CT PT TEST Equipment System HES-30

 

Technical Parameter

 

HES-30 CT/PT Test Bench

 

Input Voltage:AC 220V±10%, 50Hz, Single-Phase
Input Current:AC 0-120A
Rated Capacity:30kVA
Output Voltage:AC 0-250V
Output Current:AC 0-120A

 

 

HES-1Bx Transformer Tester

Measure item:Ratio errors & Phase errors of the CT and PT
Rated current:5A, 1A
Rated voltage:100V, 110V, 115V, 120V, 150V, 200V, 220V, 230V
Multiplier:1/√3, 1/3, 1, 1.5, 2
Accuracy class:±2%
Operation range:(1%-120%).In, (20%-120%).Un
Frequency:50Hz or 60Hz
Ratio error range:±0.0001% ~ ±19.99% (3 ranges: 0.1999%, 1.999%, 19.99%).
Minimum resolution:0.0001%.
Phase error range:0.01' ~ ±900' (3 ranges: 9.00', 90.0', 900')
Minimum resolution: 0.01'
Impedance range:0.001Ω~ 19.99Ω.
Minimum resolution: 0.001Ω.
Admittance range:0.001 ms ~ 19.99 ms.
Minimum resolution:0.001 ms.
Alarm Function:Provided the sound & light alarm function when the polarity abnormal or ratio inconsistent.

 

Input Load:

- On Standard CT secondary side: ≈0.11Ω, COSφ≈1.0

- On Test Object CT secondary side: ≈0.003Ω, COSφ≈1.0

- On Standard PT secondary side: ≈0.05VA (100V)

Communication Interface:Provided the RS232 serial PC communication interface
Display model:LCD
Power supply:AC 220V±10%, 60Hz
Power consumption:< 20VA
Product Type:Portable type.

 

 

CT Burden FY47-49

Rated Current:5A, 1A

 

Power Factor

and Rated Burden:

In=5A:

COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA

COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA

(more option available)

In=1A:

COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA

COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA

(more option available)

Accuracy Class:±3%
Operation Range:(1%-120%). In
Frequency:50Hz or 60Hz
Withstand Voltage:2kV/1min
Insulation:Air
Operating Model:Short-time (Used in CT Accuracy Testing System)
Product Type:Portable type.

 

High-current Test Cables of the CT

Cables includes: 3000A(600mm2) x 3m x 2pcs, 1000A(200mm2) x 5m x 1pc

500A(100mm2) x 3m x 2pcs, 250A(50mm2) x 3m x 2pcs

 

 

HLB-50G1 Standard CT

 

 

Rated Primary Current(A):

5, 7.5, 10, 12.5, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 125, 150, 160, 200, 250, 300, 315, 350, 400, 450, 500, 600, 630, 700, 750, 800, 900, 1000, 1200, 1250, 1400, 1500, 1600, 1800, 2000, 2500, 3000, 3150, 3500, 4000, 4500, 5000A

(more option available)

Rated Secondary Current:5A, 1A
Rated Current Ratio:5A~5000A/5A, 5A~5000A/1A (more option available)
Accuracy Class:0.01S% (0.05%, 0.02%, 0.01% or better are available)
Rated Secondary Burden:0.2Ω (Burden is 5VA at I2 = 5A, Burden is 0.2VA at I2 = 1A)
Power Factor:COSΦ=1.0
Operating Range:(1%-120%). In

 

Connection Mode:

Fixed connection terminals at Pri.current range is 5A-450A

Pass-through connection with 2 turns at Pri.current range is 500A-900A

Pass-through connection with 1 turn at Pri.current range is 1000A-5000A

Frequency:50Hz or 60Hz
Voltage Level:AC 600V
Withstand Voltage:2000V 1min
Insulating Medium:Air

 

 

SLQ-30KVA Current Generator

 

Input Voltage:AC 0-250V
Output Current:AC 0-5000A
Rated Capacity:30kVA
Rated Input Current:AC 120A
Frequency:50Hz or 60Hz
Current Output Model:

Fixed terminal at current is 50A, 200A, 500A

Through-hole connection at current is 500A-5000A

Products Shape:Stainless Steel Box
Working condition:0 - 40ºC, RH ≤ 90%

 

 

FY95-1 PT Burden

Rated Voltage:100V, 100/√3V, 100/3V
Power Factor:COSФ=0.8, COSФ=1.0
Rated Burden (VA):

1.25VA, 2.5VA, 5VA, 10VA, 20VA, 40VA, 50VA, 80VA, 100VA

(more option available)

Total Output Burden:308.75VA (more option available)
Accuracy Class:±3%
Operation Range:(20%-120%). Un
Frequency:50Hz or 60Hz
Withstand Voltage:2kV/1min
Insulation:Air
Operating Model:Short-time (Used in PT Accuracy Testing System)

 

 

 

 

HJB-220G3 Standard PT

Rated Primary Voltage:110/√3kV, 220/√3kV
Rated Secondary Voltage:110V, 110/√3V, 100V, 100/√3V

 

Rated Voltage Ratio:

110/√3/0.11/√3kV, 110/√3/0.11kV, 110/√3/0.1/√3kV, 110/√3/0.1kV

220/√3/0.11/√3kV, 220/√3/0.11kV, 220/√3/0.1/√3kV, 220/√3/0.1kV

Accuracy Class:0.05% (100/√3V,110/√3V), 0.1% (100V,110V)
Rated Secondary Burden:0.2VA(110V, 100V), 0.07VA(110/√3V, 100/√3V)
Power Factor:COSΦ=1.0
Operating Range:(20%-120%). Un
Frequency:50Hz /60Hz
Insulation:SF6 Gas

 

 

 

 

 

 

 

 

 

 

 

 

 


HJC-80 Resonant High Voltage Source

 

 

Product Application:

The system is a voltage generator, and used for Capacitive PT accuracy testing with 110/√3kV and 220/√3kV voltage level
Rated input voltage:AC 220V
Rated output voltage:AC 0~200 kV
Rated Capacity:200 kVar
Max output current:AC 1.0 A
Frequency:50Hz or 60Hz
The capacitance of the object CVT:0.004uF ~0.02uF
Operating Condition:Temperature: -10oC ~ +50 oC
RH: up to 85% (max. 90%, non-condensing)

 

LCB-10KVA/10KV Exciting Transformer

Input Voltage:AC 0 - 250V, 50Hz
Output Voltage:AC 0 - 10kV, 50Hz
Output Current:AC 0-1A
Rated Capacity:10kVA
Insulation:Dry type
Weight:~ 50 kg

 

DKQ-40KVA/40KV Reactor

Rated Capacity:40kVA/stage
Rated Voltage:AC 40 kV/stage
Rated Current:AC 1 A/stage
Inductance Range:125H-500H/stage
Insulation:Epoxy resin casting
Weight:~ 60 kg/stage
Quantity:5pcs

 

 

 

 

Hot Products

CT PT Analyzer Test Equipment MCVT-01C Major Technical Parameters Item Description Power Supply ...
Porable CT PT Test Equipment Analyzer MCVT405 Main Features CT Test PT Test 1) Excitation curve and ...
Induction Voltage Divider HJF3 1. Usage HJF3 type induction voltage divider is used for testing and ...
0.02S Standard Current Transformer CT PT Test Equipment Test System Measure Item Test Range CT ...
CT PT TEST Equipment System HES-30 Technical Parameter HES-30 CT/PT Test Bench Input Voltage: AC ...
CT PT TEST Equipment System HES-30 Configuration Standard CT, ±0.01S% Standard PT (6kV-38.5kV), ±0...