500LPH One Stage Drinking Water Reverse Osmosis System Water Purification Plant

 

What are the types of membranes for drinking water ro systems?

 

1. Cellulose acetate reverse osmosis membrane. Cellulose acetate is also called acetyl cellulose or cellulose acetate. Cellulose acetate is usually obtained from cotton and wood containing cellulose through esterification and hydrolysis, and then processed into reverse osmosis membrane.

2. Composite reverse osmosis membrane. The composite reverse osmosis membrane is mainly composed of the above two materials, consisting of a thin dense layer and porous support layer. The porous support layer, also known as the base membrane, enhances mechanical strength. The dense layer, also called the epidermis, plays a role in desalting, so it is also called the desalting layer. The thickness of seawater desalination layer is generally 50nm, and the thinnest is 30nm.

3. Polyamide reverse osmosis membrane. Polyamides include aliphatic and aromatic polyamides. The main applications in the 1970s were aliphatic polyamides, such as nylon-4, Nylon-6 and Nylon-66 membranes.

 

Since the pore size of the RO membrane is one millionth of the hair (0.0001 micron), it is generally invisible to the naked eye, and bacteria and viruses are 5000 times larger than it. Therefore, only water molecules and some mineral ions can pass through (the ions that pass through) No profit or loss orientation), other impurities and heavy metals are discharged from the waste water pipe.

 

Technical specifications for reverse osmosis systems for drinking water:

 

0.5m³/h Reverse Osmosis System
ModelJFRO-500L
Host Size800x600x1600mm (can be customized)
Power1.5KW
Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure0.8-1.2MPa
Recovery Rate50%
Designed Water Inlet1000L/h
Outlet Flow500L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes2
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP (Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingSS/FRP (Optional)
Pipe MaterialU-PVC, Stainless steel (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drinking water RO system work flow chart:

 

Cleaning of reverse osmosis membranes

 

A. Cleaning method Dilute the cleaning agent to a certain concentration and pump it into the membrane module for cleaning. In the case of serious pollution, the method of soaking overnight can be used, but the time should not be too long; the contact time between the chemical agent and the membrane should be minimized.
B. Calcium carbonate scale Reduce the pH value of the feed water to between 3.0 and 5.0, and run for 1 to 2 hours.
C. Calcium sulfate scale The best way to remove the scale is to use 7.7kg of sodium tripolyphosphate, 3.18kg of sodium EDTA, and 379kg of reverse osmosis product water, and adjust the pH value to 10.0 with sulfuric acid.
D. Metal oxide scale is removed by the method of removing calcium carbonate scale.
E. Organic sediments can be removed with 7.7kg of sodium tripolyphosphate, 0.97kg of sodium dodecylbenzene sulfonate, 379L of reverse osmosis product water, and the pH value is adjusted to 10.0 with sulfuric acid. If the pollution is serious, this solution can be soaked for 12 hours.

 

 

 

 

 

 

 

 

 

 

FAQ:

 

1. What is the shell film material and specification of drinking water reverse osmosis system?

Material of membrane case: stainless steel and fiberglass (FRP)
Specification of membrane shell: four inch membrane shell 4040 (one core to four core)
8 inch membrane case 8040 (one to seven cores)

 

2. What are the inlet water quality requirements of drinking water reverse osmosis system?

Inlet water quality requirements:
Turbidity (NTU) ≤1, SDI ≤5 Residual chlorine (mg/L) ≤0.1, Fe2+ (mg/L) ≤4, TOC (mg/L) ≤3

 

Hot Products

Membrane Bioreactor Wastewater Treatment Plant for Municipal Waste Water Product Description of ...
Drinking Water RO System one-Stage RO FRP 500LPH For Pure water Drinking water RO system mechanism ...
1000LPH Drinking Water RO System Reverse Osmosis For Bottled Pure Water Separation capacity of ...
500LPH SS304 Drinking Water RO System Two-Stage Reverse Osmosis Plant There are three main types of ...
500LPH One Stage Drinking Water Reverse Osmosis System Water Purification Plant What are the types ...
500LPH Dringking Water RO System One-Stage RO System SUS304 For Pure Water The working principle of ...