Hebei Kaixiang Electrical Technology Co., Ltd |
|
AC Dummy 1000KW Load Bank For Generator Testing China Brand Load
Bank
Product Description
Resistance/inductance/capacity Automatic load bank
Automatic AC load bank main used to test the capability and aging
degree for high-power ups on-line, inverter, switch power and
diesel generator set for electric power, telecom department and
manufacturer. It can ensure the reliability of constant power
charge that adopts uniformly stepped power input, energy
consumption work model and forced air-cooling model. It is of high
power density, no red hot phenomenon and automatic protection
function overheated. It can’t be overheated and broken when the
fans stop working. The complete machine can be operated simply and
maintain convenient that adopts module design. It can test voltage
and current according to client’s request, and provide scientific
test measures for high-power AC equipment.
Technical Parameters
Rating Voltage/Frequency | 400VAC/50Hz, 3 phase 4 wire, |
Rated Load Power | Resistive load: 1000kW |
Installed Capacity | Resistive load: 1000kW |
Load Step | 1,2,2,5,10,20,20,50,100,200,200,200,200kW, min step load: 1kW |
PF(Power Factor) | 1 |
Load Tolerance (each step) | ±5% |
Load Tolerance(overall) | ±3% |
Display Precision | 0.5 class |
Control Power | 380VAC/50Hz, 3 phase 4 wire, |
Wire Connection | Load power supply input——Copper bar (star coupling) |
Insulation | F |
Duty Cycle | Continuous |
Casing Dimensions and Cooling | about 1680*2400*1440mm (length*width*height) Forced air cooling,Horizontal inlet air,Horizontal outlet air |
Weight | About 1200kgs/set |
Transportation | Hoisting, there are lifting lug in top of casing |
Casing Color | Grey(RAL7035) |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Altitude | ≤1500 meter |
Atmospheric Pressure | 86~106kPa |
Contactor | Schneider |
Fuse | DELIXI |
MCU | INFINEON |
Data processing software | Kaixiang(self-developed) |
Alloy Resistance | Kaixiang(self-developed) |
Product Advantage
About resistor alloy, we use nickel-chromium alloy(NiCr6023) which
can withstand high temperature (Max operation temperature at
1,300℃), be of small temperature drift (5*10-5/℃) and steady
electrical performance.
Application
1.Manufacturers of small gas engines also use load banks to test
newly manufactured engines under various mechanical loads.
2.This is accomplished by connecting the engine to the load bank
via a device called a dynamometer.
3.engine performance is monitored and, if necessary, adjustments
are made to ensure the product performs within intended
specifications.