Product Details

Remote Control There Phase 20Kv 2200KW Medium Voltage Load Bank

 

Product Description

 

1. Automatic AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch power and diesel generator set for electric power, telecom department and manufacturer.

2. It can ensure the reliability of constant power charge that adopts uniformly stepped power input, energy consumption work model and forced air-cooling model.

3. It is of high power density, no red hot phenomenon and automatic protection function overheated.

 

Technical Parameters

 

Rating Voltage/Frequency20kV/50Hz, 3 phase 3 wire
Rated power2000kw
Load Resolution400KW.800KW.800KW
PF(Power Factor)1
Load Tolerance (each step)±5%
Load Tolerance(overall)±3%
Display Precision0.5 class
Control Power380VAC/50Hz,
WeightAbout 15000kgs/set
Wire Connection

Load power supply input——Copper bar (star coupling)

Control power supply input——Connector-bar

Size9150*2438*2591mm

 

Technology Advantages 
 

1. Multiple control mode: (1) manual panel control (2) remote control (3)software control

2. Multiple display function: voltage, current, frequency, power factor, active power, reactive power, apparent power etc.

3. Multiple protection function: overvoltage, overcurrent, overheat, over low blowing rate, blower overheat, blower phase sequence reverse protection, smoke alarm etc.

4. Forced air cooling: industrial heavy duty fan, horizon air intake, upwards outlet, low noise.

 
Application

 

Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator

 

 

 

Hot Products

In Australia 10.5KV 1800KW Medium Voltage Load Bank For Generator Testing Product Description 1. our ...
Display Voltage And Current 10.5KV 2200KW Medium Voltage Load Bank Product Description 1. Supply ...
High Voltage Capacitor Tester 10.56KV 3KV 50MW Medium Voltage Load Bank Product Description load ...
High Voltage 3 Phase Capacitor Tester 10Kv 2200KW Medium Voltage Load Bank Product Description AC ...
Remote Control There Phase 20Kv 2200KW Medium Voltage Load Bank Product Description 1. Automatic AC ...
Remote Control 10.5KV 2000KW Medium Voltage Load Bank With Three Control Ways Product Description 1. ...