Home Companies Suzhou Delfino Environmental Technology Co., Ltd.

Built-In Temperature Unit RS485 Interface PH Probe Sensor For Water Treatment Detecting

Suzhou Delfino Environmental Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Suzhou Xupai Road No.3

Contact name:Yuki Fu

Inquir Now

Suzhou Delfino Environmental Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Built-In Temperature Unit RS485 Interface PH Probe Sensor For Water Treatment Detecting

Country/Region china
City & Province suzhou
Categories Water Treatment
InquireNow

Product Details

Built-In Temperature Unit RS485 Interface PH Sensor For Water Treatment Detecting

 

 

DRFN online digital pH sensor, industrial online digital pH sensor is a new generation of intelligent water quality detection digital sensor independently developed by our company. The industrial online digital PH sensor can be used for data viewing, debugging, maintenance, etc. through the mobile phone APP or computer. It has the characteristics of easy maintenance, good stability, good repeatability and multi-function, and can accurately measure the pH value and temperature value in the solution.

 

It is widely used in wastewater treatment, pure water, circulating water, boiler water and other systems, as well as PH value detection in electronics, aquaculture, food, printing and dyeing, electroplating, pharmaceuticals, fermentation, chemical industry and other fields. Powerful functions in system applications.

 

Digital pH adopts industrial online electrodes, and the front end of the electrode is a flat structure, which is easy to clean. The built-in temperature sensor can automatically compensate the temperature, which is suitable for online long-term monitoring environment.

 

The digital pH sensor adopts RS485 output and supports Modbus, which can realize networking and system integration without a controller. Not affected by transmission distance, better stability, built-in temperature sensor, automatic temperature compensation, digital sensor, RS-485 output, support MODBUS.

 

 

Specification:

Product Name
PH sensor electrode
Product Model
DPH700-YD01A
Brand Name
Daruifuno
Electrical Isolation
Without
Signal Type
Digital(RS485 interface)
Measuring Range
PH: 0~14pH TEMP: 0~50℃
Resolution
0.01pH/0.1℃
Accuracy
±0.02pH
Temperature Compensation
Automatic, built-in temperature unit

 Calibration Method

 

  Zero position/slope/deviation
Work Pressure
0~2Bar
Operating Temperature
0.0~50.0℃
Shell Material
ABS
Dimension
Diameter: 35mm Total length: 260 mm ( include cleaning cover)
Installation Size
1"NPT at both ends of the installation thread;
insertion depth 100 (including cleaning plug 115)
  Protection Grade

  IP68

 

Please click the user manual of RS485 pH sensor here:

DPH7 digital pH User Manual.pdf

 

Features& Advantages
● All-in-one package, can be used with the online transmitters, DTU, and portable instruments
● RS485 interface, Modbus RTU, support access to standard industrial control system
● The protection grade is IP68, can work continuously and stably under water for a long time
● Internal storage of calibration data, support offline calibration, plug and play on site

 

 

Aplication:

Water treatment monitoring

Drinking water,surface water,water quality analyze,ground water,ect.

 

Industrial process monitoring and dosing control

Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

 

FAQ

1. What is the measurement principle of this pH electrode?
A:
The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.

 

2. How to judge the pH of the solution?
A:
If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7.


3. What is the wire length of the pH electrode?
A:
The lead wire of this electrode is 1 m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.

 

4. How often must the pH sensor be calibrated?
A: Depends on the type of sample:
Dirty samples and non-aqueous samples require more frequent calibration.
Depends on the required accuracy:
For very accurate measurements, at least daily calibration is required.
Depends on the quality of the electrode:
Old electrodes require more frequent calibration.
 
5. The pH sensor with RS485 output, modbus?
Yes. our DPH700 and DPH790 all with RS485 Modbus RTU / JSON text data format.

Hot Products

RS485 Interface PH Controller -2~+16pH For Water Treatment Monitoring DUC2-PH-H-A is a self...
Digital pH Meter With cleaning control For Industrial Processing Control DUC2-PH-H-D is a self...
OTA Online PH Transmitter with two settable 0/4~20mA current outputs DUC2-PH-H-A pH transmitter is ...
Date Record RS485 Interface PH Water Analyzer For Water Quality Monitoring DUC2-PH-S-D pH controller...
Built-In Temperature Unit RS485 Interface PH Sensor For Water Treatment Detecting DRFN online ...
RS485 Interface Electrical Isolation PH Probe For Industrial Process Measuring PH digital sensor can ...