Home Companies Suzhou Delfino Environmental Technology Co., Ltd.

Contamination Resistant Three Electrode Total Chlorine Sensor For Direct Drinking Water Conductivity 10μS/Cm

Suzhou Delfino Environmental Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Suzhou Xupai Road No.3

Contact name:Yuki Fu

Inquir Now

Suzhou Delfino Environmental Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Contamination Resistant Three Electrode Total Chlorine Sensor For Direct Drinking Water Conductivity 10μS/Cm

Country/Region china
City & Province suzhou
Categories Instrument Parts & Accessories
InquireNow

Product Details

Contamination Resistant Three Electrode Total Chlorine Sensor For Direct Drinking Water (Conductivity > 10μS/Cm).

 

Total chlorine refers to the sum of free chlorine and combined chlorine in the water. Free chlorine is chlorine that is not bound to organic or inorganic substances, usually in the form of free chlorine, such as chlorine gas or hypochlorite ions. Combined chlorine refers to compounds formed by combining chlorine with organic or inorganic substances, such as chloramine compounds.

 

Disinfection water quality control: Chloride is one of the most commonly used water treatment disinfectants. It is used to kill microorganisms in water and ensure the health and safety of drinking water and swimming pool water. Therefore, understanding the total chlorine content in water is the key to ensuring disinfection effectiveness.

 

Water quality safety monitoring: Total chlorine content is an indicator of water quality safety. Too high or too low total chlorine content may cause water quality problems. For example, too high a content may produce odor and taste, or even harmful substances, while too low a content may not be enough to kill pathogenic microorganisms in the water.

 

Environmental protection: Monitoring total chlorine content helps to understand the discharge of chloride in water bodies and prevent excessive chloride discharge from affecting the aquatic ecosystem.

 

Regular measurement of total chlorine levels is critical to maintaining water safety, protecting public health, and protecting the environment.

 

DCP4.0MA Total chlorine sensor Three-electrode system, used for drinking water, swimming pool water, service water, process water, sea water and salt water, direct drinking water (conductivity not less than 10μs/cm), medical sewage, pH 4~12, greatly reducing dependence on pH value. Resistant to pollution, low conductivity, almost no maintenance required, optional range 0~2/5/10/20/50ppm

 

Areas of application: Swimming pool water, drinking water, sea water, brine (15% NaCl) Surfactants (tensides) are partially tolerated.

Scope of supply: CP4 sensor, membrane cap, electrolyte

Specifications

Item Number

  CP4.0

 indicator

Total chlorine (= free chlorine + bound chlorine)

Reduced dependence on pH

 Application

  Swimming pool water, drinking water, sea water, brine (15% NaCl)     

  Surfactants (tensides) are partially tolerated.

 Chlorination agents

inorganic chlorine compounds:

NaOCl (=sodium hypochlorite), Ca(OCl)2 , chlorine gas, electrolytically generated chlorine

 Measuring system  Membrane covered, amperometric potentiostatic 3-electrode system with electronic         inside

 

 

 

 

Electronic

Analog version: - voltage output

- not galvanically isolated electronics

- analog internal data processing

- output signal: analog (analog-out/analog)

Digital version: - electronic is completely galvanically isolated

- digital internal data processing

- output signal: analog (analog-out/digital)

or

digital (digital-out/digital)

mA-version: - current output analog

- not galvanically isolated electronics

- output signal: analog (analog-out/analog)

 

Information about themeasuring range

The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope

Note: With a slope > 100% the measuring range is reduced accordingly.

(Ex.: 150% slope → 67% of the specified measuring range)

Accuracy

after calibration at repeatability

  conditions (25°C, pH 7.2 in       drinking water) of the upper full   scale

- Measuring range 2 mg/l:     at 0.4 mg/l  <2%
                                              at 1.6 mg/l  <2%
- Measuring range 20 mg/l:
                                              at 4 mg/l      <1%
                                              at 16 mg/l <3%
 

Slope drift

At repeatability conditions (25 °C, pH 7,2 in drinking water)

  approx. -1% per month

 

Working temperature

Measuring water temperature: 0 … +45 °C

(no ice crystals in the measuring water)

  Ambient temperature: 0 … +55 °C
  Temperature compensation

Automatically, by an integrated temperature sensor

Sudden temperature changes must be avoided

 

 

Max. allowed working

pressure

Operation without retaining ring:

- 0.5 bar

- no pressure impulses and/or vibrations

Operation with retaining ring in TARAflow FLC:

- 3 bar,

- no pressure impulses and/or vibrations (see option 2)

Flow rate

(Incoming flow velocity)

approx. 15-30 l/h (33 – 66 cm/s) in FLC, small flow rate dependence is given

 pH-range

pH 4 – pH 12, reduced dependence on pH-value

(see diagram last page of the data sheet “Slope of  CP4 versus pH”)

 Conductivity 10 µS/cm – 200 mS/cm (brine)
 Run-in time First start-up approx. 2 h
 Response time T90 : approx. 3 min. (brine approx. 5 min.)
 Zero point adjustment Not necessary
 calibration

At the device, by analytical determination, DPD-4-Method

(DPD- 1 + DPD-3)

 

Cross sensitivities/

interferences

ClO2 : factor 1

O3: factor 1.3

Corrosion inhibitors can lead to measuring errors.

Stabilisers for water hardness can lead to measuring errors.

 Absence of the disinfectantMax .24 h

 

Connection

mV version:                          5-pole M12, plug-on flange

Modbus version:                   5-pole M12, plug-on flange

4-20 mA version:                   2-pole terminal

or

5-pole M12, plug-on flange

 max. length of sensor cable   (depending on internal   signal processing)analog< 30 m
digital

> 30 m are permissible

Maximum cable length depends on application

Protection type

5-pole M12 plug-on flange: IP68

2-pole terminal with mA-hood: IP65

 materialMicroporous hydrophilic Membrane, PVC-U, PEEK, stainless steel 1.4571

 

 

Size

diameter:                               approx. 25 mm

Length: mV version                  approx. 190 mm (analog signal processing)

                                            approx.. 205 mm (digital signal processing)           

             Modbus version              approx. 205 mm

             4-20 mA version             approx. 220 mm (2-pole-terminal)

                                             approx. 190 mm (5-pole-M12)

Transport+5 … +50 °C (Sensor, electrolyte, membrane cap)

 

 

storage

Sensor: dry and without electrolyte no limit at

+5 … +40 °C

Electrolyte: in original bottle protected from sunlight at +5 … +35 °C min.

1 year or until the specified EXP-Date

Membrane cap: in original packing no limit at +5 … +40 °C

(used membrane caps can not be stored)

 

maintenance

Regularly control of the measuring signal, min. once a week

The following specifications depend on the water quality:

Change of the membrane cap: once a year

Change of the electrolyte: once a year

EMC tested

RoHS compliant

Option 1:

Membrane cap M48.4S

 

especially for applications in sea water or brine

Option 2:

Retaining ring

 

- When operating with pressures >0.5 bar in TARAflow FLC

- Dimensions retaining ring 29 x 23.4 x 2.5 mm, slitted, PETP

- Different positions for groove selectable

(on request)

 

Spare parts

TypeMembrane capElectrolyteEmery  O-ring

 

 

All CP4.0

M48.4E

Art. No. 11051-E

 

ECP1.4/GEL, 100 ml Art. No. 11006.1

 

 

S1

Art. No. 11908

 

 

14 x 1.8 NBR Art. No. 11806

For sea water or brine

applications:

M48.4S

Art. No. 11051-S

 

CP4.0 (digital output, digital internal signal processing)

- The power supply is galvanically isolated inside of the sensor.

- The output signal is galvanically isolated too, that means potential-free.

 

Measuring

range

in ppm

Resolution

in ppm

Output

Output resistance

Power supplyConnection
CP4.0H-M0c0.005… 2.0000.001

 

Modbus RTU

There are no terminating resistors in the sensor.

 

 

9-30 VDC

approx. 20-56 mA

5-pole M12 plug-on flange

Function of wires:

PIN1: reserved

PIN2: +U

PIN3: power GND

PIN4: RS485B

PIN5: RS485A

CP4.0N-M0c0.05… 20.000.01
CP4.0H-M4c *0,005… 2,0000.001

(Subject to technical changes!)

 

CP4.0 4-20 mA (analog output, analog internal signal processing)

A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation.

Electrical connection: 2 pole terminal clamp

 

Measuring

range

 

 

in ppm

Resolution

 

in ppm

Output

Output resistance

Nominal slope

(at pH 7.2)

 

in mA/ppm

Power

supply

Connection
CP4.0MA0.50.005…0.5000.001

 

 

 

4…20 mA

uncalibrated

32.0

 

12…30 VDC

RL 50Ω…RL 900Ω

 

2-pole terminal (2 x 1 mm²)

 

Recommended: Round cable

4 mm

2 x 0.34 mm²

CP4.0MA20.005…2.0000.0018.0
CP4.0MA50.05…5.000.013.2
CP4.0MA100.05…10.000.011.6
CP4.0MA200.05…20.000.010.8

(Subject to technical changes!)

 

Electrical connection: 5 pole M12 plug-on flange

 

Measuring

range

 

in ppm

Resolution

 

in ppm

Output

Output resistance

Nominal

slope

(at pH 7.2)

 

in mA/ppm

Power

supply

Connection
CP4.0MA0.5-M120.005 …0.5000.001

 

 

 

4…20 mA

uncalibrated

32.0

 

 

 

12…30 VDC

RL 50Ω…RL 900Ω

 

5-pole M12 plug- on flange

Function of wires: PIN1: n. c.

PIN2: +U

PIN3: -U

PIN4: n c.

PIN5: n. c.

CP4.0MA2-M120.005…2.0000.0018.0
CP4.0MA5-M120.05…5.000.013.2
CP4.0MA10-M120.05…10.000.011.6
CP4.0MA20-M120.05…20.000.010.8

(Subject to technical changes!)

Hot Products

High Accuracy Fast Response Lazer Water Tubidity Sensor For Secondary Water Supply For low-range ...
Flow Cell Type Lower Turbidity Water Tubidity Sensor For Drinking Water Drinking water flow-through ...
High Precision and Stability RS485 lazer Water Tubidity electrode for treated water​ Daruifuno's ...
High Accuracy 0-100NTU Water Lower Tubidity Sensor For Industry Treated Water Daruifuno high...
High Accuracy 0-100NTU Water Lower Tubidity Sensor For Pure Water Flow cell type Lower Tubidity ...
Contamination Resistant Three Electrode Total Chlorine Sensor For Direct Drinking Water (Conductivit...