Ningbo Brando Hardware Co., Ltd |
Verified Suppliers
|
|
1/2'' Welding Type MSV-1078/4 Electromagnetic Valve Refrigeration
Spare Parts For Temperature Control AC/DC
The MSV-1078/4 refrigeration solenoid valves are used in
chillers to control temperature by controlling the flow of
refrigerants.The chilled water circulation system is widely used:
industry, agriculture, surface treatment, electroplating, laser,
printing, food, beverage, cosmetics, toys, chemicals, hardware,
building materials, automobiles, electronics, electrical
appliances, electromechanical and other 16 industries, more than 30
Industry; high-power chillers are widely used in hotels, office
buildings for central air conditioning, plastic cooling, food
preservation, bath temperature, medical storage and other
industries.So our MSV-1078/4 solenoid valve are widely used in
industiral refrigeration system.
Technical data of MSV-1078/4 1/2 inch port size refrigeration
solenoid valve:
Model number: | Connection size | Dimension | KV value | |||||||
H1 | H2 | L1 | Q | |||||||
Inch | mm | Inch | mm | Inch | mm | Inch | mm | |||
MSV-1020/2 | 1/4''SAE | 3.0 | 75 | 2.5 | 62.5 | 2.3 | 58 | 0.175 | ||
MSV-1020/3 | 3/8''SAE | 3.0 | 75 | 2.5 | 62.5 | 2.6 | 65 | 0.23 | ||
MSV-1028/2 | 1/4''ODF | 3.0 | 75 | 2.5 | 32.5 | 4.9 | 125 | 0.15 | ||
MSV-1028/3 | 3/8''ODF | 3.0 | 75 | 2.5 | 62.5 | 4.9 | 125 | 0.23 | ||
MSV-1064/3 | 3/8''SAE | 3.2 | 82 | 2.7 | 69.5 | 2.6 | 68 | 0.8 | ||
MSV-1064/4 | 1/2''SAE | 3.2 | 82 | 2.7 | 69.5 | 2.8 | 72 | 0.8 | ||
MSV-1068/3 | 3/8''ODF | 3.2 | 82 | 2.7 | 69.5 | 4.5 | 111 | 0.8 | ||
MSV-1068/4 | 1/2''ODF | 3.2 | 82 | 2.7 | 69.5 | 5.0 | 127 | 0.8 | ||
MSV-1070/4 | 1/2''SAE | 3.6 | 91 | 3.0 | 75.0 | 3.9 | 100 | 1.8 | 45 | 2.2 |
MSV-1070/5 | 5/8''SAE | 3.6 | 91 | 3.0 | 75.0 | 4.2 | 106 | 1.8 | 45 | 2.61 |
MSV-1078/4 | 1/2''ODF | 3.6 | 91 | 3.0 | 75.0 | 5.0 | 127 | 1.8 | 45 | 2.2 |
MSV-1078/5 | 5/8''ODF | 3.6 | 91 | 3.0 | 75.0 | 6.9 | 173 | 1.8 | 45 | 2.61 |
MSV-1078/6 | 3/4''ODF | 3.7 | 96 | 3.0 | 75.0 | 7.0 | 179 | 1.8 | 45 | |
MSV-1078/9 | 1 1/8''ODF | 4.5 | 115 | 3.8 | 96.0 | 9.8 | 250 | 3.1 | 80 | 10 |
MSV-1078/11 | 1 3/8''ODF | 6.8 | 172 | 5.4 | 138.0 | 10.9 | 278 | 2.8 | 68 | 16 |
MSV-1090/5 | 5/8''SAE | 4.2 | 106 | 3.0 | 78.0 | 1.7 | 120 | 2.2 | 57 | 3.8 |
MSV-1090/6 | 3/4''SAE | 4.2 | 106 | 3.0 | 78.0 | 4.9 | 124 | 2.2 | 57 | 4.8 |
MSV-1079/7 | 7/8''ODF | 3.6 | 91 | 3.0 | 75.0 | 7.5 | 190 | 1.8 | 45 | 2.61 |
MSV-1079/11 | 1 3/8''ODF | 4.5 | 115 | 3.8 | 96.0 | 11.5 | 292 | 3.1 | 80 | 10 |
MSV-1079/13 | 1 5/8''ODF | 6.8 | 172 | 5.4 | 138.0 | 10.9 | 278 | 2.8 | 68 | 16 |
MSV-1098/7 | 7/8''ODF | 4.2 | 106 | 3.0 | 78.0 | 7.1 | 180 | 2.2 | 57 | 5.7 |
MSV-1099/9 | 1 1/8''ODF | 4.2 | 106 | 3.0 | 78.0 | 8.5 | 216 | 2.2 | 57 | 5.7 |
MSV1099/11 | 1 3/8''ODF | 6.2 | 157 | 5.0 | 127.0 | 10.9 | 291 | 2.8 | 68 | 10 |
Overall Dimension of MSV-1078/4 Solenoid Valve In Refrigeration
Condensing Units:
Different Connection type and size of MSV-1078/4 Refrigeration
solenoid valve refrigerant flow control:
Application of MSV-1078/4 Solenoid Valve In HVAC Refrigeration
Units:
Introduction of Water cooling and Air cooling units with
MSV-1078/4 refrigeration solenoid valve:
Generally, chillers are divided into water cooling and air cooling.
The air-cooled chiller contains a water tank and a water pump,
eliminating the need for cooling tower cooling. Easy to install and
move. However, the environmental requirements are high. First,
because it is cooled by hot air circulation, if the ventilation
effect of the installation workshop is not good, it will directly
affect the cooling effect of the chiller. In addition, if you want
to put the chiller in a dust-free workshop with humidity
requirements, it will generate a lot of water vapor on the top of
the machine.
The water-cooled chiller is divided into an open chiller, a sealed
type (some called a box chiller) and a screw chiller. Water-cooled
chillers must be equipped with additional cooling towers and pumps
to achieve better cooling. The open chiller has to be equipped with
a separate water tank, which is not necessary because it has a
built-in water tank. The open type is generally installed outside
the workshop for easy maintenance, but because it is not
aesthetically pleasing, a sealed water-cooled chiller is produced.
The sealed water-cooled chiller is a box structure that is easy to
install and easy to use, and is popular among the customers of
Meisen Refrigeration. However, if you have a very high demand for
cooling capacity, we recommend that you use a screw chiller. If you
have a chiller compressor requirement of 100HP or higher, we
recommend a screw chiller.
Second, the chilled water circulation refrigeration unit is
equipped:
1. Compressor;
2. Pump;
3. Computer PC board, touch control, safe and convenient;
4. Thermostat: liquid crystal display temperature control
electronic board;
5. Expansion valve, refrigeration solenoid valve, filter;
6. One 304 stainless steel water tank with built-in insulation
material;
7. Electrical LG
8. Security protection system
Compressor delay start protection
Welcome to your inquiry!