Home Companies QINGDAO ENNENG MOTOR CO.,LTD.

20kw 37kw 55kw TYB Rare Earth AC Synchronous PM Motor For Fans And Pumps

QINGDAO ENNENG MOTOR CO.,LTD.

Contact Us

[China] country

Trade Verify

Address: No. 18, Xinye Road, High-Tech Zone, Qingdao,Shandong, China

Contact name:Cindy

Inquir Now

QINGDAO ENNENG MOTOR CO.,LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

20kw 37kw 55kw TYB Rare Earth AC Synchronous PM Motor For Fans And Pumps

Country/Region china
City & Province qingdao shandong
Categories Inverters & Converters
InquireNow

Product Details

20kw 37kw 55kw TYB Rare Earth Material AC Synchronous Permanent Magnet Motor For Fans And Pumps

 

Product Parameters


Energy efficiency standards

comply with GB30253-1 grade

Work mode
S1
Installation dimensions
comply with IEC standard

Control mode

variable frequency vector control
Power range7.5 〜160kW
Governing range

constant torque: 0〜3000r/min
Cooling way
IC411 (fan cooling)

Field Weakening: 3000 〜3600r/min
Power range7.5 〜250kW
Governing range

constant torque: 0〜1500r/min
Cooling way
IC416 (independent axial flow fan)
Field Weakening: 1500 〜1800r/min
Insulation classF
Optional parts

Encoder, spiral transformer, PTC, PT100
Protection grade
IP54 (IP23 customizabe)

Wiring type

junction box (aviation plug can be customized as per requirement)
installationIMB3 IMB5 IMB35
Service factor

Standard 1, 2 (customized as per requirement)

Required environment

below 1000m altitude

temperature -15〜45°C

relative humidity below 90%

 

Model Type

 


Model

Power
(kW)

rated volt (V)

rated current
(A)

frequency
(Hz)

No. of poles

rated speed
(r/min )

rated torque
(N • m )

efficiency
(%)

weight
(kg)
TYB-132M1-67.538014.5756150047.892.661
TYB-132M2-6113802175615007093.673
TYB-160M1-61138021075615007093.6108
TYB-160M2-61538028.5756150095.B94124
TYB-160L1-618.538035.17561500117.894.3132
TYB-160L2-622380415756150014094.7141
TYB-225S1-830B8056.41008150019195261
TYB-225S2-83738069.410081500235.6953274
TYB-225M1-84538084.110081500286.595.6284
TYB-225M2-855380102.61008150035095.8297
TYB-225MX-875380141.710081500477.596336
TYB-280S-890380169.71008150057396.2484
TYB-280M1-81103802071008150070096.4512
TYB-280M2-8132380248.11008150084096.5555
TYB-315S-8160380300.8100815001018.796.5756
TYB-315M-8200380375.6100815001273.396.6850
TYB-315L1-8220380413.2100815001400796.6910
TYB-315L2-8250380469.1100815001591796.71055
          

Model

Power
(kW)

rated volt (V)

rated current
(A)

frequency
(Hz)

No. of poles

rated speed
(r/min )

rated torque
(N • m )

efficiency
(%)

weight
(kg)
TYB-132M1-47.538014.61004300023.992.171
TYB-132M2-41138021.110043000359387
TYB-160M1-41538028.71004300047.893.4118
TYB-160M2-42238041.7100430007094.4126
TYB-180M1-43038056.71004300095.594.5175
TYB-180M2-43738069.810043000117.894.8186
TYB-200L1-44538084.610043000142.395.1241
TYB-200L2-455380103.11004300017595.4259
TYB-225M-47538014110043000238.895.6388
TYB-225MX-490380168.710043000286.595.8421
TYB-280S1-8110380205.72008300035096486
TYB-280S2-8132380246.92008300042096534
TYB-280M-8160380398.62008300050996.2698

Advantages:

 

1. Small and Light

Volume ratio: average 35% smaller, weight ratio: average 40% lighter

Motor Frame Size Is decreased by 1 ~ 3, compared with the asynchronous motor.

It can realize mechanical miniaturization to save space.

 

2. High Power Factor

Reduce the capacity of power-receiving equipment.

There is no doubt of high efficiency. Compared with asynchronous motors, it may reduce the current volume of equipment due to the high power factor.

 

3. High Efficiency•Energy Saving

Motor efficiency is equal to IE3 (High efficiency: above GB2 level)

Note: IE3 is the efficiency grade specified in IEC 60034-30.

 

Detailed pictures
 
 
The cases for reference (PM Motor for water pump):
 
 
Installation Size:

 

Maintenance and repair of electric motors:

 

1. The operating environment should always be kept dry, the surface of the motor should be kept clean, and the air inlet should not be obstructed by dust, fibers, etc.

 

2. When a protection alarm occurs, the cause of the failure should be found out, and the operation can only be put into operation after the failure is eliminated.

 

3. When the machine is stopped for inspection, the operation can only be carried out after the motor has completely stopped.

 

4. In order to ensure good lubrication of the motor during operation, the motor should run for about 4000 hours, that is, the grease should be supplemented or replaced (the closed bearing does not need to be replaced during the service life). When the bearing is found to be overheated or the grease deteriorates during operation, The grease should be replaced in time. When replacing the grease, remove the old grease and clean the oil grooves of the bearings and bearing caps with gasoline. For motors with a speed of 1500r/min and below, refill the bearing grease type for medium and small motors bearing grease No. 2, and fill the inner and outer rings of the bearing About two-thirds of the gap between the bearings; the motor speed of 2500r/min and above is filled with bearing grease type HTHS, which fills about one-half of the gap between the inner and outer rings of the bearing.

 

5. When the life of the bearing is over, the vibration and noise of the motor will increase obviously. Check that the radial clearance of the bearing reaches the value in the table below, and the bearing should be replaced.

 

Storage and transportation of electric motors:

 

1. The motor should be kept dry during storage to avoid sudden changes in ambient temperature.

 

2. The storage of the motor should not be too high to avoid damage to the lower motor.

 

3. The motor should be prevented from tipping or inverting during storage and transportation.

Hot Products

High-Efficiency Water Cooled PMSM Permanent Magnet Electric Motor Energy Efficiency Standards comply ...
5-3MW Energy Saving Permanent Magnet AC Motor Energy Efficiency Standards comply with GB30253-1 ...
Energy Saving Liquid Cooled High Torque Permanent Magnet Motor Energy Efficiency Standards comply ...
Energy Saving 3 Phase Permanent Magnet Motor For Cooling Tower What Is The Permanent Magnet ...
Low Maintenance Variable Speed Permanent Magnet Motor For Cooling Tower Energy efficiency standards ...
PMAC High Efficiency Eco Friendly Permanent Magnet Synchronous Motor What Is The Permanent Magnet ...