Zhejiang THOR Electric Co., Ltd |
|
RS485 control signal, lightning protector, 4-20MA analog signal, lightning protector 5V/12V/24V.
Brief introduction
The control signal lightning arrester is a lightning
protection measure developed by Zhejiang tohr Electric Co., Ltd.,
which is independently developed for signal circuit protection. The
lightning protection for the control signal and the twisted pair
data line can prevent the induced overvoltage current from the
thunder or the industrial noise and the other instantaneous surge
voltage to cause damage or instantaneous interruption of all kinds
of dial-up equipment or systems.
Product features
1. energy saving, environmental protection, easy installation,
suitable for all kinds of standard interface types.
2. the coefficient of standing wave is small and the range
of working frequency is wide
3. when lightning strikes, there will be no need to
stop the electrical equipment when it enters the electric surge,
and it will not affect the operation of the normal equipment.
Product specification
Model and specofocation | TRSS-BNC | ||||||
Working voltage | 24V | ||||||
Max continuous operating voltage | Uc | 30V | |||||
Voltage protective level | Up(V)〈 | 〈60 | |||||
Nominal discharge current | In(8/20μS) | 10kA | |||||
Response time | ns | ≤10 | |||||
Characteristic impedance | 75Ω | ||||||
Insertion loss | ≤0.1dB | ||||||
Configuration dimension | 52×25×25 | ||||||
Interface mode | BNC | ||||||
Operating condition | Temp:-40℃~+70℃ | ||||||
RH≤95%(25℃) | |||||||
Sea level elevation≤3km | |||||||
Remarks | Other max continuous operating voltage can be customized |
Working principle of product
The control signal surge protector is connected to the
front end of the protected equipment. When the transmission line is
impacted by the inductive thunder and other transient overvoltage,
the impact current is discharged to the earth through the
protection branch of the surge protector, and the output voltage is
placed in the allowable voltage range of the equipment, thus
ensuring the safety of the operating equipment.
Use of attention
1. lightning arrester should be connected to the shortest possible
line. The protector grounding adopts terminal grounding mode, and
the grounding wire must be connected to the lightning protection
ground wire (or the enclosure of the protected equipment). The
shielding wire of signal can be directly connected to the grounding
terminal.
2. please recognize the interface and the way of connection
3. grounding lines should be short, thick and straight,
so as to reduce the influence of distributed inductors on the
ability of lightning electromagnetic pulse.
Product packaging:Carton packing
Transportation method
2. Trains, ships, aircraft transport