Shanghai Schneider-Sunshine Mechanical Group Co.,Ltd. |
|
1.2~1.7m³/min Two Stage Screw Air Compressor Energy 11KW Air
Cooling
◆ Product Description
We are the leading organization actively
occupied in providing an extensive series of Tandem Two Stage Screw
Air Compressor. This product is presented in numerous of
specifications.
As a benchmark of this industry, we are
involved in offering a huge range of Tandem Two Stage Screw Air
Compressor. Under the strict guidance of our technical experts, the
offered compressors are precisely manufactured with the aid of
ultra-modern techniques by utilizing the finest quality components.
The volumetric efficiency of two-stage is better than single-stage
compression. In addition, the Screw Compressors are available in
vivid technical specifications.
⊙ Type air compressor pause
Specifacation | Cooling Style | Air Capacity (m³/min) | Discharge Pressure (bar) | Motor Power (kw) | Speed (r/min) | Voltage(V) Frequency(Hz) | Cooling Air Capacity (m3/min) | Joint pipe Size (inch) | Total Weight (kg) | Dimension(L*W*H) (mm) |
SRC-7.5SA | Air cooling | 0.85 | 7 | 5.5 | 2980 | 380V50Hz | 80 | 1/2″ | 230 | 850*735*990 |
0.8 | 8 | |||||||||
0.6 | 10 | |||||||||
0.4 | 13 | |||||||||
SRC-10SA | Air cooling | 1.1 | 7 | 7.5 | 2980 | 380V50Hz | 80 | 1/2″ | 410 | 850*735*990 |
1 | 8 | |||||||||
0.8 | 10 | |||||||||
0.6 | 13 | |||||||||
SRC-15SA | Air cooling | 1.7 | 7 | 11 | 2980 | 380V50Hz | 80 | 1/2″ | 475 | 1100*750*1150 |
1.6 | 8 | |||||||||
1.4 | 10 | |||||||||
1.2 | 13 | |||||||||
SRC-20SA | Air cooling | 2.4 | 7 | 15 | 2980 | 380V50Hz | 100 | 1″ | 560 | 1350*850*1150 |
2.2 | 8 | |||||||||
2.1 | 10 | |||||||||
1.7 | 13 | |||||||||
SRC-25SA | Air cooling | 3.1 | 7 | 18.5 | 2980 | 380V50Hz | 145 | 1″ | 580 | 1350*850*1150 |
2.9 | 8 | |||||||||
2.7 | 10 | |||||||||
2.2 | 13 | |||||||||
SRC-30SA | Air cooling | 3.8 | 7 | 22 | 2980 | 380V50Hz | 145 | 1″ | 640 | 1350*850*1150 |
3.5 | 8 | |||||||||
3.2 | 10 | |||||||||
2.7 | 13 | |||||||||
SRC-40SA | Air cooling | 5.2 | 7 | 30 | 2980 | 380V50Hz | 255 | 1″ | 900 | 1350*850*1150 |
5 | 8 | |||||||||
4.3 | 10 | |||||||||
3.7 | 13 | |||||||||
SRC-50SA | Air cooling | 6.4 | 7 | 37 | 2980 | 380V50Hz | 255 | 1½″ | 980 | 1550*950*1450 |
5.9 | 8 | |||||||||
5.5 | 10 | |||||||||
4.8 | 13 | |||||||||
SRC-60SA | Air cooling | 8 | 7 | 45 | 2980 | 380V50Hz | 255 | 1½″ | 1050 | 1550*950*1450 |
7.7 | 8 | |||||||||
7 | 10 | |||||||||
5.8 | 13 | |||||||||
SRC-75SA | Air cooling | 10.5 | 7 | 55 | 2980 | 380V50Hz | 268 | 2″ | 1250 | 1900*1240*1700 |
9.8 | 8 | |||||||||
8.7 | 10 | |||||||||
7.5 | 13 | |||||||||
SRC-90SA | Air cooling | 11.7 | 7 | 65 | 2980 | 380V50Hz | 268 | 2″ | 1530 | 1900*1240*1700 |
11.3 | 8 | |||||||||
9.5 | 10 | |||||||||
8.4 | 13 |
◆ Selection of volume flow rate
① When choosing the volume flow rate of air compressor, we should
first know the volume flow rate of all the gas-using equipment and
multiply the total flow rate by 1.2 (that is, to enlarge the 20%
margin).
② the new project can be selected according to the flow rate
provided by the design institute.
③ to understand the volume and flow parameters of the gas
consumption equipment for the gas supplier.
④ Air compressor station transformation can refer to the original
parameter value and the actual gas consumption.
Appropriate type selection is beneficial to
users and air compressor equipment. Too much waste of type
selection and too small type selection may cause the air compressor
to be in a long-term loading state or insufficient gas consumption
or pressure can’t be beaten up.