VRL03 GFCI | Ground Fault Circuit Breaker

1. General

VRL03 Ground Fault Circuit Breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, rated current up to 50A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.

 

 

 

 

 

 

 

2. Technical parameters

2.1 The tripping characteristic curves are as shown below.

 

 

2.2 Basic parameters

 StandardIEC/EN 61009-1, AS/NZS 61009.1
Main SpecificationsModel No.VRL03
Rated current In6A, 10A, 16A, 20A, 25A, 32A, 40A, ,45, 50A
Classified by Type of Instantaneous TrippingType B: (3 ~ 5) In, Type C: (5 ~ 10) In
Poles1P + N
Type (wave form of the earth leakage sensed)Type AC, Type A
;Mechanical featuresRated voltage UeAC240V
Frame size rated current Inm50A
Rated residual operating current I△n0.01A, 0.03A, 0.1A, 0.3A
Rated residual non-operating current I△no0.005A, 0.015A, 0.05A, 0.15A
Rated short-circuit breaking capacity Icn230/240V 6000A, 10000A; 120V 15000A

Rated residual making and

breaking capacity I△m

500A
Electrical life2,000
Mechanical life2,000
Rated impulse withstand voltage Uimp6000V
ConnectionFrom top and bottom, from bottom and top

2.3 The residual current breaking times

In (A)I△n (A)Breaking time when the residual current assumes the following values (s)
I△n2I△n5I△n5A, 10A, 20A, 50A, 100A, 200A, 500A(a)I△t(b)
6~400.01, 0.03, 0.1, 0.30.10.050.040.040.04

a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.

2.4 The over-current protection characteristics

No.Rated current In (A)Initial stateTest current (A)Specified time (t)Expected resultRemarks
a6 ~ 40Cold state1.13 Int ≥ 1hNon-tripping 
bImmediately after sequence a1.45 Int < 1hTrippingIncrease to the specified current within 5s after test item a.
cCold state2.55 In1s < t < 60sTripping 
dCold state3 Int ≥ 0.1sNon-trippingType B
5 Int < 0.1sTripping
5 Int ≥ 0.1sNon-trippingType C
10 Int < 0.1sTripping

 

3. Outline

___________________________________________________________________________________________________________________

Product Description:

GFCI Circuit Breaker is a type A RCBO (Residual Current Circuit Breaker with Overload Protection) that is UL listed and designed to protect people from electric shock. It has a voltage rating of 120/240VAC and is equipped with a thermal magnetic trip type, an indicator light, and a plug-in mounting type. The GFCI Circuit Breaker is certified to provide ground fault circuit interrupter protection in a variety of residential and commercial settings.

The GFCI Circuit Breaker is designed to detect ground faults and shut off the power in an event of an electrical shock hazard. It is equipped with a thermal magnetic trip type which responds quickly to dangerous faults. The indicator light on the GFCI Circuit Breaker illuminates when a ground fault has been detected and the power is shut off. This helps to ensure that the circuit breaker is functioning properly and that the electrical system is safe.

The GFCI Circuit Breaker is designed for easy installation with its plug-in mounting type. It is UL listed and certified for use in a variety of residential and commercial settings. With its ground fault circuit interrupter protection, the GFCI Circuit Breaker is an essential safety device for any electrical system.

 

Features:

  • Product Name: GFCI Circuit Breaker
  • CSA Certified: Yes
  • Amperage Rating: 15A
  • Trip Type: Thermal Magnetic
  • Interrupt Rating: 10kA
  • Voltage Rating: 120/240VAC
  • RCBO TYPE B: Ground Fault Circuit Interrupter
  • RCBO TYPE A: Residual Current Breaker with Overload Protection
 

Applications:

HAROK GFCI Circuit Breakers: The Ultimate Protection for Your Home and Business

HAROK GFCI Circuit Breakers offer the ultimate protection against short circuits, overloads, and ground faults. The brand offers a range of RCBO Type A and Type B circuit breakers, including models VRL01, VRL02, VRL03, VRL11, VAL003, VKL003, VDL006, and VRL22. All HAROK circuit breakers are UL listed for your safety and feature a thermal magnetic trip type for superior protection. The circuit breakers feature a plug-in mounting type and push-in terminal type, and are available in 15-amp models.

Ground fault circuit interrupters (GFCIs) are one of the most important elements of a home or business electrical system, and HAROK GFCI Circuit Breakers provide reliable protection in a variety of applications. Whether you’re looking for protection in a residential home, commercial office, industrial site, or any other application, HAROK GFCI Circuit Breakers can provide the necessary protection.

HAROK GFCI Circuit Breakers provide superior protection from short circuits, overloads, and ground faults, protecting you and your property from the dangers of electrical fires. With their plug-in mounting type and push-in terminal type, they are easy to install and provide reliable protection for years to come.

 

Technical Parameters:

Product NameGFCI Circuit Breaker
Amperage Rating15A
NEMA RatingNEMA 1
Terminal TypePush-in
Interrupt Rating10kA
Mounting TypePlug-in
CSA CertifiedYes
Ground Fault ProtectionYes
Indicator LightYes
Number of Poles1 Pole
 

Customization:

GFCI Circuit Breaker

Brand Name: HAROK
Model Number: VRL01, VRL02, VRL03, VRL11, VAL003, VKL003, VDL006, VRL22
Place of Origin: CHINA
Terminal Type: Push-in
Product Name: GFCI Circuit Breaker
Trip Type: Thermal Magnetic
NEMA Rating: NEMA 1
Ground Fault Protection: Yes

HAROK GFCI Circuit Breakers are reliable and safe electrical components that provide ground fault circuit interrupter (GFCI) protection. They are equipped with NEMA 1 rating and come in various models such as VRL01, VRL02, VRL03, VRL11, VAL003, VKL003, VDL006, and VRL22. They are designed with push-in terminals and feature thermal magnetic tripping type for maximum safety and stability. These circuit breakers are perfect for residential and commercial applications and provide an added layer of protection against ground fault currents.

 

Packing and Shipping:

Packaging and Shipping for GFCI Circuit Breaker

The GFCI Circuit Breaker is packaged in corrugated cardboard boxes to ensure product protection during shipping. The box is labelled with the product name, model number, and other important information to help customers identify the product. The boxes are then placed in an outer cardboard box, which is sealed with tape to prevent tampering or accidental opening of the product box.

The products are shipped via a reliable courier service with an estimated delivery time of 2-4 business days. The customer is provided with tracking information to monitor the package's progress.

 

GFCI | Ground Fault Circuit Breaker

Hot Products

HRD7 GFCI | Ground Fault Circuit Breaker 1. General HRD7 Ground Fault Circuit Breakers are suitable ...
VKL003 GFCI | GROUND FAUL CIRCUIT INTERRUPTER 1. General VKL003 residual current operated circuit ...
VKL003 Residual Current Operated Circuit Breaker with over-current protection (MCB sized 1 module ...
VRL11 GFCI| Ground Fault Circuit Breaker 1. GeneralVRL11 residual current operated circuit breakers ...
VRL03 GFCI | Ground Fault Circuit Breaker 1. General VRL03 Ground Fault Circuit Breakers are ...
VRL02 GFCI | Ground Fault Circuit Interrupter 1. General VRL02 residual current operated circuit ...