Home Companies Ningbo Brando Hardware Co., Ltd

ASCO Type 400325 Series Pulse Jet Valve Replacement Magnetic Coil

Ningbo Brando Hardware Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China

Contact name:Brandon Bao

Inquir Now

Ningbo Brando Hardware Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

ASCO Type 400325 Series Pulse Jet Valve Replacement Magnetic Coil

Country/Region china
City & Province ningbo zhejiang
Categories Valves
InquireNow

Product Details

ASCO Type 400325 Series Pulse Jet Valve Replacement Magnetic Coil

 

These external circuits can be as simple as connecting the coil in series with a parallel connection of a resistor and a capacitor. In such a circuit, charging the capacitor through the coil provides an initial coil current spike. After the capacitor is charged, the current-limiting resistor passes all the current. The downside of such a simplistic approach is that some of the power is wasted on heating the current-limiting resistor.

There are much more complex approaches involving switched power supplies which provide a programmable current to the coil. These power supplies may work with both AC and DC solenoid valves and power supplies. They ensure a good valve opening spike and reduced power consumption while the valve is open, resulting in better power efficiency, less heating and prolonged solenoid valve service life.

 

 

The 400325642 400325101 400325118 ASCO Type solenoid coil is applied to ASCO SCG353A043, SCG353053 Pulse Valves, and the air inlet of the ASCO type pulse solenoid valve is connected to the clean air with a pressure of 0.8 MPa for 60 minutes, and the leakage condition of each sealing portion on the electromagnetic pulse valve is checked. The pulse valve is The compressed air switch of the pulse bag type dust collector cleaning system is controlled by the pulse blowing controller, and the filter bag is sprayed and cleaned step by row, so that the resistance of the dust collector is kept within the set range. In order to ensure the dust collector's processing capacity and dust collection efficiency is good.

 

Technical parameters of ASCO Type 400325642 400325101 400325118 Solenoid Valve Coil:

Model numberBB11036001
Ref number400325642, 400325101, 400325118
Normal voltageAC110V, AC220V, DC12V, DC24V (Other can be customized)
Normal powerAC:20VA, DC: 21Watt
MaterialBMC, Brass
Wire classH
ConnectionDIN43650A
ApplicationASCO SCG353A043, SCG353053 Pulse Valve
Hole diameter11 mm
Height36 mm
Width38.5 mm

 

ASCO type SCG series pulse valve repair kits and coils comparison table:

Valve ModelRepair KitsSolenoid Coils
ACDC24VDC24 VAC110VAC220VAC
SCG353A043C113444C113444400325642400325101400325118400325118
ACG353AD44C113444C113444400325642400325101400325118400325118
ACG353052C113444C113444400325642400325101400325118400325118
SCG353053C113444C113444400325642400325101400325118400325118
SCG353AD47C113827C113827400425342400425101400425118400425117
SCG353050C113685C113686400425342400425101400425118400425117
SCG353051C113685C113686400425342400425101400425118400425117
SCG353060C123432C123433400425342400425101400425118400425117
SCG353AD65C113827C113827400425342400425101400425118400425117

 

Main dimension of 400325642 400325101 400325118 ASCO Type  Pulse Valve Coil:

 

Details enlargement of Pulse Valve Solenoid Coil ASCO Type 400325642 400325101 400325118:

 

Production display of ASCO Type 400325642 400325101 400325118 Solenoid Coil:

 

 

More details about 400325642 400325101 400325118 Solenoid Coil For ASCO SCG353A043 SCG353053 Pulse Valve in below Youtube Video:


 

The common problem that the solenoid valve does not take action. It should be checked from the following aspects:


1. The solenoid valve terminal is loose or the wire head is falling, the solenoid valve is not electric, and the wire end can be tightened.


2. The solenoid valve coil is burnt out. The wiring of the solenoid valve can be removed and measured with a multimeter. If the circuit is open, the solenoid valve coil is burned out. The reason is that the coil is damp, causing poor insulation and magnetic leakage, and the current in the coil is too large to burn, so it is necessary to prevent rainwater from entering the solenoid valve. In addition, the spring is too hard, the reaction force is too large, the number of turns of the coil is too small, and the suction force is insufficient to cause the coil to burn. For emergency handling, the manual button on the coil can be turned from the "0" position to the "1" position during normal operation, causing the valve to open.


3. The solenoid valve is stuck: the clearance between the sliding valve sleeve and the valve core of the solenoid valve is very small (less than 0.008 mm), and it is usually a single piece disassembly. When no mechanical impurities are brought in or the smooth oil is too small, it is easy to get stuck. . The disposal method can be made by rubbing the wire from the small hole in the head to make it bounce back. The basic treatment method is to remove the solenoid valve, take out the valve core and the valve core sleeve, and clean it with CCI4, so that the valve core is sensitive in the valve sleeve. When assembling, pay attention to the disassembly sequence and internal wiring status of each component, so as to re-disassemble and wire correctly, and also to check whether the oil mist injection hole can be infiltrated, and whether the smooth oil is sufficient.


4. Leakage: Leakage will result in a lack of air pressure, making it difficult to open and close the forced valve. The reason is that the gasket is damaged or the spool is worn to form several cavity helium. When dealing with the problem of switching the fragmented solenoid valve, an appropriate opportunity should be chosen. When the solenoid valve is in the event of power loss, the treatment should be stopped. If the treatment is not completed within a switching gap, the switching can be paused and disposed of.

 

Welcome to your any question and inquiry!

Hot Products

Danfoss Type EVR 15 NC 7/8'' Refrigeration Solenoid Valve 24VDC 220VAC The shown is danfoss type EVR ...
Danfoss Type EVR 20 NC Refrigeration Solenoid Valve 7/8'' 24VDC 220VAC The shown is danfoss type EVR ...
Danfoss Type EVR 25 NC Refrigeration Solenoid Valve 1 1/8'' 24V DC 220V AC The shown is danfoss type ...
Turbo BH10 Bag Filter Dust Collector Pulse Jet Solenoid Valve Coil Solenoid valves are electronicall...
ASCO Type 400325 Series Pulse Jet Valve Replacement Magnetic Coil These external circuits can be as ...
11mm Inner Diameter ASCO Type MP-C-146 Solenoid Valve Coil AC solenoids are inherently more energy ...