Home Companies Ningbo Brando Hardware Co., Ltd

CA45DD 1-1/2'' Inch Dresser Nut Integral Pilot Dust Collector Valve

Ningbo Brando Hardware Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China

Contact name:Brandon Bao

Inquir Now

Ningbo Brando Hardware Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

CA45DD 1-1/2'' Inch Dresser Nut Integral Pilot Dust Collector Valve

Country/Region china
City & Province ningbo zhejiang
Categories Valves
InquireNow

Product Details

CA45DD 1-1/2'' Inch Dresser Nut Integral Pilot Dust Collector Valve

 

Pulse Jet Valve play an important role in dust collector. A dust collector is a system used to enhance the quality of air released from industrial and commercial processes by collecting dust and other impurities from air or gas. Designed to handle high-volume dust loads, a dust collector system consists of a blower, dust filter, a filter-cleaning system, and a dust receptacle or dust removal system. It is distinguished from air purifiers, which use disposable filters to remove dust.

 

The diaphragm divides the electromagnetic pulse valve into two front and rear air chambers. When the compressed air enters the rear air chamber through the orifice, the pressure of the rear air chamber will press the diaphragm close to the output port of the valve, and the electromagnetic pulse valve is in " Disabled. The electrical signal of the pulse injection controller disappears, the solenoid pulse valve armature is reset, the air release hole of the rear air chamber is closed, the pressure of the rear air chamber rises to make the diaphragm close to the valve outlet, and the electromagnetic pulse valve is in the "closed" state.

 

Maintenance Kits:

ModelNitrileFKMLow Temperature–60°C (–76°F) MIN.Includes
CA/RCA25DDK4502K4503K4522Diaphragm kits include main and secondary diaphragms and all spring
K4510K4511NA2 dresser seals, 2 dresser nuts, 2 seal retainers
K0380K0384NAo-ring, armature assembly, armature spring, ferrule

 

Technical Data of Goyen Pulse Jet Valve:

Model
CA20DD
CA25DD
CA45DD
Nominal Size
20
25
45
Port size
mm
20
25
40
in
3/4
1
1 1/2
Number of Diaphragms
1
1
2
Flow
Kv
12
20
44
Cv
14
23
51
Pressure (Psi)
5 to 125
5 to 125
5 to 125
Temperature℃
NBR
-40 to 82
-40 to 82
-40 to 82
FKM
-29 to 232
-29 to 232
-29 to 232


Main Dimension:

 

CA RCA Series Pulse Jet Valve For Dust Collector System:

 

Thread Valve
1/2''
3/4''
1''
1.5''
1.5''
2''
2.5''
3''
CA15T
CA20T
CA25T
CA35T
(Single Diaphragm)
CA45T
(Double Diaphragm)
CA50T
CA62T
CA76T
Dresser Nut Valve
1''
1.5''
CA25DD
CA45DD
Flanged Valve
1.5'' Inlet
2'' Inlet
CA25FS
CA45FS
Immersion Valve
φ60 Outlet
φ75 Outlet
φ89 Outlet
φ86 Outlet
CA50MM
CA62MM
CA89MM
Remote Pilot Valve
1/8''
1''
1.5''
2''
RCA3D2
RCA25DD
RCA45T
RCA50T

 

Main Part of CA45DD Pulse Valve:

Solenoid Coil

Solenoid is the generic term for a coil of wire used as an electromagnet. It also refers to any device that converts electrical energy to mechanical energy using a solenoid. The device creates a magnetic field from electric current and uses the magnetic field to create linear motion. Common applications of solenoids are to power a switch, like the starter in an automobile, or a valve, such as in a sprinkler system.

Armature

An armature assembly for a solenoid valve allows for a valve member to be retained in the closed position through a biasing force being applied therein. A moveably supported armature bolt is movable between a first position and a second position. A valve member is coupled to the armature bolt and is configured to close with the armature bolt at the second position. An armature body is coupled to the armature bolt. A resilient member adapted to hold the armature bolt at the second position so as to retain the valve member in the closed position.

Diaphragm

The purpose of a diaphragm in a diaphragm type solenoid valve is to control the air within a certain space. These control valves can also be either open or closed, depending on the movement of the magnetic core.

Main Body

1.Different body material can be used in different working environment.
2.Different Connection Type can be used in different place, suitable for different installation way.

Focus on your demands, Offer you best solution:

 

√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing

 

Welcome to your any question and inquiry!

Hot Products

Water Solenoid Valve Coil 12VDC 24VDC 24VAC 110VAC 220VAC 22VA 18W This solenoid coil is popularly ...
CA76T 3'' Inch Right Angle Diaphragm Baghouse Pulse Jet Valve This is CA76T Goyen Type Right Angle ...
RCA25DD 1" Inch Quick Mount Dust Collector Remote Pilot Valve CA & RCA Series Pulse Jet Valves: 1. ...
CA25DD 1'' Inch Dresser Nut Diaphragm Pulse Jet Valve This is CA25DD Goyen Type Dresser Nut Pulse ...
CA45DD 1-1/2'' Inch Dresser Nut Integral Pilot Dust Collector Valve Pulse Jet Valve play an ...
4HV210-06 Airtac Type Manual Hand Lever Air Valve 4/2 Way The Airtac type 4HV series are reliable ...