Home Companies Hefei Coolnet power Co., ltd

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

Hefei Coolnet power  Co., ltd

Contact Us

[China] country

Trade Verify

Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province

Contact name:Janet Si

Inquir Now

Hefei Coolnet power Co., ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

Country/Region china
City & Province hefei anhui
Categories Toilet Tissue
InquireNow

Product Details

Floor Standing Data Center PAC Server Room Precision Air Conditioner

 

Product Introduction                                 

Precision air conditioning units

1. Maintaining a constant temperature, purity and humidity of air is essential for ensuring a stable environment for critical electronic and computer equipment.

2. Unlike comfort air conditioning, close control systems must operate constantly 24/7 requiring high reliability and minimal power consumption.

3. Quiet, compact and energy efficient equipment that can be configured to needed requirements.

 

Benefits                                                    

 

Advantages                                          

 

1. High quality control component.

2. Efficient evaporator made from advanced technology and with larger heat exchange area.

3. Danfoss brand quality expansion valve.

4. Internationally advanced electrode steam humidification system.

5. Unique frame design guarantees the cabinet safety under any transport condition and operating environment.

6. G4 level air filter to guarantee the server room air purity.

7. Copeland hermetic scroll compressor.

8. Standard configuration with speed adjustable centrifugal fan. EC fan is optional.

9. Highly efficient PTC electrical heater.

10. Anti-corrosion alloy condenser.

 

Applications                                   

  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber

Technical Features                             

 

High reliability

Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition.

All-day running design can guarantee the main equipment safe operation.

All parts had passed severe test and confirmed stable and reliable before delivery.

 

High energy efficiency

Sensible heat ratio is up to 91%.

Compressor energy efficiency ratio is over 3.1, and chilled water

cooled unit’s cooling energy efficiency is larger than 25.

The optimal and high efficiency compressor and fans.

“W/M” type evaporator with super large heat exchange area.

Independent air duct design can reduce air resistance significantly and minimize fans power.

Variable frequency design on ODU is more efficient and has longer

working life.

Advanced control logic can effectively avoid competitive running

and output cooling capacity according to actual cooling capacity

demand.

 

Easy maintenance

Front panel maintenance: All maintenance work can be operated from front panel.

Air filter with metal frame: Cleanable repeatedly, low maintenance cost

Self-cleaning humidifier: lower maintenance work

Modular design with least spare parts

Pressure difference monitoring for air filters can detect whether

air filters was blocked or not.

 

Multiple types

Wide capacity range:

air cooled type(5kW~120kW),Water cooled type(5-120KW),chilled water cooled type(30kW~200kW).

Multiple cooling mode:

air cooled, water cooled, glycol cooled, chilled water cooled(with single/dual coil), air cooled & chilled water cooled, air cooled & free cooling, Freon pump free cooling.

Multiple air supplying modes:

cap tuyere mode, air duct mode, floorboard mode.

Multiple refrigerant types: R410A, R407C, R22.

Wide ambient air temperature rang:

standard range(-20℃~50℃),low temperature range(-40℃~50℃).

Technical Parameters                               

 

Model: CYAT26D/UT31D/UT35D/UT41D/UT45D/UT50D/UT55D/UT61D/UT70D/UT76D/UT85D/UT90D/UT100D/U
Power Supply380V 3Ph-50HZ
Air DischargeUpflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1)KW26.931.935.941.945.350.555.461.470.576.285.590.8102
SensibleKW24.829.533.138.842.547.851.657.565.271.279.584.595.7
AEERW/W3.63.63.63.63.63.73.73.63.63.63.63.63.6
Air Flowm3/h800095001000011500130001550016000175001850020500225002350024200
Compressor Hermetic scroll
RefrigerantR407C
Compressor quantityPC2222222222222
Fan Section Centrifugal fan (Optional EC)
Fan quantityPC2222222223333
Rated currentA4.34.34.34.44.44.455.25.26.516.516.516.5
Rated powerW1600160018001800200020003000330039003900540063006300
Total heating capacityKW66699999912121212
MaterialPTC
Humidifier Section Electrode type
CapacityKg/h5555131313131313131313
Rated CurrentA6666151515151515151515
Condenser Model 2*582*582*582*582*802*802*1002*1002*1202*1502*1502*1652*180

 

Certificates                                  

 

Factory Details                                         

 

Packing & Delivery                                       

 

Case                                               

 

 

 

 

 

 

 

 

Hot Products

8550m3/H Precision Air Conditioning Units Adaptable For Data Centers AC de precision del centro de ...
Floor Standing Data Center PAC Server Room Precision Air Conditioner Product Introduction Precision ...
Precision Air Conditioning Data Room Server Cabinet Rack Air Conditioning 380V 50Hz Precision Air ...
Emerson Precision Air Conditioning Applied In Computer Room And Data Center Product Introduction ...
50KW Precision Air Conditioning Units Dual Air Cooled System Product Introduction Cyber Master ...
380V 50Hz 100KW Precision Air Conditioners System For Modular Data Center Product Introduction ...