FDA Venipuncture IgG IgM Rapid Coronavirus Test Kit

Country/Region china
City & Province tianjin tianjin
Categories Dyestuff Intermediates
InquireNow

Product Details

Novel Coronavirus (2019-nCoV) Antibody IgG/IgM Rapid Test Cassette

 

For the Qualitative Detection of IgG/IgM Antibodies in serum and plasma and Whole Blood

 

Main Features

 

1 Fast to get the result in 15-20 mins
2 High sensitivity and specificity
3 Simple to use
4 High Accurate (97.51%) and Reliable (Credibility interval: 95.79%~98.67%)
5 Ambient Storage
6 Certified by Authoritative Certification
7 Unique 3-line Patented Design
8

 Meet Multiple Criteria as follows:

 EN ISO 13485:2016 EN 13612:2002

 EN ISO 14971:2012 EN ISO 23640:2015

 EN ISO 18113-1:2011 EN ISO 18113-2:2011

 EN ISO 15223-1:2016 EN13641:2002

 

Principle

 

☀ This kit uses Colloidal Gold Immunochromatography and indirect immune capture principle of comprehensive detection technology to detect IgG/lgM of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in human serum, plasma and whole blood.

 

☀ During detection, the colloidal gold labeled recombinant antigens bind to the SARS-CoV-2 antibodies in the sample to form immune complexes. The immune complexes move forward along the cassette by chromatography.

 

☀ The IgM in the immune complexes will be captured by the pre-coated anti-human IgM on the test zone, condense the color to form the reaction line M. The IgG in the immune complexes will be captured by the pre-coated anti-human IgG on the test zone, condense the color to form the reaction line G.

 

☀ The colloidal gold-labeled chicken IgY antibodies are combined with the pre-coated goat anti-chicken IgY antibodies on the quality control line to form the quality control line C

 

 

Sample Collection and Test Preparation

 

Finger stick Specimens (Whole Blood)

 

☀ Clean the area to be lanced with an alcohol pad

 

☀ Squeeze the end of the fingertip and pierce it with a sterile lancet.

 

☀ Wipe away the first drop of blood with sterile gauze or cotton; collect the sample from the second drop

 

☀ Use dropper to draw the fresh blood to 1/ 2 of the tube wall and dispense into the sample well

 

Fingerstsick whole blood should be used immediately after can be used.

 

 

Serum/Plasma specimens: fresh serum or plasma specimen can be used.

 

Plasma

 

☀ Collect whole blood into a collection tube (containing EDTA, Na-citrate or heparin) by venipuncture

 

☀ Separate the plasma by centrifugation.

 

Serum

 

☀ Collect whole blood into a collection tube (containing no anticoagulants) by venipuncture.

 

☀ Allow the blood to clot.

 

☀ Separate the serum by centrifugation.

 

Avoid the use of hemolytic, turbid, microorganism contaminated specimens. Specimen should be stored at 2-8℃ for up to3 days or frozen at -20℃for up to 9 days. Avoid specimen deterioration by multiple freeze-thaw cycles

 

Venipuncture Whole Blood

 

Venipuncture whole blood can be used immediately after collection or stored up to 3 days at 2-8℃

 

Built-In Control

 

COVID-19 IgG/lgM Rapid Test Cassette has a built-in procedural control to see whether or not the operation is correct or effective, if one color line appeared on the control zone C, it indicates that the test operation is Correct.

 

Storage

 

COVID-19 IgG/IgM Rapid Test Cassette should be stored in dark place at 2-30°C for 12 months from the date of manufacture. Keep the test cassette in sealed pouch until use. Once you have taken the test cassette out of the pouch, use it immediately. Do not use the test beyond the indicated expiration date.

 

Warning

 

For in vitro diagnostic use ONLY

Read the package insert completely before use.It is very important that the correct procedure is followed. Fail to add the patient sample may lead to a false negative result (i.e.a missed positive) .

 

 

 

Hot Products

COVID-19 Novel Coronavirus(2019-NCoV) Nucleic Acid Detection Kit PCR-Fluorescence Probing Novel ...
Novel Coronavirus (2019-nCoV) Antibody IgG/IgM Rapid Test Cassette Main Features: Intended Use The ...
Novel Coronavirus (2019-nCoV) Antibody IgG/IgM Rapid Test Cassette For the Qualitative Detection of ...
Novel Coronavirus (2019-nCoV) Antibody IgG/IgM Rapid Test Cassette Home Use SARS-CoV-2 Antibody IgG...
Novel Coronavirus (2019-nCoV) Antibody IgG/IgM Rapid Test Cassette Home Use SARS-CoV-2 Antibody IgG...
Novel Coronavirus (2019-nCoV) Antibody IgG/IgM Rapid Test Cassette Coronavirus Antibody IgG/IgM ...