AC Variable Resistive 400v 1500kw Resistive Load Bank For Testing Generators UPS
 
Product Description

 

1. Load testing: load power that not beyond the rated power, testing and display stable state 3 phases voltage, current, active power, frequency, working time, etc of generator sets.

2. Load/unload with one key:Either by manual control or software control, user can preset the power, then press load master button. Load bank loaded according to preset power to avoid load fluctuation during the power changing.

3. Control Pattern: user can choose local control and intelligent control.

4. Local Control: There is local control panel with several power steps; user can load/unload by button.


Technical Parameters

 

Rating Voltage/Frequency400VAC 50Hz/60Hz,3phase 4 wire
Max Load PowerResistive Load: 1500kW
Load Step

Resistive Load:16 steps
1,2,2,5,10,10,20,50,100,100,200,200,200,200,200,200kW

Power Factor1
Load Tolerance(each step)±5%
Load Tolerance(overall)±3%
Display Precision0.5 class
Control Power SupplyExternal 415VAC, 3phase 4wire 50Hz
Wire Connection

Load Power Supply Input——Copper bar (star connection)
Control power supply input——Connector bar

Communication InterfaceRS232 and RS485
Insulation ClassF
Duty CycleContinuous
CoolingForced air cooling, horizontal air inlet and air outlet
TransportationHoisting, there are lifting lug in top of case and wheel castors on the bottom
Chassis colorGray(RAL7035)
Size

Approximately 1900mm*2900mm*2100mm
(Width *Length *Height)

WeightApproximately 2000kg
Ambient Temperature-10℃~+50℃
Relative Humidity≤95%
Altitude≤2500meters
Atmospheric Pressure86~106kPa

 
Product Advantage
 

Communication type: through RS232, RS485

Load mode: manual load or automatic load.

Manual load: input power and power factor.

Automatic load: User can set several periods of power and time, and in turn of 0%→25%→50%→75%→100%, etc preset order to make automatic load testing.


Application
 

UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment

Generators installed in the field must be periodically tested and exercised to ensure that it will operate as intended when a power outage actually occurs. Service groups use load banks to apply a load that mimics the load of the facility the generator is protecting. Any problems with the generator can then be identified and rectified in a non-critical environment.

 

 

Hot Products

ISO IEC CE Portable Electronic AC Load Bank Single Phase Durable With F Insulation Product ...
Portable Electronic 200kw AC Load Bank Single Phase Durable Testing Die Generators Product ...
High Load Power Density AC Load Bank 500kw Grade Orange Testing Generators UPS​ Product Description ...
Custome Design Power Density AC Load Bank Grade Orange With Phase Voltage​ Product Description The ...
AC Variable Resistive 400v 1500kw Resistive Load Bank For Testing Generators UPS Product Description ...
3 Phase AC Variable Resistive 400v 1500kw Resistive Load Bank With Copper Conductor Product ...