60TPH RO Filtration System Water Purifier Desalination Plant

 

Reverse osmosis water system uses membrane separation technology to remove charged ions, inorganic substances, colloidal particles, bacteria and organic matter in water. It generally includes pretreatment system, reverse osmosis unit, post-treatment system, cleaning system and electrical control system. The purpose of pretreatment is to make the raw water meet the inlet requirements of the ro membrane separation unit and ensure the stable operation of the ro purification system. Reverse osmosis membrane system is the most economical and efficient purification method to remove more than 98% ions, organic matter and 100% microorganisms in raw water at one time. The ultra-purification post-treatment system further removes trace ions, organics and other impurities in the reverse osmosis pure water through a variety of integrated technologies, so as to meet the requirements of the final water quality index.

 

Technical specification of RO Water Treatment System

 

ModelJFRO-60T
Host Sizecan be customized
Power45KW
Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure1.2~1.5MPa
Recovery Rate70%
Designed Water Inlet85t/h
Outlet Flow60t/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size8040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes60
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
High Pressure PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP(Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingFRP
Number of Membrane housing10
Pipe MaterialU-PVC/ Stainless steel (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Composition of RO Water Treatment System

 

Reverse osmosis purified water treatment system generally includes pretreatment system, reverse osmosis device, post-treatment system, cleaning system and electrical control system.

 

1, the pretreatment system generally includes the original water pump, dosing device, quartz sand filter, activated carbon filter, precision filter, etc. Its main function is to reduce the pollution index of raw water and other impurities such as residual chlorine to meet the requirements of reverse osmosis inlet water.

2. Reverse osmosis device mainly consists of multistage high pressure pump, reverse osmosis membrane element, membrane shell (pressure vessel), bracket and so on. Its main function is to remove impurities in water, so that the water meets the requirements of use.

3. Post-treatment system is an additional configuration in the case that reverse osmosis cannot meet the requirements of outlet water. Mainly including negative bed, positive bed, mixed bed, sterilization, ultrafiltration and other one or more of the equipment.

4, cleaning system is mainly composed of cleaning water tank, cleaning water pump, precision filter. When the reverse osmosis system is polluted and the effluent index cannot meet the requirements, it is necessary to clean the reverse osmosis system to restore its efficacy.

5. Electrical control system is used to control the normal operation of the whole reverse osmosis system. Including instrument panel, control panel, all kinds of electrical protection, electrical control cabinet, etc.

 

Working Process of RO Water Treatment System

 

 

 

Characteristics of RO Water Treatment System

 

1. The system can be fully automatic continuous production of water.

2. No chemical regeneration, easy operation and maintenance.

3. The core components of reverse osmosis system are CNP pump and Vontron reverse osmosis membrane.

4. The pure water tank automatically opens when the water level is low, and the original water tank automatically closes when the water level is high.

5. The system will automatically wash the reverse osmosis membrane about 90s, reducing the membrane fouling speed.

6. Water pump water shortage protection and low pressure protection switch.

7. The conductivity monitor will continuously test the water quality online and display data.

8. The whole system adopts water flowmeter, pressure gauge, solenoid valve, regulating control valve, control panel.

9. Reverse osmosis controller makes the whole reverse osmosis system run automatically.

10. Easy control and maintenance.

 

Applications of RO Water Treatment System


1. Preparation of space water, purified water, distilled water, etc.
2. Alcohol manufacturing and water reduction.
3. Pre-preparation of water in medicine, electronics and other industries.
4. Concentration, separation, purification and preparation of water distribution in chemical process.
5. Desalination and soft water for boiler feed water; desalination of sea water and brackish water.
6. Water and wastewater treatment in papermaking, electroplating, printing and dyeing and other industries.

 

Photos of RO Water Treatment System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAQ:

 

1. What is the material of ro water treatment system membrane?

 

Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis

 

Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.

 

 

2. RO water treatment system configuration?

 

First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1

 

Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.

 

The arrangement of membrane components can be divided into series and parallel.

 

 

3. What is the shell film material and specification of ro water treatment system?

 

Material of membrane case: stainless steel and fiberglass (FRP)

 

Specification of membrane shell: four inch membrane shell 4040 (one core to four core)

 

8 inch membrane case 8040 (one to seven cores)

 

Water inlet: end water inlet, side water inlet

 

Hot Products

Water Reuse RO Water Treatment System 50TPH Water Filter System Reverse Osmosis System Product ...
Water Treatment Reverse Osmosis System Purifying Water Filtration Plant Unique characteristics of RO ...
One Stage Reverse Osmosis Filter System Drinking Water Treatment Plant Reverse osmosis water system ...
300TPH RO Water Treatment System For Power Plant Boiler Water Supply Reverse osmosis system (RO ...
60TPH RO Filtration System Water Purifier Desalination Plant Reverse osmosis water system uses ...
Mineral Water RO Water Treatment System 500LPH RO Filter Plant What contaminants will RO Water ...