In contrast to a standard Single-acting Pneumatic cylinder, a Double-acting Pneumatic cylinder uses the output force in both forward and backward motion. This is done through the use of both the air exhaust and air pressure valves, these valves use compressed air to push the piston road in both directions.
Specifications of SU Series Pneumatic Cylinder:
Bore Size (mm) | 32 | 40 | 50 | 63 | 80 | 100 | |
Acting Type | Double Acting | ||||||
Fluid | Air (to be filtered by 40μm filter element) | ||||||
Mounting Type | SU | Basic FA FB CA CB LB TC TCM1 | |||||
SUD, SUJ | Basic FA LB TC TCM1 | ||||||
Operating Pressure Range | 0.1 to 1.0 MPa (1.0 to 10.0 bar) (15 to 145 psi) | ||||||
Proof Pressure | 1.5 MPa (15 bar) (215 psi) | ||||||
Temprature (℃) | -20 to +80 | ||||||
Speed Range (mm/s) | 30 to 800 | ||||||
Cushion Type | Variable cushion | ||||||
Adjustable Cushion Stroke (mm) | 21 | 28 | 29 | ||||
Port Size | 1/8'' | 1/4'' | 3/8'' | 1/2'' |
Stroke of SU Series Pneumatic Cylinder:
Symbol of SU Series Pneumatic Cylinder:
Ordering Code of SU Series Pneumatic Cylinder:
Criteria for selection: Cylinder thrust:
Installation & Usage:
1. When load changes in the work, the cylinder with abundant output
capacity shall be ed.
2. Relative cylinder with high temperature resistance or corrosion
resistance shall be chosen under the condition of high temperature
or corrosion.
3. Necessary protection measure shall be taken in the environment
with higher humidity, much dust or water drops, oil dust and
welding dregs.
4. Dirty substances in the pipe must be eliminated before cylinder
is connected with pipeline to prevent the entrance of particles
into the cylinder.
5. The medium used by cylinder shall be filtered to 40μm or below.
6. Anti-freezing measure shall be adopted under low temperature
environment to prevent moisture freezing.
7. The cylinder shall be carried out test run without load before
application. Prior to run, buffer shall be turned to the minimum
and gradually released to avoid the damage on cylinder caused by
excessive impact.
8. The cylinder shall avoid the influence of side load in operation
to maintain the normal work of cylinder and extend the service
life.
9. If the cylinder is dismantled and stored for a long time, please
conduct anti-rust treatment to the surface. Anti-dust caps shall be
added in air inlet and outlet ports.