Home Companies SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED

0.500Kg Professional Digital Multimeter 600V with Backlight

SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED
Active Member

Contact Us

[China] country

Address: 502, No. 31, Yangmei Road, Bantian Street, Shenzhen, Guangdong, China

Contact name:Emily Tan

Inquir Now

SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED

0.500Kg Professional Digital Multimeter 600V with Backlight

Country/Region china
City & Province shenzhen guangdong
Categories Electric Wrenches
InquireNow

Product Details

4 in 1 O2 H2S CO Gas Detector with Gas Sampler Pump for Gas Leak Detector 
 
Description


- instrument for the portable, professional measuring instruments, with LCD digital display, and a backlight,
Users are easy to read. The range switch is easy to measure with one hand operation, with overload protection and low battery indication. Whether professional, factory, school, enthusiast or family use, are an ideal
Multi-function instrument.
- instrument for AC current, DC current, AC voltage sine wave true RMS, DC voltage, frequency, duty cycle, resistance, capacitance measurement and line off, diode testing, temperature measurement.
- The instrument has an automatic range function.
- The meter has a reading hold function.
- The instrument has an automatic shutdown function.
 
 
Technical indicators
 
Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
3.2.1 True rms zero input
3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.
 
 
 
3.2.2 DC voltage

RangeResolutionAccuracy
6V0.001V±(0.5% of reading + 5 words)
60V0.01V
600V0.1V±(0.8% of reading + 5 words)

- Input impedance: 10MΩ
- Maximum input voltage: 600V DC or 600V AC (rms)
Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
 
 
3.2.3 AC voltage
 

RangeResolutionAccuracy
6V0.001V±(0.8% of reading + 3words)
60V0.01V
600V0.1V±(1.0% of reading + 10words)

- Input impedance: 10MΩ

- Maximum input voltage: 600V AC (RMS) or 600V DC

- Frequency range: 40 ~ 1000Hz True RMS

Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
 
 
 
3.2.4 Alternating current
 

RangeResolutionAccuracy
600.0uA0.1uA±(1.5% of reading +10words)
6000uA1uA
60.00mA0.01mA
600.0mA0.1mA
6A0.001A±(2.5% of reading +10words)
10A0.01A

- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
- Frequency response: 40Hz ~ 1000Hz True RMS.
 
3.2.5 DC
 

RangeResolutionAccuracy
600.0uA0.1uA±(1.0% of reading +5words)
6000uA1uA
60.00mA0.01mA
600.0mA0.1mA
6A0.001A±(2.0% of reading +10words)
10A0.01A

- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
 
 
3.2.6 Frequency
 

RangeResolutionAccuracy
9.999Hz0.001Hz±(1.0% of reading +3words)
99.99Hz0.01Hz
999.9Hz0.1Hz
9.999kHz0.001kHz
99.99KHZ0.01kHZ
999.9KHZ0.1KHZ
9.999MHZ0.001MHZ

- Overload protection: 250V DC or AC (rms)
- Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)
 
 
3.2.7 Duty cycle
 

RangeResolutionAccuracy
0.1 – 99.9%0.1%± 3.0%

- Frequency response: 10 ~ 10MHz

- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)

- Maximum input voltage: 250V AC (rms)
 
 

Resistance
 

RangeResolutionAccuracy
600W0.1W±(0.8% of reading +3words)
6kW0.001kW
60kW0.01kW
600kW0.1kW
6MW0.001MW±(1.2% of reading +3words)
60MW0.01MW

- Open circuit voltage: approx. 1.0V
- Overload protection: 250V DC or AC (rms)
 

Transistor test

 

RangeDescriptionTest Conditions
hFEThe display reads the approximate value of hFE(0~1000)Base current of about 10uA; Vce about 2.8V

 

 

Capacitance

 

RangeResolutionAccuracy
9.999nF0.001nF±(4.0% of reading +3words)
99.99nF0.01nF
999.9nF0.1nF
9.999mF0.001mF
99.99mF0.01mF
999.9mF0.1mF
9.999mF0.001mF±(5.0% of reading +3words)
99.99mF0.01mFNot calibrated

- Overload protection: 250V DC or AC (rms)

 

 

Temperature test

 

RangeAccuracyResolution
-20℃-300℃±(1.0%+4d)1℃
301℃-1000℃±(1.9%+5d)1℃
-4℉-600℉±(1.2%+6d)1℉
601℉-1832℉±(1.9%+6d)1℉

- Overload protection: 250V DC or AC (rms)

 

 

Hot Products

Automatic Shutdown Diode Test Infrared Themometer IEC1010-I CAT 100V Description: - instrument for ...
Digital Temperature Tester Moisture Meter For Food Or Building Material Description: 1. Overload ...
1A/10A 1uF/10uF/100uF/1mF Infrared Themometer Duty Cycle 0.1% - 99% Description: Before turning the ...
Automatic Range Infrared Themometer Capacitance Measurement Description: - instrument for AC current...
4 in 1 O2 H2S CO Gas Detector with Gas Sampler Pump for Gas Leak Detector Description - instrument ...
Mestek Portable combustible gas leak detector for CH4, CO,C2H6 Description - instrument for the ...