Right Angle Big Size Pneumatic Pulse Valve 3 inch Aluminum Alloy For Dust Removal

 

The DMF-Z-76S is a large solenoid valve, and the 3-inch inlet and outlet ports are suitable for use in high-power dust removal equipment. Right angle solenoid valve, the angle between the inlet and outlet is 90 degrees. Suitable for installation and connection of air bag and dust collector blow pipe.

 

Pls Contact us if necessary!

 

DMF: Electro-magnetic pulse Valve

Z: Rogjt Angle

X: Diameter

S: Double Diaphragms

X: Temperature Level

 

Technical Data

TypeDiameterNumber of diaphragmSize of inlet diaphragmOutlet orifice connectionweight(kg)
 mminch    
DMF-Z-20Dia. 203/4"1G3/4''G3/4''0.62kg
DMF-Z-25Dia. 251"1G1''G1''0.8kg
DMF-Z-40SDia. 401'1/2"2G1'1/2"G1'1/2"1.4kg
DMF-Z-50SDia. 502"2G2'1/2"G2"2.7kg
DMF-Z-62SDia. 622'1/2"2G2'1/2"G2'1/2"3.5kg
DMF-Z-76SDia. 763"2G3"G3"4.3kg

 

Dimensional drawing of DMF-Z-76S

Solenoid diaphragm

Blowing in and out

High quality Coil

Performance test

 

1, open voltage test
In the air inlet of the electromagnetic pulse valve, connect the clean air with the nominal pressure of the air source. Input the electric signal of 85% of the nominal voltage and 0.03s of the width on the electromagnetic valve to check whether the electromagnetic pulse valve is open normally.

 

2, close the air pressure test
In the air inlet of the electromagnetic pulse valve, connect the clean air with a pressure of 0.1 MPa, input the electrical signal to close the valve, and check whether the electromagnetic pulse valve is reliably closed.

 

3, pressure resistance test
In the air inlet of the electromagnetic pulse valve, the clean air with a pressure of 0.8 MPa is connected for 60 minutes, and the leakage of the sealing parts on the electromagnetic pulse valve is checked.

 

4, insulation resistance test
(1) Measure the insulation resistance of the electromagnetic coil to the outer casing under the specified environmental conditions using a 500V meter with a range of 0MΩ to 500MΩ and an accuracy of 1 meter.
(2) Put the valve in the temperature regulation and humidity control box, and set the temperature to 35 degrees, and the relative humidity is 85%, apply a 50Hz, 250V sinusoidal AC voltage between the electromagnetic coil and the valve body for 1min. Check for breakdown.

 

5, anti-vibration test
The valve is fixed on the vibration test bench, and after the vibration frequency is 20 Hz, the full amplitude is 2 mm, and the vibration is 30 min, the fasteners of each part of the valve are checked for looseness and the work is normal.

 

6, diaphragm life test
The clean air of the nominal pressure is connected to the air inlet of the electromagnetic pulse valve, and the nominal voltage value of the width of 0.1 s and the interval of 3 s is input on the electromagnetic valve, and the number of consecutive or cumulative operations of the valve is recorded.

 

please care the products details at our website, any confuse please contact us or Note your request online. Big quantity purchase ,please contact our online service to ask more economic shipping way or discuss the more pretty price.

 

Wait your inquiry!

Hot Products

Danfoss Type EVR 40 NC Refrigeration Solenoid Valve 1 5/8'' 2 1/8'' Refrigeration solenoid valves ...
Right Angle Big Size Pneumatic Pulse Valve 3 inch Aluminum Alloy For Dust Removal The DMF-Z-76S is a ...
1'' DMF-ZM-25 BFEC Quick Mount Pulse Diaphragm Valve For Dust Removal Pulse valves (also called ...
Danfoss Type Solenoid Valve EVR 32 042H1104 042H1106 042H1108 A solenoid is a simple form of an ...
DMF-Y-102S SBFEC Type Embedded Pulse Jet Valve For Dust Extraction Pulse Jet Valve, also called ...
EVR20 Refrigeration Solenoid Valves -40°C-105°C HCFC/HFC/CFC Brass Natural Color EVR20 Refrigeration ...