Single Output AC220V Australia Socket PV Power Inverter
FAQ:
1.A Few Helpful Inverter Tips:
- Never leave an inverter connected to a line where other power (Vac)
may feed into inverter. It doesn’t matter if inverter is on or off.
Unless your inverter is a grid tie inverter.
- Using inverters in moist areas is a common cause for their drivers
to burn out. Even an outdoor extension cord that was lying in a
puddle a day previously may have enough moisture to burn out the
drivers of the inverter. Tip: if using inverter in rain one day,
allow cords that may have gotten wet to dry a few days before using
in inverter again
- Always prevent foreign objects from entering inverter through the
vent or fan openings
- Keep cables between inverter and batteries as short as possible.
This will help your batteries perform their best.
- Always use sealed batteries if you want to keep the inverter close
to the battery bank.
- Don’t over tighten nuts to battery or inverter, but do check them
occasionally to ensure they are snug.
- If the cables between your battery and inverter get hot while under
heavy load, then you should consider using heavier cables
- Both “hot” and “neutral” lines are hot on many inverters. Do not
ground the neutral line. Do not connect neutral to panels that may
have neutral grounded unless you are sure that the input and
outputs of inverter are isolated. Call the inverter manufacturer to
verify.
- Using a 12Vdc inverter, your input Voltage should never exceed
15Vdc (17Vdc for some models) or the inverter may shut down with
Over Temp and you should hear an audible beep. This may cause
permanent damage to an inverter
- When selecting an inverter, try to buy one that will stay in the
continuous operating range and do not rely on advertised surges.
This will help your inverter last longer and operate more
efficiently.
- Standard 110Vac outlets are typically rated at 1500W or 15Amps.
This is for heat dissipation through the outlet and is typically
not a limitation of the inverter
- If cables need to be run, it is best to keep inverter as close as
possible to your sealed deep cycle batteries. Use extension cords
on the output side (AC output) rather than extending the DC cables.
Tip: Contractors often need to mount the inverter in the back of
their trucks. In a case like this it would be best to mount a
secondary battery near the inverter and wire it to the primary
truck battery.
- An inline fuse is recommended in any inverter system, to protect
your batteries from a ground fault fire.
- Ac plug testers do not work with most inverters. You will see an
open ground
- Be aware of lightning storms. If struck, inverter could go to a
permanent Over load state and may even smoke.
- AC extension cords should not exceed 100 feet or you will have a
voltage drop and not push enough power down the line.
- Inverters emit RF and may cause interference. This is noticeable in
AM radio and often monitors and computer mice
- Never parallel multiple inverter outputs. This will generally burn
the ac drivers out.
- If the inverter does not turn on, or has a constant beeping sound,
verify you have the proper input voltage supplied to it. Also
ensure the battery connections are clean and secure.
- Never start a vehicle with inverter turned on, this will cause
eventual and permanent damage to inverters
- If you do run cables from battery to inverter that have any chance
of shorting to a chassis or ground, it is best to fuse the +
battery cable nearest to the battery as possible
Products Specification:
Model | SGPR600-121 | SGPR600-122 | SGPR600-241 | SGPR600-242 | SGPR600-481 | SGPR600-482 |
Rated Power | 600W |
Surge Power | 1200W(few seconds) |
Input Voltage | 12VDC | 24VDC | 48VDC |
Output Voltage | 110VAC±5% | 220VAC±5% | 110VAC±5% | 220VAC±5% | 110VAC±5% | 220VAC±5% |
USB Port | 5V 0.5A |
Frequency | 50Hz±3 or 60Hz±3 |
Output Waveform | Pure Sine Wave |
Soft Start | YES |
AC Regulation | THD<3%(Linear Load) |
Output Efficiency | 94% MAX |
No Load Current | 0.6A | 0.3A | 0.1A |
DC Voltage Range | 10-15.5V | 20-31V | 40-61V |
Low Voltage Alarm | 10.5±0.5V | 21±0.5V | 42±1V |
Low Voltage Shut Down | 10±0.5V | 20±0.5V | 40±1V |
Low Voltage Recovery | 13±0.5V | 24±0.5V | 48±1V |
Over Voltage Shut Down | 15.5±0.5V | 31±0.5V | 61±1V |
Over Voltage Recovery | 14.8V±0.5V | 29V±0.5V | 59V±1V |
Cooling Way | Intelligent Cooling Fan |
Protection | Battery Low Voltage & Over Voltage, Over Load, Over
Temperature, Short Circuit |
Working Temperature | -10ºC - +50ºC |
Net Dimension | 20.2*15*8cm (L×W×H) |
Meas./Ctn | 63*34*38.5cm / 10pcs |
N.W./Unit | 2.0KG |
G.W./Ctn | 24KGS |
Packing | box |
Warranty | 2 Years |
Inverter Display:
![](http://img.everychina.com/nimg/e6/46/b338a8e33aba44d0ad3bb78ac872.jpg)
![](http://img.everychina.com/nimg/81/81/e4f6937da5093cefe45eb1d2ba0d.jpg)