8mm Hole DIN 43650B 4V100 Series Pneumatic Solenoid Valve Coil

Country/Region china
City & Province ningbo zhejiang
Categories Valves
InquireNow

Product Details

8mm Hole DIN 43650B 4V100 Series Pneumatic Solenoid Valve Coil

 

Applicable Industries:Solenoid Valve
Type:Fittings
Place of Origin:Zhejiang, China
Brand Name:Brando
Hole Size:8.0mm
Height:23.5mm
Width:17.0mm
Voltage:AC220V, DC24V
Power:5VA, 2.8W
Connection Type:DIN43650C
Insulation class:F, H
Protection class:IP65, IP67, IP68
Application:4V110 pneumatic valve

 

Dimension of 4V110 series pneumatic valve Solenoid Coil :

Dimension of 4V110 series pneumatic valve Solenoid Coil :

Technical Data:
 

Model
BB08023514
Hole size
8.0mm
Height
23.5mm
Width
17.0mm
Voltages
AC220V, DC24V
Power
5VA, 2.8W
Insulation class
F, H
Connection Type
DIN43650C
Application examples
4V110 series pneumatic valve

 

Attention:

1. This air suspension compressor pump solenoid coil is made of high quality components.
2. Replaces the original air compressor solenoid coil of your car and equal the original quality.
3. Please double confirm the compatibility as well as the OEM number before purchasing.
4. Instruction is not included. Professional installation is recommended.

 

 

Why do solenoid coils burn out?


Solenoid coils are designed to convert electrical energy into mechanical movement by means of a magnet field, which means as they consume power like a light bulb for example they will become hot, and the higher the wattage or power consumption or the longer they are switched ON the hotter they can become.

If the coil becomes too hot or above its temperature rating (copper winding class rating) the copper or insulating material can fail to short circuit.

Other reasons include high media or ambient temperatures preventing the coil from cooling sufficiently, water ingress between armature and coil or if the coil is removed whilst energised!!

 

Steps and methods for properly installing a solenoid valve coil:

1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.

2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.

3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.

4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.

5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.

6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.

7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.

 

Focus on your demands, Offer you best solution:

 

√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing

 

Welcome to your any question and inquiry!

Hot Products

DMF-Z-40S 1-1/2'' Inch Right Angle Type Dust Collector Pulse Jet Valve DMF-Z-40S diaphragm pulse ...
DMF-Z-62S 2-1/2'' Inch Right Angle Dust Collector Diaphragm Valve DMF Series BFEC Pulse Jet Valve: 1...
DMF-ZM-25 1'' Inch Dust Collector Quick Mount Pulse Jet Valve The diaphragm valves suitable for dust ...
DMF-ZM-40S 1-1/2'' Inch Compression Fitting Double Diaphragm Valve Tips on repairs: 1.Before ...
8mm Hole DIN 43650B 4V100 Series Pneumatic Solenoid Valve Coil Applicable Industries:Solenoid Valve ...
Pneumatic Valve DIN 43650 B EVI 7/8 Magnetic Solenoid Coil Applicable Industries:Solenoid Valve Type...