Home Companies Shanghai Shenglin M&E Technology Co., Ltd.

Heat Recovery Type Rooftop HVAC Package Units Scroll Type Compressor

Shanghai Shenglin M&E Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: Room B321, Building No.1, No. 619, Longchang Road, Yangpu District, Shanghai,China

Contact name:Jason

Inquir Now

Shanghai Shenglin M&E Technology Co., Ltd.

Heat Recovery Type Rooftop HVAC Package Units Scroll Type Compressor

Country/Region china
City & Province shanghai shanghai
InquireNow

Product Details

High Safety Level Standard Rooftop HVAC Units Heat Recovery Type Rooftop Package Units​

 

Description:
1. Cooling capacity: 120kw to 250kw, a variety of choices.
2. High external pressure.
3. Applicable to residential and commercial buildings, hotels, and scientific research units, factories and enterprises and so on.
 

Feature 1

1. Evaporator: Type Inner grooved copper tube and aluminum fin

2. Fin Type 5* :Slotted fin hydrophilic aluminum fin

3. Condenser: Type Inner grooved copper tube and aluminum fin

4. Fin Type 5* :Rippled hydrophilic aluminum fin

5. Condenser Fan Type: Low noise axial type

 

The unit has its cold and heat source and is air-cooled direct evaporative air-conditioning equipment. The entire air-conditioning system is only composed of an outdoor host and an indoor air duct. No cooling water and chilled water systems are required. It is easy to install and use, suitable for water-scarce areas.

The unit is designed for open-air installation on the roof or outdoor open space. It has the performance of anti-sun exposure, anti-corrosion, anti-torrential rain, etc., which can save the cost of air conditioning machine room and civil engineering.

Both the evaporator and condenser adopt enhanced heat transfer technology, which is highly efficient and energy-saving; the main parts are all imported high-quality products with excellent performance.

The unit has various air treatment functions, which can easily realize various functions such as air purification, dehumidification, humidification, refrigeration, and heating.


Feature 2

A. Efficient OperationOur packaged rooftop units cut energy costs significantly while meeting all applicable code compliance requirements.
B. Simplified InstallationEmbedded Smart Equipment and thoughtful design features make installation, start-up and commissioning faster and more accurate.
C. Integrated Flexibility

Field-installed accessories and an array of heating and air conditioning options help meet the needs of more applications.

 

 

Technical paramater:
Model:SL-WKR-()-HR120150180200250
Cooling capacity1*kW126.0(46.9)151.0(57.8)178.0(65.5)203.0(74.3)249.2(90.9)
Heating capacity2*kW138.6(51.6)162.0(63.5)190.3(72.0)223.3(81.7)271.9(96.4)
Supply fan 3*Type-Centrifugal
Air volumem³/h1200015000170001950024000
Static PressurePa400400400400450
Motor powerkW5.55.57.57.511.0
Exhaust fan 3*Type-Centrifugal
Air volumem³/h1200015000170001950024000
Static PressurePa400400400400450
Motor powerkW5.55.57.57.511.0
Supply power-3N-380V-50Hz
Input power 3*kW35.340.647.253.265.4
Heat recovery wheelType-Full heat recovery wheel
Wheel heat recovery efficiency%69.265.068.268.165.0
Temperature recovery efficiency%71.570.570.570.467.4
Compressor 4*Type 3*-Hermetic Scroll
PowerkW5.7*46.8*47.5*49*410.1*4
RefrigerantType -R22/R407C/R410A
Manner-External balance type thermal expansion value/Electronic expansion value
humidifier 5*Type-Wet film
Humidificationkg/h50.070.080.0100.0120.0
Noise 6*dB(A)6769697578
Filter-Initial effect G4(Middle effect F8/Nanocrystalline carbon filter)
Drain pipe-DN32DN32DN32DN40DN40
Overall dimensionsLength(mm)58005800580058005800
Width(mm)25502550255025502550
Height(mm)27452745274527452745
Unit weightkg35003810413043904560

1. Cooling condition: Indoor dry bulb/wet bulb: 35/24℃,Outdoor dry bulb/wet bulb: 27/19℃

2. Heating condition:Indoor dry bulb/wet bulb: 7/6℃;outdoor dry bulb/wet bulb:20/13.8℃;

3. The air volume and static pressure`s specification in the table is standard, and can be designable.

4. The inverter compressor system can be used to achieve more precise capacity control;
5. Heaters, humidifiers, hot and cold water coils are optional parts, and specific forms can be configured according to customer site requirements;
6. The noise is measured at a height of 1.2m and 2m directly in front of the unit when cooling under standard air volume;
7. The unit adopts a runner heat recovery device, and can be equipped with plate heat recovery and heat pipe heat recovery devices according to customer site requirements.
8. The fresh air unit is limited to processing fresh air, indoor temperature control and main load bearing must be handled by standard air conditioning equipment.

 

Reference:

Application: Rolling bearing manufacturer
Type: wheel heat recovery type
Cooling capacity: 95kw
Condensation and heating capacity: 55kw
Supply air volume: 19000m3/h
Exhaust air volume: 19000m3/h
Application:Ferry waiting hall
Type: heat pump type
Cooling capacity:182.5kw
Supply air volume: 22000m3/h
Application: Cool Storehouse
Type: constant temperature and constant humidity unit
Cooling capacity: 22kW
Electric heating capacity: 82kW
Humidifying capacity: 6kg/h
Supply air: 4500 m3/h

Hot Products

Rooftop Fresh High Efficiency Duct Type Rooftop Air Conditioner For Whole Sales Capacity: 120~300kw, ...
High Safety Level Standard Rooftop HVAC Units Heat Recovery Type Rooftop Package Units​ Description: ...
R410a Rooftop Package Central Air Conditioner Rooftop Freezer Units Description: 1. Cooling capacity...
CE Approved Central Air Conditioner System Roof Mounted Ac Package Unit Main Features A. Efficient ...
Rooftop Package Unit Roof Top Air Conditioner Central Air Conditioning Boats Rooftop Aircon HVAC ...
Air Cooled Heat Exchanger Flat Series Air Dry Coolers for Industrial Process Cooling Features High...