Home Companies Xiamen ZhiCheng Automation Technology Co., Ltd

SV vortex flowmeters with display for water based media SV4610 SVN12XXXIRKG/US-100

Xiamen ZhiCheng Automation Technology Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 903-3, building F02, phase III Software Park, Jimei district, Xiamen city,CHINA (361000)

Contact name:Andy

Inquir Now

Xiamen ZhiCheng Automation Technology Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

SV vortex flowmeters with display for water based media SV4610 SVN12XXXIRKG/US-100

Country/Region china
City & Province xiamen guangdong
Categories Flow Switches
InquireNow

Product Details

Product characteristics
Number of inputs and outputsNumber of digital outputs: 2
Measuring range
16...317 gph0.26...5.28 gpm
Process connectionthreaded connection 1/2" NPT DN8
Application
Systemgold-plated contacts
Applicationfor industrial applications
Mediawater; glycol solutions; Coolants
Medium temperature [°F]14...194
Pressure rating [bar]12
Pressure rating [psi]174
Note on pressure rating
up to 40 °C
MAWP (for applications according to CRN) [bar]3.9
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 30
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]< 3
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Overload protectionyes
Measuring/setting range
Measuring range
16...317 gph0.26...5.28 gpm
Display range
0...380 gph0...6.34 gpm
Resolution
1 gph0.02 gpm
Set point SP
19...317 gph0.32...5.28 gpm
Reset point rP
16...314 gph0.26...5.24 gpm
Frequency end point, FEP
63...317 gph1.06...5.28 gpm
In steps of
1 gph0.02 gpm
Frequency at the end point FRP [Hz]100...1000
Measuring dynamics1:20
Temperature monitoring
Measuring range [°F]14...194
Display range [°F]-22...230
Resolution [°F]1
Set point SP [°F]16...194
Reset point rP [°F]14...192
In steps of [°F]1
Frequency start point, FSP [°F]14...158
Frequency end point, FEP [°F]50...194
Frequency at the end point FRP [Hz]100...1000
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range)± 2 % MEW; (water)
Repeatability± 0,5 % MEW
Temperature monitoring
Accuracy [K]± 1
Reaction times
Flow monitoring
Response time [s]1; (dAP = 0)
Damping process value dAP [s]0...5
Temperature monitoring
Dynamic response T05 / T09 [s]T09 = 6
Software / programming
Parameter setting optionshysteresis / window; normally open / closed; switching logic; Frequency output; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO modeyes
Required master port classA
Process data analog2
Process data binary2
Min. process cycle time [ms]3
Supported DeviceIDs
Type of operationDeviceID
default486
Operating conditions
Ambient temperature [°F]32...140
Note on ambient temperature
medium temperature < 176 °F
medium temperature < 194 °F: 32...122 °F
Storage temperature [°F]-4...176
ProtectionIP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2 
DIN EN 61000-6-3 
Shock resistance
DIN EN 60068-2-275 g (11 ms)
Vibration resistance
DIN EN 60068-2-6with water / 10...50 Hz 1 mm
 with water / 50...2000 Hz 2 g
MTTF [years]342
UL approval
UL approval numberI001
Pressure equipment directivesound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g]481.5
Materialstainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U
Materials (wetted parts)stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM
Tightening torque [Nm]30
Process connectionthreaded connection 1/2" NPT DN8
Remarks
Remarks
MW = Measured value
MEW = Final value of the measuring range
Pack quantity1 pcs.
Electrical connection
ConnectionConnector: 1 x M12; coding: A; Contacts: gold-plated
Diagrams and graphs
Pressure loss
dPPressure loss
Qvolumetric flow quantity
pressure rating (bar)
 
 

Hot Products

Product characteristics Number of inputs and outputs Number of digital outputs: 2 Measuring range 16...
Application Design for level sensors LR Measuring/setting range Probe length L [mm] 150 Mechanical ...
Application short-circuit monitoring; Wire break monitoring Electrical data Operating voltage ...
Product characteristics Number of inputs and outputs Number of digital outputs: 1 Measuring range ...
Product characteristics Electrical design PNP/NPN Output function normally open Sensing range [mm] 5 ...