Home Companies Ningbo Brando Hardware Co., Ltd

ASCO Type 400425-142 24VDC Dust Collector Pulse Jet Valve Electromagnetic Coil

Ningbo Brando Hardware Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China

Contact name:Brandon Bao

Inquir Now

Ningbo Brando Hardware Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

ASCO Type 400425-142 24VDC Dust Collector Pulse Jet Valve Electromagnetic Coil

Country/Region china
City & Province ningbo zhejiang
Categories Valves
InquireNow

Product Details

ASCO Type 400425-142 24VDC Dust Collector Pulse Jet Valve Electromagnetic Coil

 

The 400325642 400325101 400325118 ASCO Type solenoid coil is applied to ASCO SCG353A043, SCG353053 Pulse Valves. The pulse valve is The compressed air switch of the pulse bag type dust collector cleaning system is controlled by the pulse blowing controller, and the filter bag is sprayed and cleaned step by row, so that the resistance of the dust collector is kept within the set range. In order to ensure the dust collector's processing capacity and dust collection efficiency is good.
 
Hole Size: 14mm
Height: 40mm
Width: 44.5mm
Voltage: 24VDC
Power: 28VA, 18W
Connection: DIN43650A
Insulation Class: H
Enameled Wire Material: Copper
Suitable Valve Number: SCG353A047, SCG353A050, SCG353A051, SCEX353.060
 
Technical Data:
 
Model numberBB14040007
Ref number400425-142, 400425-144, 400425-101, 400425-105, 400425-118, 400425-117
Normal voltageAC110V, AC220V, DC12V, DC24V (Other can be customized)
Normal powerAC:28VA, DC: 18Watt
MaterialBMC, Brass
Wire classH
ConnectionDIN43650A
ApplicationASCO SCG353A047, SCG353A050, SCG353A051, SCEX353.060 Pulse Valve
Hole diameter14 mm
Height40 mm
Width44.5 mm

 

Valve ModelRepair KitsSolenoid Coils
ACDC24VDC24 VAC110VAC220VAC
SCG353A043C113444C113444400325642400325101400325118400325118
ACG353AD44C113444C113444400325642400325101400325118400325118
ACG353052C113444C113444400325642400325101400325118400325118
SCG353053C113444C113444400325642400325101400325118400325118
SCG353AD47C113827C113827400425342400425101400425118400425117
SCG353050C113685C113686400425342400425101400425118400425117
SCG353051C113685C113686400425342400425101400425118400425117
SCG353060C123432C123433400425342400425101400425118400425117
SCG353AD65C113827C113827400425342400425101400425118400425117

 

Main Dimension of 400325-142 ASCO Type Pulse Valve Coil:

400425-142 24V DC Replacement Solenoid Valve Coil For ASCO 353 Series Dust Collector Pulse Valve

 

Dust collection system with Pulse Diaphragm Valve Electric Magnetic Coils:

The boiler dust collector cleaning control adopts three control modes: time control, differential pressure control and hybrid control, which realizes automatic and manual control mode switching, and realizes automatic switching and manual switching in the field. At the same time, backflushing and ash removal can realize off-line and double-line ash removal.


(1) Automatic control
When the boiler dust collector is in operation, the ash removal control can be selected according to time, pressure difference or mixing mode, usually by mixed control method (time and pressure difference combined). The hybrid control method is based on time and selects the pressure difference. According to the given pressure difference design value, if the pressure difference is less than the set value during operation, it will work according to the set time; if the pressure difference is greater than the set value, the equipment will be cleaned immediately. When cleaning the ash, each room of the dust collector is sprayed with ash. When the complete cleaning is completed, when the pressure is less than the set value, the timed cleaning is entered. If the pressure is still greater than the set value, the cleaning is continued. The timing cleaning is entered until the pressure is less than the set value.


(2) Manual control
In the on-site operation cabinet, each room can be manually controlled according to the cleaning procedure, once cleaned, and each room can be cleaned separately. The on-site operation cabinet is equipped with a manual operation switch device working status indicator light, which is used for cleaning the production check and debugging of each equipment of the system.

 

Product Characteristic:
1. Using high quality wire which has UL approved;
2. Using high quality permeablity magnetic material which contain low carbon;
3. Using high quality housing material like PA66, PBT, PPS, BMC and so on.
4. Insulation class can be B, F, H, N, C;
5. Protection class can be IP65, IP67 & IP69K;
6. We also offer special coils like ex-proof coils, water proof coils and so on.
7. If you have special requirement, pls feel free to contact us.

 

Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing


Welcome to your any question and inquiry!

Hot Products

ASCO Type 400425-142 24VDC Dust Collector Pulse Jet Valve Electromagnetic Coil The 400325642 ...
Range Rover Air Suspension Solenoid Valve Coil RVH000055 RVH500050 This is solenoid coil is ...
ASCO Type 400425-101 24VAC Dust Collector Pulse Jet Valve Solenoid Coil The 400425-142 400425-144 ...
C113444 1'' ASCO Type SCG353 Series Pulse Valve Diaphragm Repair Kit For Dust Collector System This ...
C113447 1-1/2'' NBR Buna Diaphragm Repair Kit For ASCO Type SCG353A047 Dust Collector Pulse Jet ...
C113685 2'' NBR Buna Pulse Jet Valve Diaphragm Repair Kit For ASCO Type SCG353A051 Dust Collector ...