250LPH Ro Water Treatment System Reverse Osmosis Filter Equipment
 
Introduction to reverse osmosis technology:
RO (Reverse Osmosis) reverse osmosis technology is the use of pressure gauge difference as the power of membrane separation and filtration technology, from the United States in the 1960s aerospace science and technology research, gradually transformed into civil, has been widely used in scientific research, medicine, food, beverage, seawater desalination and other fields. RO reverse osmosis membrane aperture is as small as nanometer (1 nanometer =10-9 meters), under a certain pressure, H2O molecules can pass through the RO membrane, and the inorganic salts, heavy metal ions, organic matter, colloids, bacteria, viruses and other impurities in the source water can not pass through the RO membrane, so that the pure water that can pass through and the concentrated water that cannot be strictly separated. The conductivity of pure water filtered by RO membrane is 5 s/cm, which meets the Level 3 water standard of national laboratory. After the atom-level ion exchange column cycle filtration, the effluent resistivity can reach 18.2M.cm, exceeding the national laboratory level 1 water standard (GB682-92).
 
RO Water Treatment System Specification
 

0.5m³/h Reverse Osmosis System
ModelJFRO-250L
Host Size800x600x1600mm (can be customized)
Power1.5KW
Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure0.8-1.2MPa
Recovery Rate50%
Designed Water Inlet1000L/h
Outlet Flow500L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes1
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP (Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingSS/FRP (Optional)
Pipe MaterialU-PVC, Stainless steel (Optional)

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
Flow Chart of RO Water Treatment System
Raw water pump → mechanical filter → activated carbon filter → Sodium ion exchanger → precision filter → high pressure pump → reverse osmosis → ozone sterilizer (UV)
 

 
 
Introduction to reverse osmosis technology:
RO (Reverse Osmosis) reverse osmosis technology is the use of pressure gauge difference as the power of membrane separation and filtration technology, from the United States in the 1960s aerospace science and technology research, gradually transformed into civil, has been widely used in scientific research, medicine, food, beverage, seawater desalination and other fields. RO reverse osmosis membrane aperture is as small as nanometer (1 nanometer =10-9 meters), under a certain pressure, H2O molecules can pass through the RO membrane, and the inorganic salts, heavy metal ions, organic matter, colloids, bacteria, viruses and other impurities in the source water can not pass through the RO membrane, so that the pure water that can pass through and the concentrated water that cannot be strictly separated.
 
Photos of RO Water Treatment System
 

 
Here's a guide to getting the best offer
1. What is the source water to be treated? Industrial wastewater, tap water, well water, groundwater or seawater? Is there a water quality analysis report for conductivity?
2. How much capacity water treatment system do you need? 1000 liters per hour, 5000 liters per hour or more?
3. What is the purpose of outputting purified water? Drinking water, food, beverage manufacturing, industrial use or medical production use?

 
 

 
 

 

 
 

 
 

 
 

 
 

 
FAQ:
 
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
 
Model 4040 is designed by 0.25m3/h
 
Model 8040 is designed by 1-1.2m3/h
 
2. What is the material of mechanical filter?
 
Carbon steel, stainless steel, fiberglass
 
3, what are the multi-way control valves?
 
Manual control valve, automatic control valve
 
Multi - way control valve is divided into: filter valve and softening valve
 
Automatic control valve is divided into: time type and flow type.
 
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.
 


















































































Hot Products

1TPH RO Water Treatment System FRP Pure Water Reverse Osmosis System Basic principle of reverse ...
100TPH RO Water Filter Equipment Purifying Water Filtration Plant Advantages of reverse osmosis ...
80TPH Water Purifier Reverse Osmosis System Waste Water Treatment Plant There are two ways to clean ...
Reverse Osmosis Water Purification Plant 500LPH Filtration System Single Stage Application fields of ...
250LPH Ro Water Treatment System Reverse Osmosis Filter Equipment Introduction to reverse osmosis ...
2TPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant Reverse osmosis preparation ...