Ningbo Brando Hardware Co., Ltd |
Verified Suppliers
|
|
12V DC 113-030-0278 113-030-0047 System 13 30mm Width Nass Magnet Coil
Features:
1. Product Name: Nass Magnet Replacement Solenoid Coil
2. Voltages: 12VDC, 24VDC, 24VAC, 110VAC, 120VAC, 220VAC, 230VAC,
240VAC (50/60Hz)
3. Power: 22VA, 13W, 20W
4. Connector: DIN 43650 Form A Plug
5. Insulation Class: Class H, Class, F
6. Protection Class: IP65
7. Application Examples: Auto Drain Valve, Shako Solenoid Valve,
such like PU220, PU225, SPU225, etc.
Technical parameter of electronic drain valve solenoid coils:
Code No | Voltage | Frequency (Hz) | Power W/VA | |
113-030-0042 | 24VDC | 2,0 | ||
113-030-0045 | 48VDC | 2,1 | ||
113-030-0032 | 48VDC | 1,6 | ||
113-030-0032 | 220VAC | 50 | 6,4 | |
113-030-0032 | 230VAC | 50 | 6,6 | |
113-030-0032 | 240VAC | 50 | 5,7 | |
113-030-0278 | 12VDC | 6,0 | ||
113-030-0026 | 24VDC | 6,1 | ||
113-030-0029 | 24VAC | 50 | 10,8 | |
113-030-0029 | 24VAC | 60 | 9,6 | |
113-030-0036 | 110VAC | 50 | 11,1 | |
113-030-0036 | 120VAC | 60 | 11,7 | |
113-030-0033 | 220VAC | 50 | 10,8 | |
113-030-0044 | 12VAC | 50 | 19,3 | |
113-030-0044 | 12VAC | 50 | 17,1 | |
113-030-0027 | 24VDC | 11,0 | ||
113-030-0039 | 24VAC | 50 | 17,9 | |
113-030-0039 | 24VAC | 60 | 15,6 | |
113-030-0037 | 110VAC | 50 | 17,6 | |
113-030-0037 | 120VAC | 50 | 18,3 | |
113-030-0034 | 220VAC | 50 | 18,1 | |
113-030-0034 | 240VAC | 60 | 18,9 | |
113-030-0033 | 240VAC | 50 | 11,4 | |
113-030-0047 | 12VDC | 15,0 | ||
113-030-0028 | 24VDC | 15,0 | ||
113-030-0040 | 24VAC | 50 | 21,8, | |
113-030-0040 | 24VAC | 50 | 19.4 | |
113-030-0043 | 48VAC | 50 | 26,2 | |
113-030-0043 | 48VAC | 50 | 23,2 | |
113-030-0052 | 48VAC | 50 | 19,0 | |
113-030-0052 | 48VAC | 50 | 16,6 | |
113-030-0038 | 110VAC | 50 | 24,8 | |
113-030-0049 | 110VAC | 50 | 21,7 | |
113-030-0049 | 110VAC | 50 | 19,2 | |
113-030-0038 | 120VAC | 50 | 26,1 | |
113-030-0041 | 195VDC | 16,6 | ||
113-030-0035 | 220VAC | 50 | 22,0 | |
113-030-0050 | 230vAC | 50 | 21,4 | |
113-030-0050 | 230VAC | 50 | 19,0 | |
113-030-0031 | 240VAC | 50 | 17,9 | |
113-030-0035 | 240VAC | 50 | 23,2 |
Main dimension of 5043/5045 solenoid coils for water electronic
drain valve:
Detail enlargement of 14 mm Inside Hole 42 High electric solenoid coils:
Connection of AC220V/DC24V black electromagnetic coils in electronic drain valve:
The working principle of the automatic drain valve of the dryer:
The refrigerating dryer (hereinafter referred to as the dryer) is
compressed by the air compressor, cooled by the rear cooler,
separated by the gas-water separator, and the compressed air of the
buffer tank is generally saturated, and its relative humidity is
100%. Moreover, it contains impurities such as oil and solid
particles. This compressed air cannot be directly used and needs to
be dried and purified. In order to discharge the condensate in the
dryer in time and completely, the easiest way is to open a drain
hole at the end of the evaporator to continuously discharge the
condensed water generated in the machine. But its drawbacks are
also obvious. Because the compressed air is also continuously
discharged while draining, the compressed air pressure drops
rapidly. This is not allowed for the gas source system. Manually
draining the hand valve is feasible, but it requires a lot of
manpower and a series of management troubles. With the automatic
drainer, the water in the machine can be automatically eliminated
at regular (quantitative).
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your inquiry!