Product Details

RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring

 

 

Principle: The turbidity online analyzer injects a laser beam from the air into the water in a direction perpendicular to the water surface. The laser light is scattered by the suspended particles in the water, and the sensor in the water detects the scattered light intensity in a direction 90 degrees from the incident light, and converts the scattered light intensity into a turbidity value according to the calibration table.

 

DRFN is a professional production and sales of turbidity meter, turbidity meter, online turbidity meter, online turbidity meter, mlss sludge concentration meter, ss suspended solids concentration meter, online dissolved oxygen meter, fluorescence dissolved oxygen meter, sludge interface Manufacturer of online monitoring and analysis instruments for water quality such as instrument, residual chlorine analyzer, ultrasonic liquid level meter, PH meter and so on.

 

Specification:

ModelDUC2-TU-S-D
Software VersionDRFN TU Analysis software V1.0
Sensor InputCompatible with all DRFN's TU Digital Sensors
Display Range0.001NTU~4000NTU
Resolution0.001 NTU
Relay Control2 settable SPST relays with a maximum load of 3A/250VAC
Analog Current Output2 settable 0/4~20mA current outputs with a maximum load 1000Ω
Communication MethodTwo-wire RS485 interface; MODBUS RTU; support JSON text data format
OTA

Default WIFI

Display Screen

128*64 black-and-white graphic lattice LCD

adjustable backlight mode

adjustable display rate

Configuration InformationPower off protection, parameters are retained indefinitely
Time/Data Record

Year/month/day/hour/min/second, record 14000 historical data

record interval can be set between 1~999 minutes

Maintenance RecordsLast 100 times
Protection LevelIP66
Operating Environment0~60℃,RH<95% ( no condensation)
Storage Environment-20~70℃,RH<55% ( no condensation, precision instruments)
Shell MaterialEnhanced ABS
Dimension144*144*120 mm
Mounting MethodWall mounting, pipe clamping, panel installation (hole size 138*138 mm)
Electrical InterfaceThe back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm
Power Supply

18~36VDC

Power ConsumptionAbout 12W
WeightAbout 800g

Please click the user manual of RS485 turbidity controller here:

DUC2 -HTU Turbidity controller user manual.pdf

 

Brief introduction:

● Compatible with all DRFN digital infrared turbidity sensors;
● Separately have a list of controller and sensor settings for quick and detailed parameter setting;
● The working status of the sensor can be queried, including reading the serial number;
● Support a variety of installation methods;
● Time and historical data recording function;
● 3.2-inch large LCD screen;
● User-friendly Chinese and English language interface;
● Password can be set to prevent misoperation;
● 2 SPST multi-function and settable relays;
● Two 0/4~20mA active current loop outputs;
● RS485 interface, Modbus RTU communication protocol;
● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;

● OTA download technology as a smart configuration option for the instrument;

 

Aplication:
◇ Tap water
◇ Water station
◇ Surface water
◇ Sewage

◇ Industrial water

◇ Swimming pool


FAQ

Q1. What are the advantages of a digital turbidity meter?

A: The digital universal controller is matched with the corresponding digital sensor to realize the measurement. Compared with the traditional instrument and sensor combination, the biggest advantage is that the data transmitted from the sensor to the controller is more stable and accurate, the application is flexible, and the use is more convenient.

 

Q2. How does this turbidity controller collect data?

A: This digital turbidity meter is a single-parameter universal controller. Each controller will be pre-installed with a set of embedded software to correspond to different sensors. These connected sensors upload the detected data with a special encrypted communication method to ensure that the controller can collect high-precision data more stably. The controller will display the collected data on the display screen in real time, which is convenient for users to read.

 

Q3.Can customer's logo be added to the controller system and cover?
Of course, we support OEM services for customers. 

 

Q4.How long is the warranty period?
The company guarantees the instrument for one year (12 months) from the date of shippment, and the consumables and wearing parts in the equipment are not covered by the warranty.

 

Q5. Does the turbidity controller with a OTA function:

Yes. Our DUC2-TU-S Turbidity controller with OTA

 

Hot Products

100mS/cm digital RS485 conductivity probe for swage water online detecting Measuring Conductivity It ...
RS485 Interface Remote Signal Turbidity Controller For Water Station Monitoring​ Turbidity ...
4~20mA Current Signal Output Turbidity Meter For Tap Water Detecting Turbidity, that is, the degree ...
Relay Control Communication Data Collection Turbidity Transmitter For Surface Water The turbidity ...
RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring Principle: The ...
RS485 Output 1000 NTU Turbidity Sensor For Industrial Sewage Water Detecting DRFN turbidity sensor ...