Home Companies Ningbo Brando Hardware Co., Ltd

2 - 1/2 Inch Submerged BFEC Type Pneumatic Pulse Valve DMF-Y-62S With ADC12 Aluminum Body

Ningbo Brando Hardware Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China

Contact name:Brandon Bao

Inquir Now

Ningbo Brando Hardware Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

2 - 1/2 Inch Submerged BFEC Type Pneumatic Pulse Valve DMF-Y-62S With ADC12 Aluminum Body

Country/Region china
City & Province ningbo zhejiang
Categories Valves
InquireNow

Product Details

2 - 1/2 Inch DMF-Y-62S Submerged BFEC Type Pneumatic Pulse Valve With ADC12 Aluminum Body

 

DMF-Y-62S is G2-1/2 inch Electromagnetic Pulse Valve For Dust Collector Baghouse Cleaning System.

The pulse valve diaphragm divides the pulse valve into front and rear-an air chamber.
When the electromagnetic pulse valve is connected to the clean compressed air in the pulse bag type dust removal system, the compressed air passes through the orifice and enters the rear air chamber. At this time, the pressure of the rear air chamber presses the diaphragm against the valve outlet. The pulse valve is closed.
The pulse controller outputs a signal to move the armature of the pulse valve, the vent hole of the air chamber behind the valve is opened, the back air chamber quickly loses pressure, the diaphragm is moved backward, and compressed air is blown through the valve's air outlet. Start.
The electric signal output by the pulse controller disappears, the electromagnetic pilot head armature of the pulse valve is reset, the vent hole of the rear air chamber is closed, and the pressure of the rear air chamber is increased, so that the diaphragm of the pulse valve is close to the outlet of the valve. Blowing stops.
The length of the blowing time is controlled by a controller.

 

Specification of Submerged Type In Line Electromagnetic Pulse Valve DMF-Y-62S:

Model NumberDMF-Y-62S
Port SizeG 2-1/2 Inch
Membrane sizesΦ188
KV136.58
CV159.39
Blowing Area27-38
Working MediaClean Air 
Temperature-25℃ to +80℃ or customized
Pressure 0.1~0.8Mpa
VoltageDC24V, AC24V, AC110V, AC220V or customized

 

Overall Dimension of 2-1/2 Inch Pulse Diaphragm Valve In Dust Collector:

Overall Dimension

 

Deconstruction Diagram of DMF-Y-62S Pulse solenoid valve Embedded Type BFEC:

Coil Copper
Armature Assembly 430FR Stainless Steel 
Seal & Diaphragm NBR, HNBR, FKM, EPDM, Silicone, All Available
Spring 321 Stainless Steel 
Valve BodyDie casting Aluminum Alloy 

 

Details About Double Diaphragm Pulse Jet Valve DMF-Y-62S:

More Details About DMF-Y-62S On YOUTUBE:


 

 

Troubleshooting tips for your dust collector’s pulse clean system


Check the pressure in the air manifold – should be 85-100 psi – clean, dry air, with sufficient volume to maintain pressure.

Check that there is power to the timer control – power light will glow when there is power to the control.

 

Electrical
Each solenoid has a terminal connected to the output channel on the timer board, and a terminal connected to the solenoid common terminal.
If a pressure switch is connected to the timer board, confirm it is calling for cleaning. If no pressure switch is used, the p.s. terminals are jumpered together on the timer board.

Timer board is not sequencing, check fuse.

When the timer board is sequencing, an indicator light for each output channel will glow momentarily, as the channel is energized.

 

Pneumatic
Diaphragm Valves are normally closed. They open for a split second to allow a burst of compressed air to pulse the filter.
If a diaphragm valve is stuck open, check for leaks in the plastic tubing and fittings.

Hold a finger over the small bleed port at the end of the electrical solenoid, if air is leaking from this port, the solenoid needs rebuild / replaced.

If no leaks from solenoid valve and tubing, depressurize the manifold and clean/replace the diaphragm and spring in the pulse valve.

If diaphragm valve will not open, confirm there is no kinks in the tubing and check that the electrical solenoid is operating.

 

 

Welcome to your any question and inquiry!

Hot Products

AC110V AC220V DC24V 1'' DN25 Threaded Port NBR Diaphragm SCG Series Pulse Jet Valve With Straight ...
BSPT 1/4'' 4V220-08 AirTAC Type Pneumatic Solenoid Valve Double Electrical Control Light DC24V ...
AC110V AC220V DC24V 1 1/2 '' DN40 Threaded Port NBR Diaphragm SCG Series Straight Through Type ...
4V230C-08 PT 1/4'' AirTAC Type Air Solenoid Valve Double Electrical Control 5/3 Way 12VDC Features ...
2 - 1/2 Inch DMF-Y-62S Submerged BFEC Type Pneumatic Pulse Valve With ADC12 Aluminum Body DMF-Y-62S ...
AC 110V DC 12V 1 1/2 '' DN40 SCG353A047 Threaded Port NBR Diaphragm Power Pulse Valves For Dust ...