Product Details

Abnormal waveform ECG signal simulator, Arrhythmia, PVC, VPC, ECG signal generator

Model:SKX-2000SUP

Introduction:

This model simulator suitable for ECG machine manufacturer, or ECG kind product manufacturer. It can be used to adjust machine, and use for ECG machine development.

Feature:


Rechargeable Lithium battery

10 pcs multi-functional ECG connector, can be connect with different type ECG machine cable or patient monitor cable

Battery power indicate light

Low battery power automatic turn off function, protect the Lithium battery


Description


The waveform type description ( using the Mindray PM8000 monitor detection )


1, waveform code 1: normal ECG waveform

The data code at 60 is mean :heart rate 60 bpm

The frequency range is 10-200 BPM and wave amplitude is fixed, it will not be affected by the amplitude setting.


2, waveform code 2: It is represent triangular waveform waveform code

Data code at 75 : it is mean heart rate 75bpm

Frequency range: 10-400bpm

Amplitude range: 0.1-4mV, the amplitude can be regulated in regulate setting place


3, waveform code 3: Square waveform

Data code at 10 : it is mean 1Hz

Frequency range: 0.1-10Hz

Amplitude range: 0.1-4mV, the amplitude can be regulated in regulate setting place


4, Waveform code 4 :Sinusoidal waveform

Data code at 10 : it is mean 10Hz

Frequency range : 1-100Hz

Amplitude range: 0.1-4mV, the amplitude can be regulated in regulate setting place


5, Waveform code 5: QRS wave waveform

You can change the amplitude of T wave, QRS wave amplitude, width of QRS wave, QRS wave frequency

To change these parameters through the combination of keys

6.Waveform code at 6: Respiratory waveform

Data code at 30: it is mean 30bpm

Respiratory waveform frequency adjustment range 10-120 times


7, Waveform code 7: pacing signal ,the pacing pulse signal of positive and negative direction

Data code at 20 ( It is represent 2mS )

The frequency is 60bpm

Amplitude range: 0.1-4mV, the amplitude can be regulated in regulate setting place

Through the combination of keys to switch the positive and negative direction

You can change the pulse width, the range is 0.5-2mS


8, Waveform code 8: QRS wave of front pacing signals

Front pacing signal is positive and negative pulse waveform, through the combination of keys to switch

The width of pacing signal pulse can be adjusted, the range is 0.5-2mS

Amplitude range: 0.1-4mV, the amplitude can be regulated in regulate setting place


9, Waveform code 9: adjust the waveform amplitude

Data code at100 : it is represent 1Mv

400: it is represent 4Mv


10, waveform code at A:

Data code

bpm

Symptom

Data code at 1

75bpm

Normal

Data code at 2

140bpm

Tachycardia

Data code at 3

35bpm

Bradycardia

Data code at 4

200bpm

T supraventricular tachycardia

Data code at 5

80(73)bpm

Missed beat

Data code at 6

14 bpm

Agony rhythm

Data code at 7

0 bpm

Cardioplegia


11, Waveform code at B:

Data code

bpm

Symptom

Data code 1

75 bpm

Normal

Data code 2

82 bpm

NSR with PAC

Data code at 3

82 bpm

Coarse atrial fibrillation, arhythmia

Data code at 4

80 bpm

premature ventricular contraction

Data code at 5

80 bpm

Continuation 2 premature ventricular contraction

Data code at 6

80 bpm

Continuation 3 premature ventricular contraction

Data code at 7

80 bpm

Continuation 4 premature ventricular contraction

Data code 8

80 bpm

Premature beat

Data code 9

80 bpm

2 continuation premature beat

Data code 10

80 bpm

4 continuation premature beat

Data code 11

80 bpm

1 premature beat,1 normal waveform

Data code 12

80 bpm

All premature beat(VF/VT)


12, waveform code at C:

Data code

bpm

Symptom

Data code at 1

60 bpm

Degree block

Data code at 2

35 bpm

Degree block 30 bpm

Data code at 3

31 bpm

Degree block 31 bpm

Data code at 4

60 bpm

L bnd1 branch block

Data code at 5

60 bpm

R bnd1 branch block


13, waveform code at D:

Data code number

bpm

Symptom

Data code at 1

(80-83) bpm

ATRIAL PAC

Data code at 2

60 bpm

Pvc1 early Lv focus

Data code at 3

60 bpm

Pvc1 early Rv focus

Data code at 4

60 bpm

Nodal pnc

Data code at 5

60 bpm

PVCs bigeminy

Data code at 6

60 bpm

PVCs trigeminy

Data code at 7

80 bpm

R ON T

Hot Products

Model: SKX-1000E SpO2 Function introduction: 1. External imitate finger,you can connect to any SpO2 ...
Abnormal waveform ECG signal simulator, Arrhythmia, PVC, VPC, ECG signal generator Model:SKX-2000SUP ...
Model: SKX-1000D Introduction: Designed to test accuracy of SpO2 sensor, easy and convenience, ...
2015 NEW SpO2 simulator for development use,Oxygen saturation simulator,Oximetry simulator SpO2 ...
2015 NEW SpO2 simulator,Oxygen saturation simulator,Oximetry simultor for SpO2 sensor test ...
Name: Compatible Datex OXY-W-UN neonate wrap SpO2 sensor probe Quick details: Properties: Monitor ...