500LPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant
 
Product introduction of Ro Water Treatment System


When a pressure greater than the osmotic pressure is applied to the brine side of the membrane, the direction of water flow is reversed, and the water in the brine flows into the freshwater side, a phenomenon called reverse osmosis (reverse osmosis, abbreviated as RO). It is pretreated first and then treated with RO. Through these treatments, 99% of dissolved salts and harmful substances such as particles, colloids, organic impurities, heavy metal ions, bacteria, viruses and heat sources can be removed. The desalination rate of the system reaches 96-98%, and the conductivity of the effluent is ≤ 10μ S/cm.
 
The Basic Working Principle of Ro Water Treatment System


After a special high-pressure pump, when the raw water is added to a pressure of 6-20 kg, the raw water permeates through the reverse osmosis membrane with a pore size of only 0.0001 microns under the action of pressure. Chemical ions, bacteria, fungi, and virions cannot pass through, and are discharged with wastewater. Only water molecules and solvents with a volume of less than 0.0001 microns are allowed to pass through.
 
Technical Specifications of Ro Water Treatment System

 

Model

JFRO-500L

Host Size

800x600x1600mm (can be customized)

Power

1.5KW

Power Supply

220V/380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure

0.8-1.2MPa

Recovery Rate

50%

Designed Water Inlet

1000L/h

Outlet Flow

500L/h

Desalination Rate

≥99.5%

RO Frame

SUS304

Membrane Size

4040

Membrane Elements

DOW /Hydranautics/Troy/ Vontron (Optional)

Number of Membranes

2

Raw Water Pump

CNP/NYP/GRUNDFOS (Optional)

Raw Water Pump

CNP/NYP/GRUNDFOS (Optional)

Tank Material

SS/FRP (Optional)

Control Valve

Manual/Automatic

Control Valve Brand

FLECK/RUNXIN

Membrane Housing

SS/FRP (Optional)

Pipe Material

U-PVC, Stainless steel (Optional)

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Application fields of Ro Water Treatment System
 
1. Purification of pure water, distilled water, food and beverage water.
2. Preparation of pure water ultra-pure water in electronics, medicine, food and other industries.
3. Process engineering for separation, concentration and liquid decolorization in light textile, chemical and food industries.
4. Desalination of seawater and brackish water.
 
Features of Ro Water Treatment System
 
(1) The reaction rate is fast and the processing time is short.
(2) It has a wide range of applications, and has a good treatment effect on refractory organic compounds containing azo, carbon double bonds, nitro, and halogenated structures.
(3) The process is simple, the service life is long, the operating cost is low, the operation and maintenance are convenient, and the treatment effect is stable.
(4) The removal rate of chromaticity and COD is high, and the biodegradability of RO concentrated water is improved.

 
Process flow of Ro Water Treatment System


Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.
 


 
Photos and details of Ro Water Treatment System

 

 
Here's a guide to getting the best offer


1. What is the source water to be treated? Industrial wastewater, tap water, well water, groundwater or seawater? Is there a water quality analysis report for conductivity?
2. How much capacity water treatment system do you need? 1000 liters per hour, 5000 liters per hour or more?
3. What is the purpose of outputting purified water? Drinking water, food, beverage manufacturing, industrial use or medical production use?

 
 

 

 

 

 

 

 

 

 

FAQ:
 
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
 
Model 4040 is designed by 0.25m3/h
 
Model 8040 is designed by 1-1.2m3/h
 
2. What is the material of mechanical filter?
 
Carbon steel, stainless steel, fiberglass
 
3. What are the multi-way control valves?
 
Manual control valve, automatic control valve
 
Multi - way control valve is divided into: filter valve and softening valve
 
Automatic control valve is divided into: time type and flow type.
 
Multi-way control valve brands are: FLECK, AUTOTROL
, Runxin, clean source, etc.

Hot Products

10TPH Reverse Osmosis Filter System Waste Water Treatment Plant Definition of RO water treatment ...
One Stage RO Water Treatment Equipment Water Desalination Plant What is Reverse Osmosis Water ...
50TPH RO Water Purification Plant Reverse Osmosis Water Treatment System Ro Water Treatment System ...
40TPH One Stage RO Water Treatment Plant Water Purifier Machine Reverse osmosis (RO) system is a ...
500LPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant Product introduction of ...
Reverse Osmosis Water Treatment Plant Water Purification System What is RO Water Treatment System? ...