuracy 1%
Frequency accuracy ±0.2Hz
Output voltage harmonics 3%@ linearfull load
Unbalanced load capacity 100%
Overload capacity 105%]: continuous operation; (105% -120%]: 10min; 120%); stop
Environment Working temperature -20°C〜55°C (>45°C derating)
Storage temperatu re -40°C〜70°C (No batteries)
Relative humidity 0% RH 〜95% RH, No condensation
Working altitude 2000m; 2000m~4000m Derating
Noise < 75dB
Others Communication CAN/RS485
Isolation No
On-off grid switching Yes
Protection IP20
Cooling Air cooling, intelligent fan regulation
Maximum efficiency 97.50%
Dimension W*D*H 600*1000*2000 1200*1000*2000 1200*1000*2000
Weight 550kg 750kg 850kg

Hot Products

· Suitable for ground power plants and distributed projects · Advanced module technology delivers ...
Suitable for ground power plantsand distributed projects Advanced module technology delivers ...
Mechanical Characteristics Cell Type Mono P-Type,182*182(±1)mm,144(6*24)Half-Cut Cells Glass 3.2mm...
Mechanical Characteristics Cell Type Mono N-Type,182*182(±1)mm,156(6*26)Half-Cut Cells Glass 3.2mm...
· Suitable for ground power plants and distributed projects · Advanced module technology delivers ...
· Suitable for ground power plants and distributed projects · Advanced module technology delivers ...