Home Companies Zhengzhou Great Electric Co.,Ltd.

0.05 Lab Electric Meter Test Equipment Set Output Independently

Zhengzhou Great Electric Co.,Ltd.
Active Member

Contact Us

[China] country

Address: No.1207-1, Building #1, the National University Sci-Tech Park of Henan Province, No.11 Changchun Road, Zhengzhou, Henan 450000

Contact name:Tony Han

Inquir Now

Zhengzhou Great Electric Co.,Ltd.

0.05 Lab Electric Meter Test Equipment Set Output Independently

Country/Region china
City & Province zhengzhou henan
Categories Other Electric Power Tools
InquireNow

Product Details

Single & Three Phase Meter Test Bench MCTB16B

 

Technical Parameters

Accuracy class0.05, 0.1 (optional)
Output Voltage
Range3*(1-450V) (P-N)
Resolution0.01%
THD<0.5%
Accuracy & Stability0.05% or 0.02%
Capacity≥ 800VA/phase (20 positions)
Current output
Range3* (1mA~ 120A), maximum can be 200A
Resolution0.01%
Distortion<0.5%
Accuracy & Stability0.05% or 0.02%
Capacity≥ 2500VA/phase (20 positions)
Phase angle
Adjustment range0° ~ 360°
Resolution0.01°
Frequency
Range45-65HZ
Resolution0.01HZ
Other parameters
Different value of each phase voltage and average value<0.5%
Different value of each phase current and average value<1%
Time base1 ~ 9999s
Insulation between Voltage circuit vs. Current circuit, Between circuits vs. Earth≥ 5MΩ
Power supply220V or 3×240V/415V±10%, 50/60Hz±10%
Ambient conditions50C ~ 400C / up to 90% RH

 

 

Features

1) PWM (Pulse width modulation) technology

2) Modular design allows customized configurations on hardware and software, customer-friendly

3) Perform all basic tests like warm up, creep test, start test, basic errors, standard deviation and etc.

4) Perform dial test with pulse counting & timing base with KWH value

5) Mode of tests: Fully-automatic, or manual operation by manual control touch screen (MCU)

6) Able to test all types of single phase and three phase mechanical meters, electronics meters, CT/PT

    operated meter, smart meter, closed-link meter, and etc..

7) Error calculation display with reset buttons on each meter position

8) Flexible Quick connector device (QCD) for convenient changeover from three phase meter

    to single phase meter

9) Black mark search & capture for rotation disk

10) Able to calibrate mechanical or electronics meters with different constant at the same time

11) Test Records save in database with MDB format or other required format

12) Calibrate parameters including voltage, current of each phase, phase/phase difference,

      active/reactive/apparent power of each phase, total active/reactive/apparent power, total power factor,

      frequency, etc. with real time display of vector graph

13) Harmonic test 2-21times and analysis/display of harmonic

14) With facilities to test apparent maximum demand recorded in meters and carry out the register test

      (the client should provide meter communication protocol for this function)

15) Self-testing function for all phases power, total power stability, symmetry of 3 phase voltage and current

16) PC software (communication by RS232) can realize MIS net interface connection function, can easily

      upgrade in the future if necessary

17) Protection: current open-circuit, voltage short-circuit and malfunctions, Auto protection & auto restore

18) Start & Stop button on power source

19) Alarm lights installed on top of power source

20) Can be independent set & output of each phase voltage & current, phase angle

 

MTB Comprising:

1) Three Phase Reference Standard Meter

2) Three Phase Power Source

3) Meter Mounting Racks

4) MCU (manual control unit, touch screen operation)

5) Scanning Heads

6) Error Processing & Calculation & Indication System

7) PC software, PC, printer, etc..

 

Technical Specifications

 

Three Phase Power Source

Voltage Source

Output Ranges: 3 x (0-380V) P-N

Resolution: 0.01%

Distortion: ≤ 0.5%

Output Stability: ≤0.05% /3minutes

Output power: more than 800VA per phase

Setting accuracy of amplitude: 0.05%

Current source:

Output range: 3 x (1mA ~ 120A)

Resolution: 0.01%

Distortion: ≤ 0.5%

Output Stability: 0.05%/3minutes

Capacity: more than 2800VA per phase

Setting accuracy of amplitude: 0.05%

Output Phase angle:

Adjustment range: 0° ~ 360°

Resolution: 0.01°

Setting accuracy: 0.05°

Output frequency

Adjustment range: 45Hz ~ 65Hz

Resolution: 0.01Hz

 

 

 

Other Features

 

1) Time base: 1 ~ 9999s

2) Insulation between Voltage circuit vs. Current circuit, Between circuits vs. Earth: ≥ 5MΩ

3) Power supply: 240V or 3×240V/415V±10%, 50/60Hz±10%

4) Ambient conditions: Temperature 50C ~ 400C

5) Relative humidity: up to 90%

 

 

Meter Rack Configurations

Three Phase Test Racks (16 positions, one rack, two row)

Three Phase Test Rack

Number of positions: 20 (6, 8,10, 12, 16, 32, 40 also available for option)

Two emergency stop switch

Each position consist of: 1 QCD 6 pins + 1 scanning head + 1 meter mounting

+ 1 RS/232/485+1 optical probe (DLMS meter reading)+ communication port + 1 error display (4.5 digits)

+1 BNC pulse port + 1 RESET button + 1 Set of voltage cables+1 ICT

Provision for calibrating standard meter against higher level standard

One serial server

Isolated Current Transformer (ICT) specification:

Accuracy class: 0.01% (0.5C-1-0.5L)

Current Ratio: 1:1 (1mA-120A)

Current output: 3*(0.001-120)A (both primary and secondary)

 

Hot Products

Three Phase Meter Test Bench SYD32-6A 1) PWM (Pulse width modulation) technology, 85% efficient 2) ...
Three Phase Aging and Cyclometer Test Equipment Positions: 48Nos, or more for options Feature & ...
Single & Three Phase Meter Test Bench MCTB16B Technical Parameters Accuracy class 0.05, 0.1 ...
Single Phase Energy Meter Withstand Voltage Test Bench Feature & Function 1. With special programmab...
Single Phase Meter Aging and Cyclometer Test Equipment 1. Widely used in meter factories 2. Stable ...