AC415V - 271kVA Dummy Load Bank In High Performance And Resistive Inductive

Introduction

Triumph load can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW. Resistive, inductive(reactive),capacitive or combined load banks can be customised for any application. They can be used for testing numerous sets in a workshop environment, or used for on-site commissioning, witness tests and proof trials.Tailor-made load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.

Application

AC415V - 271kVA Dummy Load Bank can be used in a wide variety of applications, such as

Ups system testing,Battery system testing,Load optimization in prime power applications

Factory testing of turbines,Factory testing of engine generator sets,To reduce wet stacking problems

Periodic excercising of stand-by engine generator sets

Technical specification

 

Technical Parameter
Rating voltage/frequency415VAC power 265kVA; 3 phase 4 wire, 50Hz, phase voltage 240VAC
Max Load PowerResistive 31kW; inductive 120kvar; capacitive 120kvar
Load Resolution

Resistive Load: 10 steps, 0.1, 0.2, 0.2, 0.5 1, 2, 2, 5, 10, 10kW

Inductive Load: 9 steps, 1, 2, 2, 5, 10, 10, 20, 20, 50kvar

Capacitive Load: 9 steps, 1, 2, 2, 5, 10, 10, 20, 20, 50kvar

Power Factor±0.2-1
Load Tolerance (resistive load)±5%
Load Tolerance (inductive load)±3%
Display MeterMultiple function meter
Fan Control PowerExternal power 380VAC 3 phase 4 wire, 50Hz, phase voltage 220VAC
Wire Connection

Load bank input——busbar (star coupling ”Y”)

Control power input——terminal block

Communication InterfaceRS232/ RS485
InsulationF
Way of WorkingContinuous Working
CoolingForced air cooling, horizontal inlet air and upwards exhaust cooling
TransportationHoisting, it has lifting eys in top of case and wheel castors in bottom
ColorAs customer’s requirements or as our design RAL 7035 gray
DimensionsAbout 2300*1250*1680mm (L*W*H)
WeightAbout 1500kgs
Operating Environment Parameter
Ambient Temperature-10℃~+40℃
Relative Humidity≤95%
Atmospheric Pressure86~106kPa
Used Placeindoor
 
Main features
Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.

Overvoltage Protection: the input load voltage is over the safe threshold value, system unload automatically and give an alarm.

Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.

Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.

Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.

Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.

Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.

 

 

 

 

 

 

 

 

 

Hot Products

AC220V-500kW Dummy Load Bank With Frequency 60 HZ And Black , Grey Colour Introduction AC220V-500kW ...
AC440V-4375KVA Dummy Load Bank With Best Sales And High Performance Introduction Tailor-made load ...
AC430V-1500kvA Dummy Load Bank In Resistive Inductive And High Performance Introduction Triumph load ...
AC440V-500KVA Dummy Load Bank In High Performance And Resistive Inductive Introduction Tailor-made ...
AC415V - 271kVA Dummy Load Bank In High Performance And Resistive Inductive Introduction Triumph ...
AC480V-3546KVA Dummy Load Bank In High Performance And Resistive Inductive Introduction Triumph load ...