Home Companies Jufu Water Technology Co., Ltd

RO System Water Purification Plant Industrial Ro Plant 2.2KW

Jufu Water Technology Co., Ltd
Active Member

Contact Us

[China] country

Address: 15F, Block B, FRD International Wealth Center, Fengcheng 12th Road, Weiyang District, Xi’an,Shaanxi, China 710018

Contact name:Chloe Cheung

Inquir Now

Jufu Water Technology Co., Ltd

RO System Water Purification Plant Industrial Ro Plant 2.2KW

Country/Region china
City & Province Shaanxi
Categories Water Treatment
InquireNow

Product Details

RO System Water Purification Plant Industrial Ro Plant
 
Product Introduction of RO Water Treatment System
The latest development of reverse osmosis membrane
Due to the advantages of saving power consumption and reducing the pressure level of related mechanical parts, the ultra-low pressure membrane has been used in a growing proportion of applications since 1999, and it is mainly used in small devices that use 4-inch membranes. Most prominently, the application of ultra-low pressure membranes in large-scale devices is also on the rise. At present, the water production capacity of the largest device using ultra-low pressure membranes is 650 tons/hour. Low fouling membrane Membrane fouling is the greatest hazard in reverse osmosis applications. At present, several low-pollution membranes with strong anti-pollution performance, long service life, low cleaning frequency and easy cleaning have come out.
High temperature resistant, food grade, sanitary grade reverse osmosis membrane The operating temperature of reverse osmosis membranes for ordinary water treatment is 0-45 degrees Celsius, but in special occasions that require high temperature sterilization at 90 degrees Celsius, high temperature resistant and chemical resistant reverse osmosis membranes can be used. permeable membrane. In addition, various food-grade or sanitary-grade reverse osmosis membranes with special membrane element structures have also begun to be used in China.

 

The Basic Working Principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to a pressure of 6-20 kg, the raw water permeates through the reverse osmosis membrane with a pore size of only 0.0001 microns under the action of pressure. Chemical ions, bacteria, fungi, and virions cannot pass through, and are discharged with wastewater. Only water molecules and solvents with a volume of less than 0.0001 microns are allowed to pass through.
 
Technical Specifications of RO Water Treatment System

1000LPH Reverse Osmosis System
ModelJFRO-1000L
Host Size

1000x600x1600mm (can be customized)

Power2.2KW
Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure0.8-1.2MPa
Recovery Rate50%
Designed Water Inlet2000L/h
Outlet Flow1000L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes4
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP (Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingSS/FRP (Optional)
Pipe MaterialU-PVC, Stainless steel (Optional)

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Advantages of RO water treatment system:
Reverse osmosis equipment belongs to physical desalting method, which has many advantages.
1) Non-phase-change physical method was used to desalinate and purify the saline water under norma temperature.
2) Desalting rate of single membrane element is 99.3% and can remove colloid, organics, bacteria, virus and all kinds of heavy metals in water at the same time.
3) With water pressure as the driving force, energy consumption is the lowest among many treatment methods.
4) No need for large amount of chemical treatment, no elimination of chemical waste liquid, no environmental pollution, and the recovery rate is over 70%.
5) High automation program, automatic stop in case of ailure, with automatic protection function.
6) The system is simple, easy to operate, and the water quality is stable.
7) Equipment covers small area, compact structure, reliable operation and high water quality.
 
Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.
 

 
Photos of Reverse Osmosis Water Treatment System


Demonstration of the application of reverse osmosis system

Replacement of consumables

Products you may be interested in


 

 

 

FAQ:
 
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
 
Model 4040 is designed by 0.25m3/h
 
Model 8040 is designed by 1-1.2m3/h
 
2. What is the material of mechanical filter?
 
Carbon steel, stainless steel, fiberglass
 
3.What are the multi-way control valves?
 
Manual control valve, automatic control valve
 
Multi - way control valve is divided into: filter valve and softening valve
 
Automatic control valve is divided into: time type and flow type.
 
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.

Hot Products

Desalination System With Pretreatment Water Softening System Product Introduction The Basic Working ...
1000LPH Purification Plant RO System Industrial Ro Plant Product Introduction of RO Water Treatment ...
Small Water Treatment Equipment For Industrial Water Treatment Product Introduction of RO Water ...
RO System Water Purification Plant 1000LPH Industrial Reverse Osmosis Water Purification Equipment ...
RO System Water Purification Plant Industrial Ro Plant Product Introduction of RO Water Treatment ...
Mini Industrial Reverse Osmosis Water Filter System Ro Water Purifier Product Introduction of RO ...