Mineral Water RO Water Treatment System 1000LPH RO Filter Plant Purified Water Machine

 

Preparation before operation of reverse osmosis water treatment equipment:


RO as a high pressure operation equipment, before operation, in order to protect the equipment and instrument and safety, it is necessary to confirm and adjust the opening state of the valve strictly in accordance with the operating procedures. The specific operations are as follows:


1. Completely open the water inlet valve of the security filter and open the water inlet valve of the high pressure pump
2. Open the high-pressure pump outlet valve for a circle
3. Open the RO inlet valve for one turn
4. Rotate the needle valve on the concentrated water pipe three and a half turns
5, fully open the water production outlet valve and concentrated water outlet valve
6. Close all sampling valves and cleaning valves
7. Open all pressure display valves to half open state

 

Components and Principles of RO Water Treatment System


The reverse osmosis system includes high pressure pump, reverse osmosis membrane element, pressure vessel (membrane shell), cleaning system and control instrument; the principle of reverse osmosis water treatment system is: when a pressure greater than osmotic pressure is applied on the brine side of the membrane, the water The direction of flow will be reversed, and the water in the brine will flow into the fresh water side, a phenomenon called reverse osmosis.

 

Technical Specifications of RO Water Treatment System

 

ModelJFRO-1000L
Host Size1000x600x1600mm (can be customized)
Power2.2KW
Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure0.8~1.2MPa
Recovery Rate50%
Designed Water Inlet2000L/h
Outlet Flow1000L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes4
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
High Pressure PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP(Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingFRP
Pipe Material

U-PVC/ Stainless steel (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Classical mechanism model of reverse osmosis water treatment system:


1. Preferential adsorption model of capillary pores: no pores were found under the dry electron microscope of weak spot. Wet membrane specimens are not electron microscope samples.
2. Dissolution and diffusion model: Pores are not considered.
3. Dry-closed and wet-open model: the "dry-closed and wet-open" reverse osmosis model unifies the two most classical reverse osmosis mechanism models, namely, the fine-hole model and the solution-diffusion model.

 

 

Process flow of RO Water Treatment System

 

Original water pump → mechanical filter (quartz sand filter)→ activated carbon filter → sodium ion exchanger (water softener)→ security filter → high pressure pump → reverse osmosis → ozone sterilizer (ultraviolet sterilizer)

 

 

Photos and details of RO Water Treatment System

 

 

 

Stainless steel membrane shell of RO Water Treatment System

 

 

FRP membrane shell for RO Water Treatment System

 

 

 

 

 

 

 

 

FAQ:

 

1. What is the shell film material and specification of ro water treatment system?

 

Material of membrane case: stainless steel and fiberglass (FRP)

 

Specification of membrane shell: four inch membrane shell 4040 (one core to four core)

 

8 inch membrane case 8040 (one to seven cores)

 

Water inlet: end water inlet, side water inlet

 

2. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)

 

Model 4040 is designed by 0.25m3/h

 

Model 8040 is designed by 1-1.2m3/h

 

3. What is the material of mechanical filter?

 

Carbon steel, stainless steel, fiberglass

 

 

Hot Products

Mineral Water RO Water Treatment System 1000LPH RO Filter Plant Purified Water Machine Preparation ...
One Stage 1PH Water Purification Equipment RO Water Treatment System For Well Water Types of common ...
1TPH Reverse Osmosis Water Filter System Purifying Industrial Water Treatment Equipment The ...
1TPH RO Filter Plant Water Treatment System FRP Nitrate Removal Machine Preparation before operation ...
1000LPH Water Treatment Plant RO Reverse Osmosis System Electrodeionization EDI Product Introduction ...
1000LPH RO Water Softener Treatment System Water Purification Plant Reverse osmosis membrane ...