INSTALLATION:
1. MM valves are installed through the tank.
2. to avoid any potential operational problem it is preferable that the valves are not mounted underneath the tank where condensation may collect. all o-rings should be coated with a silicone based lubricant or similar.
3. dresser nut seals where used are a pressure seal only, not a structural component. do not rely on dresser seals to retain either the tanks or blowtubes. tanks and blowtubes must be independently restrained.
4. tighten dresser nuts to 20Nm max.
SUITABLE FOR:
dust collector application,in particular for reverse pulse jet
filter cleaning including bag filters, cartridge filters, envelope
filters, ceramic filters, and sintered metal fiber filters.
Technical parameters of Goyen Type MM Series Reverse Pulse Jet
Valves:
model no | CA25MM | CA40MM | CA50MM | CA62MM | CA76MM | CA102MM | ||
nominal size | 25 | 40 | 50 | 62 | 76 | 102 | ||
port size | mm | 25 | 40 | 50 | 62 | 76 | 102 | |
inch | 1'' | 1 1/2'' | 2'' | 2 1/2'' | 3'' | 3 1/2'' | 4'' | |
pressure range | 0.3 to 0.8MPa | |||||||
temp range | nitriles seals | -40 to 82℃ | ||||||
viton seals | -29 to 232℃ |
Main Dimension Diagram of 2 1/2 Inch CA62MM Goyen Type Dust
Collector Pulse Valve:
Details of 2 1/2 Inch CA62MM Goyen Type Diaphragm Valve In Reverse
Pulse Jet System:
Tips: All accessories can be sold separately as repair parts
(Diaphragm, Solenoid Coil, Armature Assembly)
MAINTENANCE
Before conducting any maintenance activity on the system ensure
that components are fully isolated from pressure and power
supplies. Pressure and power should not be reapplied until the
valve has been fully assembled. Diaphragm and pilot inspection
should be conducted annually.
INSTALLATION
1. Prepare supply and blowtube pipes to suit valve specification.
Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other
particulate.
3. Ensure supply air is clean and dry.
4. Mount valves to inlet pipes and blowtube to valves, ensuring no
excess thread sealant can enter the valve itself.
5. Make electrical connections to solenoid or connect RCA pilot
port to pilot valve (RCA valves only).
6. Apply moderate pressure to system and check for installation
leaks.
7. Fully pressurise system.
8. Test fire and listen for proper actuation and crisp pulse noise.
Youtube video of 2 1/2 Inch CA62MM Goyen Type Dust Collector Pulse
Solenoid Valve:
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!