V-Type Copper Tube Dry Type Air Cooler For Immersion Cooling System

 

What is closed-loop dry cooling system?

 

The strength of a closed-loop dry cooling system is that the unit is very simple and relatively easy to install. The energy requirements are relatively low and it is easily controlled. Maintenance is normally low requiring only periodic inspection, lubrication, and testing of the fluid.

 

The weakness of a closed-loop dry cooling system is that it is dependent on the atmospheric dry bulb. For example, if your location’s design dry bulb is 100 F in the summer and your equipment requires 90 F coolant; at best the system can only supply around 105 to 110 F coolant to the load. In this case you would need supplemental cooling to get the coolant temperatures down to 90 F.

 

The closed-loop dry cooling system also requires free clear air to work efficiently. This means that the fluid cooler must be placed in a location that is not affected by the prevailing winds, not too close to a building that will allow the warm exhaust air from the fluid cooler to be recirculated back to the fluid cooler, and finally not in a location that has heavy concentrations of dust, dirt, leaves, seeds, etc.

 

Many times the best location for the fluid cooler is on the roof. Since the fluid cooler is located outside the coolant must also have a concentration of some type of glycol to prevent freezing if your location has a design dry bulb in the winter that dips below freezing. If the location is very cold, the concentration of glycol may need to be significant to prevent freezing. Glycol concentrations as they increase begin to reduce the rate of heat transfer. For example, if you need 50% ethylene glycol concentration with water the heat exchanger equipment and the flow/pressure of the coolant will need to increase to adjust for the glycol concentration. Larger fluid coolers and pumps will increase the cost of the system over those with lesser concentrations of Glycol/water. This cannot be prevented in colder climates.

 

Dry fluid cooler features:

Air discharge direction
Performance ranges

Cooling capacity: from 5 to 649 kw

Air volume: from 2828 to 263503 m3/h

Sound pressure level: from 31 to 69 dB A(10m)

Dry coolers:customized on demand

High efficiency heat exchanger

Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.

Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).

Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

Fan

Only choose low specific energy consumption fans.

Fan nozzle designs for maximum air flow and air throw.

Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.

Motor: protection class IP 54 and insulation class F.

Voltage:400V/3N/50Hz

Air separator for each fan.

TestingHeat exchangers are supplied clean and tested at a pressure of 30 bars
Options

Coil design refrigerant: water, oil, glycol.

Multiple circuits.

Sub-cooling circuits.

Stainless steel or aluminum casing.

Coated aluminum or copper fins.

Explosion ploof motor.

Customized fin spacing.

 

 

Dry fluid cooler technical parameter

Dry cooler D1 series parameter(fin space 2.1mm)

Type

D1-166-

4x630

D1-211-

6x630

D1-247-

6x630

D1-286-

8x630

D1-334-

8x630

D1-360-

10x630

D1-415-

10x630

D1-502-

12x630

D1-565-

14x630

D1-649-

16x630

CapacityWater35℃ outdoor temp.Inlet45℃,KW165.92211.36247.3286.15334.49359.72415.31502.25565.18649.48
outlet40℃Y134.59176.00200.45238.3270.889298.57335.225405.20459.3527.59
20% GlycolInlet45℃161.32205.08240.46280.05327.72351.3406.48493.40554.21638.44
outlet40℃Y130.96170.87195.07233.18265.64291.81328.48398.45450.87519.13
MediumWater flowM3/h29.003743505863728898113
Pressure dropkPa50704797959270979695
Air flowM3/h67455109723101185146293134908179502164442197326230584263503
Y512658366176900111544102528136437124680149612174710199665
Fan motorPhase3333333333
W1100165001650022000220002750027500330003850044000
Y700105001050014000140001750017500210002450028000
A20.430.630.640.840.851.0051.0061.2071.4081.60
Y12.0018.0018.0024.0024.0030.0030.0036.0042.0048.00
FanNo X φ

2X2

X630

2x3

x630

2x3

x630

2x4

x630

2x4

x630

2x5

x630

2x5

x630

2x6

x630

2x7

x630

2x8

x630

Sound pressure leveldB(A)64666667676868686969
Y10m57595960606161616262
DimensionLmm29304230423055305530683068308130943010730
Wmm2100210021002100210021002100210021002100
Hmm1070107010701070107011201120112011201120
Amm--------------------
Bmm1340134013401340134013401340134013401340
Cmm1300130013001300130013001300130013001300
Dmm640640640640640640640640640640
Inlet φmm3”3”3”DN100DN100DN100DN125DN125

2X

DN125

2X

DN125

Inlet φmm3”3”3”DN100DN100DN100DN125DN125

2X

DN125

2X

DN125

Product weight(empty)kg6586897601105127013201420158418482112

 

Application:

Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, sloar system, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.

 

How to design a dry cooler?

 

Tell Shenglin the datas as following:
A. Required electrolyte inlet temperature?
B. Required electrolyte​ outlet temperature?
C. Electrolyte​ flow?
D. Ambient temperature?
E. Supply power(voltage-Hz-phase)
G. Any other requirements ?

 

Reference:

For solar industryCountry: China
Application :cooling of solar heating system when it is overheated
Cooling capacity: 463, 933 and 1475kW
Cooling medium: 50% propylene glycol water
Supply power: 380V/3P/50Hz
Fan brand: Ziehl-Abegg
Altitude:4200m
Country: UAE
Application: solar thermal system
Cooling capacity: 21kw
Cooling medium: water
Supply power: 230V/1P/50Hz
Fan brand: Chinese brand
Country: Korea
Application: solar system overheated
Cooling capacity: 32kW
Cooling medium: 30% ethylene glycol water
Supply power: 230V/1P/60Hz
Fan brand: Chinese brand
 
For plastic industryCountry: Algeria
Application: cooling water from injection molding machine
Cooling capacity: 694kW
Cooling medium: water
Supply power: 400V/3P/50Hz
Fan brand: Ziehl-Abegg
Country: Armenia
Application: for plastic caps of beverages factory
Cooling capacity:70kW
Cooling medium: 34% ethylene glycol
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand
Country: Russia
Application: bathtub factory
Inlet/outlet air temperature:40℃/66℃
Inlet/outlet water temperature:85℃/50℃
Air volume:7986m3/h
Cooling medium:water
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand
Instead of cooling towerCountry: Argentina
Application: for equipment cooling, to match chiller.
Cooling capacity: 245kW
Cooling medium: water
Supply power:380V/3P/50Hz
Fan brand: Chinese brand


 
Country: Peru
Application: instead of cooling tower, to match chiller.
Cooling capacity: 360kW
Cooling medium: water
Supply power:440V/3P/60Hz
Fan brand: Chinese brand
With wet curtain, with water pump and water tank
 
Country: Mauritius
Application: supermarket and will match chiller use.
Heat transfer capacity: 502kW
Cooling medium: water
Inlet air temp.: 32℃
Inlet medium temp.: 42℃
Outlet medium temp.: 37℃
Medium volume: 88m3/h
Material: copper tube aluminum fin and galvanized steel frame, RAL9010 powder coating.
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand, air volume: 20228m3/h
For data center coolingCountry: Mongolia
Application: match with precision air conditioner
Cooling capacity: 17.6kW
Cooling medium: 34% ethylene glycol
Supply power: 400V/3P/50Hz
Fan brand: Ziehl-Abegg
Country: Russia
Application:data center cooling
Cooling capacity: 763kW
Cooling medium: water
Supply power: 380V/3P/50Hz
Fan brand: Ziehl-Abegg
Factory coolingCountry: Russia
Application: ore yard cooling
Cooling capacity: 493kW
Cooling medium: 20% ethylene glycol
Supply power: 400V/3P/50Hz
Fan brand: Ziehl-Abegg
Country: China
Application: plant cooling
Cooling capacity: 52kW
Cooling medium: 30% ethylene glycol
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand
For power plantCountry: Hongkong
Application: power plant
Cooling capacity: 363kW
Cooling medium: water
Supply power: 415V/3P/50Hz
Fan brand: Chinese brand
Country: Russia
Application: power plant.
Cooling capacity: 180kW
Cooling medium: water
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand
Other applicationCountry: Singapore
Application: match with fruit and vegerable freezer
Cooling capacity: 14.6kw, 17kw and 29.37kw
Cooling medium: 20% ethylene glycol
Supply power: 230V/1P/50Hz
Fan brand: Ziehl-Abegg
Country: Singapore
Application: wastewater treatment factory, cooling water
Cooling capacity: 429kW
Cooling medium: water
Supply power: 400V/3P/50Hz
Fan brand: Ziehl-Abegg
Country: Russia
Application: industrial cooling
Cooling capacity: 153kW
Cooling medium: 20% glycol
Supply power: 380V/3P/50Hz
Fan brand: Ziehl-Abegg

Hot Products

Rooftop Fresh High Efficiency Duct Type Rooftop Air Conditioner For Whole Sales Capacity: 120~300kw, ...
High Safety Level Standard Rooftop HVAC Units Heat Recovery Type Rooftop Package Units​ Description: ...
R410a Rooftop Package Central Air Conditioner Rooftop Freezer Units Description: 1. Cooling capacity...
CE Approved Central Air Conditioner System Roof Mounted Ac Package Unit Main Features A. Efficient ...
Rooftop Package Unit Roof Top Air Conditioner Central Air Conditioning Boats Rooftop Aircon HVAC ...
Factory Price Adiabatic Water Spray System Epoxy Aluminum Fin Dry Fluid Cooler​ Features Our range ...