Surge protector lightning protector is used to protect
sensitive lines from lightning induction voltage, power grid
voltage fluctuation, electrostatic discharge and surge voltage
caused by large load start-up. It is widely used in family housing,
third industry and industrial field.
Structure and Principle
SPD is a port, shocking protection, indoor-mounted installation, voltage-limited.
SPD hold disconnector inside, when SPD breakdown failure by over heating, the disconnector can remove from the power grid automatically, and show indication signal. When SPD is working properly, visible window display green, it display red when it breakdown and disconnect.
1P+N,2P+N,3P+N SPD consist of 1P,2P,3P SPD+NPE zero ground protection module, apply to TN-S, TN-C-S and other power supply system.
Product specification
Model | TRS4-D10 | TRS4-D20 | TRS4-C40 | TRS4-B60 | |
Rated Operating Voitage | UC | 440 | 440 | 440 | 440 |
Voltage protective level | Up(KV)≤ | 1.5 | 1.8 | 2.1 | 2.3 |
Max discharge current | Imax(8/20μS) | 10 | 20 | 40 | 60 |
Nominal discharge current
| In(8/20μS) | 5 | 10 | 20 | 30 |
Ressponse time | NS | <25 | |||
Lndication of invalidation | Aging invalidation:green Normal,red:Invaldation | ||||
Operating condition | Temp:-40℃~+70℃ | ||||
RH≤95%(25℃) | |||||
Sea level elevation≤3km | |||||
Remote signal function
| Can also picking | ||||
Remarks | Other max continuous operating voltage can be customized |
Product features
1. safety insulation of fire retardant and high flame
retardant material
2. self protection voltage is more than self
protection, automatic disconnection and recovery.
3. limit the precision of the voltage to say how much!
4. detachable assembly and pluggable convenience
Notice of product
1. generally speaking, it is better to separate the
protected conductor from the non protected conductor, and it should
be separated from the ground wire. At the same time, in order to
avoid transient orthogonal coupling between power cables and
communication cables, necessary measurements should be made.
2. identify the input / output interface identifier of
the lightning protector, input the external line and output the
connection device.
3. connect the grounding wire of the lightning
protector with the ground wire of the lightning protection system.
4. after correct installation, it can work steadily for a
long time. If it is found that the transmission performance of the
system is reduced or the signal is interrupted due to the cause of
surge protection, it should be maintained or replaced in time.
Working principle of product
The function of surge protector is to limit the
transient overvoltage to the power line, the signal transmission
line in the voltage range that the equipment or system can bear, or
to inflow the powerful lightning discharge into the ground, and
protect the protected equipment or system from damage by the
impact.
Company profile
Thor has been designing new products to meet the RoHS
directive since 2006. Thor’s ongoing commitment to RoHS compliance
includes continuing efforts to reduce the presence of hazardous
substances in the design and manufacture of a growing number of
popular products.