Home Companies Jufu Water Technology Co., Ltd

Reverse Osmosis Water Filter System 1TPH Industrial Water Purifying Treatment Equipment

Jufu Water Technology Co., Ltd
Active Member

Contact Us

[China] country

Address: 15F, Block B, FRD International Wealth Center, Fengcheng 12th Road, Weiyang District, Xi’an,Shaanxi, China 710018

Contact name:Chloe Cheung

Inquir Now

Jufu Water Technology Co., Ltd

Reverse Osmosis Water Filter System 1TPH Industrial Water Purifying Treatment Equipment

Country/Region china
City & Province Shaanxi
Categories Water Treatment
InquireNow

Product Details

1TPH Reverse Osmosis Water Filter System Purifying Industrial Water Treatment Equipment


 The instrument (sensor) parameters of the reverse osmosis water treatment system must be calibrated every 3-6 months to ensure the accuracy of equipment parameters. Because of the difference of surface water sources, the types of operating problems of reverse osmosis equipment are not the same in different places. Therefore, users should carefully analyze the running status of their own system. Especially in the characteristics of membrane pollution and system cleaning should be explored according to the actual situation to find out the solution to the problem suitable for the system.

 

The Basic Working Principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to a pressure of 6-20 kg, the raw water permeates through the reverse osmosis membrane with a pore size of only 0.0001 microns under the action of pressure. Chemical ions, bacteria, fungi, and virions cannot pass through, and are discharged with wastewater. Only water molecules and solvents with a volume of less than 0.0001 microns are allowed to pass through.
 
Technical Specifications of RO Water Treatment System

1000LPH Reverse Osmosis System
ModelJFRO-1000L
Host Size

1000x600x1600mm (can be customized)

Power2.2KW
Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure0.8-1.2MPa
Recovery Rate50%
Designed Water Inlet2000L/h
Outlet Flow1000L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes4
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP (Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingSS/FRP (Optional)
Pipe MaterialU-PVC, Stainless steel (Optional)

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pretreatment dosing problem of reverse osmosis water treatment system

 

1. Dosing problems of flocculant and coagulant aid:

The turbidity of the source water, PH value, the content of iron ion and the type of drug added in the subsequent system determine the type and dosage of the flocculant and coagulant aid. And dosage must do adaptability and dosage optimization test. Many RO users in this aspect of the work is not in place, resulting in the clarification of the pool water quality is not good.

 

2. The dosing problem of fungicides

For organic matter and bacteria and microorganisms in raw water, the user usually uses oxidizing media to kill, such as sodium hypochlorite, liquid chlorine, chlorine dioxide, etc. For some surface water sources, the bactericidal effect is not ideal due to the long-term addition of the above medium. At present, non-oxidizing fungicides, such as ZDH-881 and MDC-881, have longer killing effect, and can save the cost of subsequent reducing agent addition.

 

3. The addition of reducing agent

The addition of reducing agent should take into account the thoroughness of the reduction effect and the bacterial contamination after excessive addition. It is often found that after the user adds too much, the bacterial slime on the filter element is generated.

 
Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.
 

 
Photos of reverse osmosis water treatment system


 

 

 

 

 

FAQ:
 
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
 
Model 4040 is designed by 0.25m3/h
 
Model 8040 is designed by 1-1.2m3/h
 
2. What is the material of mechanical filter?
 
Carbon steel, stainless steel, fiberglass
 
3.What are the multi-way control valves?
 
Manual control valve, automatic control valve
 
Multi - way control valve is divided into: filter valve and softening valve
 
Automatic control valve is divided into: time type and flow type.
 
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.

Hot Products

2TPH Reverse Osmosis Water Treatment Machine RO Water System Ro Water Equipment Advantages of ...
Reverse Osmosis 2TPH Water Treatment Machine RO Water System Desalination Ro Water Equipment ...
Mineral Water RO Water Treatment System 1000LPH RO Filter Plant Purified Water Machine Preparation ...
One Stage 1PH Water Purification Equipment RO Water Treatment System For Well Water Types of common ...
1TPH Reverse Osmosis Water Filter System Purifying Industrial Water Treatment Equipment The ...
1TPH RO Filter Plant Water Treatment System FRP Nitrate Removal Machine Preparation before operation ...