Home Companies Hebei Kaixiang Electrical Technology Co., Ltd

Small Volume Rack Mounted Load Bank Overheat Protection For Data Center

Hebei Kaixiang Electrical Technology Co., Ltd
Active Member

Contact Us

[China] country

Address: No33 Wangshan Road, Green Island Economic Development Zone, Shijiazhuang, China

Contact name:

Inquir Now

Hebei Kaixiang Electrical Technology Co., Ltd

Small Volume Rack Mounted Load Bank Overheat Protection For Data Center

Country/Region china
City & Province shijiazhuang hebei
Categories Uninterrupted Power Supply (UPS)
InquireNow

Product Details

AC220V-6kW Rack Mounted Load Bank With Frequency 50HZ And Best Sales

Introduction

This unit specially designed for data center, it’s safe, reliable, small volume and can simulate the on-site server load.

Constant power. This unit is self-developed electric power load simulation equipment.

The diagram in the agreement is only for reference, specific please in kind prevail.

Application

AC220V-6kW Rack Mounted Load Bank With Frequency 50HZ

When building a data center, any unexpected glitch during commissioning can cause serious project delays, wasted productivity, and significant budget overruns. So integrating rack mounted load banks into the design phase can help our data center clients keep projects on budget and on time.

Technical specification

 

System Parameter
Rating voltage/frequencySingle phase 220VAC/50Hz
Max Load PowerResisitive Power: 6kW
Load ResolutionResistive Load: 3 steps. A circuit 2kW; B circuit 2kW; C circuit 2kW;
Power Factor1
Load Tolerance+(0-10%)
Insulation GradeGrade F
Way of WorkingContinuous Working
CoolingForced air cooling, intake air in front and exhaust cooling in back
Case ColorBlack
Case DimensionAbout 440mm*440mm*222mm(L×W×H)
WeightAbout 18kgs
Working Environment Parameter
Ambient Temperature-10℃~+40℃
Relative Humidity≤95%
Altitude≤2500 meters
Atmospheric Pressure86~106kPa
Brands of Main Components
Gear SwitchABB
 

Main features
The load bank is with 2 gear switches, can load/unload through 2 gear air switches combination, Max power is 6kW. Please connect A loop switch at first when operating, and must keep the A switch in the open state. If overheat alarm, please turn off the power switch and then check the equipment problem.

(1) Load Test: User can load any power within rated power, and test the output capacity of under test power supply.

(2) Control Mode: The laod bank is with 2 gear switches, can control loading/unloading by 2 ABB air switches.

(3) Fan Power Supply: Fan is installed near the air outlet, and powered on A loop socket. Please give priority to the use A loop when using this load bank, the fan start after A loop is connected to power supply, then can load/unload through 2 gear air switches combination.

(4) Temperature Protection: There will be sound and light alarm when the load bank temperature exceeds the safety threshold value.

(5) Load bank Cable: The internal cable adopts multi core flame retardant flexible cord, and with glass fiber casing protection

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Products

Testing on Generator Sets 400V 500kVA Dummy Generator Load Bank Product Description 1. our load bank ...
Testing On Generator Sets 11kV 6000kW Dummy Generator Load Bank Product Description 1. This system, ...
Testing on Generator Sets 10.5V 2000kw Dummy Generator Load Bank Product Description According to ...
AC220V-4kW Rack Mounted Load Bank With Frequency 50HZ And Best Sales Introduction (1) This unit ...
AC220V-6kW Rack Mounted Load Bank With Frequency 50HZ And Best Sales Introduction This unit ...
AC120/240V-4kW Rack Mounted Load Bank With Frequency 60HZ And Best Sales Introduction AC120/240-4kW ...