Air To Water Heat Pump For Swimming Pool


Features:


PVC Titaninm tube heat exchanger will full resistance against corrosion, more durable. Compact structure, easy demountable for access. High efficiency compressor, saving energy. Flow switch for water flow protection. Intelligent controller and adjustment by quick mind microprocessor. Intelligent LCD display wired controller. Air heat exchanger(fins-coil) with hydrophilic coating. Automatically defrosting function included.

Optional:

Galvanized metal cabinet or stainless steel cabinet.
Refrigerant: R22, R407C and R410A is available
Titaninm tube heat exchanger/stainless steel heat exchanger.


Technical paramater:

 

Commercial Swimming Pool Heat Pump
MODELKFXY-010UMIKFXY-018UMIIKFXY-023UMIIKFXY-036UMIIKFXY-045UMIIKFXY-070UMIIKFXY-090UMII
Heating mode/CirculatingCirculatingCirculatingCirculatingCirculatingCirculatingCirculating
Ambient temp. range-15~+43℃-15~+43℃-15~+43℃-15~+43℃-15~+43℃-15~+43℃-15~+43℃
Rated heating capacityKW11192338457090
COPW/W5.25.25.45.25.45.25.4
Rated power inputKW2.123.654.257.318.313.4616.7
Max. running currentA101314.513.06265048
Power supply/220V/50Hz380V 3N~50Hz380V 3N~50Hz380V 3N~50Hz380V 3N~50Hz380V 3N~50Hz380V 3N~50Hz
IP code/IPX4IPX4IPX4IPX4IPX4IPX4IPX4
Safety function/High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc.High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc.High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc.High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc.High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc.High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc.High and low voltage protection; Overload protection; Temperature protection; Power phase sequence protection, etc.
Refrigerant type-/kgR410a/1.4R410a/2.7R410a/3.0R410a/2.5×2R410a/3.0×2R410a/5×2R410a/7.5×2
Compressor QTYPCS1112222
Compressor type/ScrollScrollScrollScrollScrollScrollScroll
Max. temp. outlet water40404040404040
Water side heat exchanger type/Titanium tube heat exchangerTitanium tube heat exchangerTitanium tube heat exchangerTitanium tube heat exchangerTitanium tube heat exchangerTitanium tube heat exchangerTitanium tube heat exchanger
Air side heat exchanger type/Finned heat exchangerFinned heat exchangerFinned heat exchangerFinned heat exchangerFinned heat exchangerFinned heat exchangerFinned heat exchanger
Circulating waterpipe nozzleinchG1''G1.5''G1.5''G1.5''G1.5''G2''G2''
Outlet nozzleinchG1''G1.5''G1.5''G1.5''G1.5''G2''G2''
Circulating water volumem3/h4.738.179.89 19 39
Air out type/VerticalVerticalVerticalVerticalVerticalVerticalVertical
Fan motor QTYPCS1112232
NoisedB/(A)56565659686869
Machine dimension (WxDxH)mm750×690×870750×690×1070820×790×10801500×690×10701500×690×13802095×1005×18552095×1005×1855
Packing Dimension (WxDxH)mm800×740×1000800×740×1200920×840×12101580×800×12001580×740×15502195×1105×19552195×1105×1955
Net Weightkg110130150230330700800
Gross Weightkg130160170260360750850
Remarks:
1. Test conditions: (DB/WB)20℃/15℃,inlet water temperature 26°C, outlet water temperature 28°C.
2. Due to product improvement, above datas are subject to change without priop notice, please take the rating plate as standard
3. This water heat pump system is only suitable for city water that meets the national standard, such as ground water, well water, etc., which is not covered by the warranty. If the water quality is poor, please install a filter and water processor.

 

Application:

Packing:

 


 

 

Reference:

 

Country: Taiwan,China, middle school
Model: KFXR-018 UII,KFXR-045UII
Application: Domestic hot water
Country: Taiwan,China,residential building
Model: KFXR-036UII,KFXR-900UII
Application: Domestic hot water
Country: Beijing, China
Model: KFXF-180 UII
Application: Breeding heating
Country: Yunan, China
Model: /
Application: Aloe drying

 

 

Schematic diagram:


 
 

Hot Products

R407C -5 ℃ Single Compressor Water Cooled Water Chiller Products Features World famous brand screw ...
Packaged Rooftop Air Conditioning Units With Purification Function Feature: 1. Filter: G4+F7+F11+FFU...
CE Certification Rooftop HVAC Unit For Shopping Mall Air Conditioning System Description: 1. Air ...
Rooftop Fresh High Efficiency Duct Type Rooftop Air Conditioner For Whole Sales Capacity: 120~300kw, ...
High Safety Level Standard Rooftop HVAC Units Heat Recovery Type Rooftop Package Units​ Description: ...
R410a Rooftop Package Central Air Conditioner Rooftop Freezer Units Description: 1. Cooling capacity...