Results forsafety electric infusion pumpfrom 39056 Products.
|
Lightning surge symmetry line and asymmetric coupling networkDATA-CDN Series mVoltage wave :1.2/50 s open circuit with 10/700μs( waveform generator output) Maximum voltage tested ...
|
|
|
|
Symmetric Line Coupled NetworkDATA-CDN-4A m Voltage wave :1.2/50 s open circuit with 10/700μs( waveform generator output) Maximum voltage tested :6 kV Matching resistance :25 R,40R...
|
|
|
|
Discharge Network Suite Optional according to different standards: Discharge capacitance :100 pF,150pF,200pF,250pF,300pF 400pF,500pF Discharge resistance :Ω,100Ω,150Ω,200Ω,300Ω,330...
|
|
|
|
Unsymmetrical coupled decoupling networkDATA-CDN-4B mVoltage wave :1.2/50 s open circuit with 10/700μs( waveform generator output) Maximum voltage tested :6 kV Matching Resistance ...
|
|
|
|
Lightning surge generator1089 Series SUG 1089 series of products are made in accordance with the requirements of part 68 of the FCC of the Federal Communications Commission (FCC) ...
|
|
|
|
Lightning surge generator1089 Series SUG 1089 series of products are made in accordance with the requirements of part 68 of the FCC of the Federal Communications Commission (FCC) ...
|
|
|
|
Lightning surge generator1089 Series SUG 1089 series of products are made in accordance with the requirements of part 68 of the FCC of the Federal Communications Commission (FCC) ...
|
|
|
|
Power frequency magnetic field coil Compliance: IEC61000-4-8/9/10 Specification Type PFM-COIL PFM--108A PFM-210A PFM-210B Coil type Single Single Helmholtz coil Helmholtz coil ...
|
|
|
|
Pulse magnetic field generator PRM61009TG Pulse magnetic field generator is PFM61009TG a high reliability test instrument specially designed for the characteristics and requirement...
|
|
|
|
Damped oscillating magnetic field generator DMF61010 The damping oscillation wave magnetic field is simulated by the isolation knife gate in line with the high voltage busbar, ...
|
|
|
|
Damping shock wave generator SJB61012TG The oscillation wave of the equipment may affect the reliable operation of the equipment and the system. The ringing wave is caused by the ...
|
|
|
|
Ring wave generatorZLB61012T Series The oscillation wave of the equipment may affect the reliable operation of the equipment and the system. The ringing wave is caused by the ...
|
|
|
|
Peak voltage, over/under voltage generator SUG181A/B the SUG-181A spike voltage generator is designed according to the requirements of the GJB181 standard. during the flight of the ...
|
|
|
|
High frequency noise generatorPRM-24A/B High frequency noise analog generator PRM-24A used to evaluate the performance of electronic equipment against transient conduction ...
|
|
|
|
Test System for Conductive Harassment and Disturbance of RF Field Induction CRF61006A/B CRF61006A /B radio frequency conduction immunity test system, according to the IEC61000-4-6 ...
|
|
|
|
Cylindrical borosilicate glass vessel 190mm diameter, IEC 60335-2-25 test equipment 3.1.9 Replacement: normal operation operation of the appliance with 1 000 g ± 50 g of potable ...
|
|
|
|
Diameter 60mm Test Rod , EN 60335-2-30 Surfaces that are accessible to the test rod Product Description: 1. According To Standard: EN 60335-2-30 2. It is used to the protective ...
|
|
|
|
30K Air Conditioner Air Enthalpy Method Calorimeter Energy Efficiency Temperature Humidity Test Chamber For Household Charter 1 Laboratory General Introduction Outline This air ...
|
|
|
|
Apparatus for testing durability of markings on rating labels , IEC 60730-1-Figure 8 Technical parameters: Equipment Markings durability tester Test station 1 station Test stroke ...
|
|
|
|
IEC60745-2-5 Circular Saw Switch Endurance And Lower Guard Recovery Time Test Device Comply with standards: EN 60745-2-5: 2010 Annex M21.18, Annex M21.18.301, Annex M21.203, Annex ...
|
|
|
You may also be interested in :