Home Companies Xi 'an West Control Internet Of Things Technology Co., Ltd.

Flanged 40m Radar Liquid Level Sensor IP67 24VDC 40BAR 0.05% FS

Xi 'an West Control Internet Of Things Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Block V5, Ronghao Industrial Town, Gaoling District, Xi'an City, Shaanxi Province

Contact name:Gao

Inquir Now

Xi 'an West Control Internet Of Things Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Flanged 40m Radar Liquid Level Sensor IP67 24VDC 40BAR 0.05% FS

Country/Region china
City & Province Shaanxi
InquireNow

Product Details

 

26GHz NYRD-PB-C Flat Radar Level Meter

 

The flat-panel radar level meter is a 26GHz high-frequency radar level measuring instrument with a maximum measurement distance of 40 meters. The antenna is further optimized, and the new fast microprocessor can perform higher-speed signal analysis and processing, so that the instrument can be used in some complex occasions such as steam, foam, dust, crystallization, condensation, etc..

 

Radar Level Meter Technical Parameter

 

ModelNYRD-PB-ANYRD-PB-BNYRD-PB-CNYRD-PB-DNYRD-PB-E
Typical applicationSteam, mist, foam, strong corrosion, crystallization, condensation, adhesion, etc.
Transmit frequency26GHz
Echo sampling100 times/s
Antenna materialPTFE+304PTFEPTFE+304PTFE+304PFA
Range40m
Accuracy0.05%~0.1%F.S
Supply power24VDC(Two-wire,Four-wire), 220V AC
Power3W
Signal output4...20mA/HART/RS485/Modbus...
Process temperature-40~+130℃-40~+130℃-40~+260℃-40~+130℃-40~+130℃
Process pressure-0.1~2.0MPa
Process connectionBracket, flange (optional)
Electrical InterfaceM20×1. 5, ½ " NPT
Protection classIP 67
Explosion-proof gradeExiaⅡCT6 Ga, ExdⅡCT6 Gb

 

 Note: Products can be customized according to the specific requirements of users!

 

Radar Level Meter Operating Principle

 

The radar level antenna emits narrow microwave pulses, which are transmitted downward through the antenna. After the pulse touches the surface of the measured medium, it is reflected back and received by the antenna system again, and the signal is transmitted to the electronic circuit part and automatically converted into a level signal (because the pulse propagation speed is extremely fast, the electromagnetic wave reaches the target and is reflected back to the receiver. The time taken is almost instantaneous).

 

Radar Level Meter Installation requirements

 

  • The radar level meter i s installed at 1 / 4 or 1 / 6 of the tank diameter. Note: The minimum distance f rom the tank wall should be 500 mm Figure 1 : ① Datum plane , ② Containercenteroraxisofsymmetry.
  • The to poftheconical tank is flat , which can be in stalledin the middle of the to pof the tank , which can ensure  the measurement to the bottom of the conical tank . As Figure 2
  • Gantrydoor installation method : The plastich or nantenna can al so be fixedly installed through the gantry door , As Figure 3

 

 

Radar Level Meter Wrong installation

 

  • The conical tank cannot be installed above the inlet  .Note: sunshade and rainproof measures should be taken when installing outdoors. Figure 4 : ① Right, ② Wrong
  • When there are obstacles in the tank that affect the measurement, a reflector must be installed to measure normally. Figure 5:① Right,② Wrong
 
 

Hot Products

26GHz NYRD-PB-C Flat Radar Level Meter The flat-panel radar level meter is a 26GHz high-frequency ...
NYRD803 Stainless Steel Housing Intelligent Radar Level Meter -40~250℃ Level Transmitter NYRD803 ...
NYRD803 Intelligent Radar Level Meter Radar level meter adopts microwave pulse measurement method, ...
26GHz NYRD-PB-D Flat Radar Level Meter The flat-panel radar level meter is a 26GHz high-frequency ...
NYRD803 (High Temperature Type)Intelligent Radar Level Meter Radar level meter is suitable for ...
NYRD701 ( Stainless Steel )1.8GHz Guided Wave Radar Level Meter Technical advantages of guided wave ...