Low Speed Three Phase 160kw 3600rpm Interior Permanent Magnet Motor

 

Analysis of the principle of the technical advantages of permanent magnet motor

 

The principle of a permanent magnet synchronous motor is as follows: In the motor's stator winding into the three-phase current, after the pass-in current, it will form a rotating magnetic field for the motor's stator winding. Because the rotor is installed with the permanent magnet, the permanent magnet's magnetic pole is fixed, according to the principle of magnetic poles of the same phase attracting different repulsion, the rotating magnetic field generated in the stator will drive the rotor to rotate, The rotation speed of the rotor is equal to the speed of the rotating pole produced in the stator.

 

Detailed pictures
 
 
Main Features:
 
1. Easy to change
The same installation size as the asynchronous motor.Due to the same motor seat No. Design with an asynchronous motor(output<315kW), it can be easily changed.
 
2. High Power Factor
 
Reduce the capacity of power-receiving equipment. There is no doubt of high efficiency. Compared with asynchronous motors and standard-type synchronous motors, it can reduce the current volume of equipment due to the high power factor.
 
3. Speed control corresponding to the height
 
It is PG vector control. Suitable for the printer, and punch compactor.
 
4. High Efficiency • Energy Saving

 

Motor efficiency is equal to IE4 (Ultra high efficiency: above GB1 grade)
Note: IE4 is an efficiency grade specified in IEC 60034-30.

 

Differences Between The Permanent Magnet Motor And Asynchronous Motor:

 

01. Rotor Structure

 

Asynchronous motor: The rotor consists of an iron core and a winding, mainly squirrel-cage and wire-wound rotors. A squirrel-cage rotor is cast with aluminum bars. The magnetic field of the aluminum bar cutting the stator drives the rotor.

 

PMSM Motor: The permanent magnets are embedded in the rotor magnetic poles, and are driven to rotate by the rotating magnetic field generated in the stator according to the principle of magnetic poles of the same phase attracting different repulsion.

 

02. Efficiency

 

Asynchronous motors: Need to absorb current from the grid excitation, resulting in a certain amount of energy loss, motor reactive current, and low power factor.

 

PMSM Motor: The magnetic field is provided by permanent magnets, the rotor does not need exciting current, and the motor efficiency is improved.

 

03. Volume And Weight

 

The use of high-performance permanent magnet materials makes the air gap magnetic field of permanent magnet synchronous motors larger than that of asynchronous motors. The size and weight are reduced compared to asynchronous motors. It will be one or two frame sizes lower than asynchronous motors.

 

04. Motor Starting Current

 

Asynchronous motor: It is directly started by power frequency electricity, and the starting current is large, which can reach 5 to 7 times the rated current, which has a great impact on the power grid in an instant. The large starting current causes the leakage resistance voltage drop of the stator winding to increase, and the starting torque is small so heavy-duty starting cannot be achieved. Even if the inverter is used, it can only start within the rated output current range.

 

PMSM Motor: It is driven by a dedicated controller, which lacks the rated output requirements of the reducer. The actual starting current is small, the current is gradually increased according to the load, and the starting torque is large.

 

05. Power Factor

 

Asynchronous motors have a low power factor, they must absorb a large amount of reactive current from the power grid, the large starting current of asynchronous motors will cause a short-term impact on the power grid, and long-term use will cause certain damage to the power grid equipment and transformers. It is necessary to add power compensation units and perform reactive power compensation to ensure the quality of the power grid and increase the cost of equipment use.

 

There is no induced current in the rotor of the permanent magnet synchronous motor, and the power factor of the motor is high, which improves the quality factor of the power grid and eliminates the need to install a compensator.

 

06. Maintenance

 

Asynchronous motor + reducer structure will generate vibration, heat, high failure rate, large lubricant consumption, and high manual maintenance cost; it will cause certain downtime losses.

 

The three-phase Permanent magnet synchronous motor drives the equipment directly. Because the reducer is eliminated, the motor output speed is low, mechanical noise is low, mechanical vibration is small, and the failure rate is low. The entire drive system is almost maintenance-free.

 

The three-phase Permanent magnet synchronous motor drives the equipment directly. Because the reducer is eliminated, the motor output speed is low, mechanical noise is low, mechanical vibration is small, and the failure rate is low. The entire drive system is almost maintenance-free.

 
 

Hot Products

OEM ODM Service Low Speed 3 Phase PMSM Motor Without Gearbox What Is The Permanent Magnet Synchronou...
Energy Saving Low Starting Current 3 Phase PMSM Motor For Belt Conveyor What Is The Permanent Magnet ...
Brushless AC 3 Phase Variable Frequency Drive PMSM Motor For Belt Conveyor What Is The Permanent ...
Eco-Friendly Direct Drive Gearless Neodymium Magnet 3 Phase PMSM Motor What Is The Permanent Magnet ...
High-Efficiency Water Cooled PMSM Permanent Magnet Electric Motor Energy Efficiency Standards comply ...
Environmentally Friendly High- Efficiency Permanent Magnet Electric Motor Energy Efficiency ...