Home Companies Tianjin Estel Electronic Science and Technology Co.,Ltd

UPS Room Electrical Cabinet Air Conditioner High Precision 600 Watt 693×427×200 mm

Tianjin Estel Electronic Science and Technology Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Shenzhen, China

Contact name:Fiona Liang

Inquir Now

Tianjin Estel Electronic Science and Technology Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

UPS Room Electrical Cabinet Air Conditioner High Precision 600 Watt 693×427×200 mm

Country/Region china
City & Province shenzhen guangdong
Categories Toilet Tissue
InquireNow

Product Details

 

UPS Room Electrical Cabinet Air Conditioner High Precision 600 Watt 693×427×200 mm

 

Quick Details:

 

Place of Origin: Shenzhen, China (Mainland)Rated Cooling Capacity : 600W
Brand Name: ESTELRated Heating Capacity:300/500W (optional)
Model: TC06-60JFH/01(KT036)Dimension: H×W×D 693×427×200mm
Product Name: Outdoor Cabinet Air ConditionerInput Voltage: AC220V/50Hz
Certification: ISO9001, CE, 3C, FCC, TLCRated Input Current: 1.5A
Cover: including outer coverRated Input Power: 330W
Color: greyWorking Temperature: -20°C ~ +55°C
Protection Level: IP55Noise: ≤60dB
Installation Mode: door mounted, side mountedRefrigerant: R134a
Support OEMCooling Method: compressor, active cooling

 

Payment & Shipping Terms:

 

Minimum Order Quantity:1 set
Price:negotiation
Payment Terms:L/C, D/A, D/P, T/T, Western Union
Supply Ability:16,000 sets per month
Delivery Time:7-10 working days
Packaging Details:carton + wooden case + pallet

 

1. Specifications

(1) Technical Parameters

 

Environmental Performanceworking environmental temperature-20°C ~ 55°C
storage temperature-40°C ~ 70°C
working humidity≤95%
Thermal Performancerated cooling capacity

650W(L35 L35)

600W(L25 L35)

rated heating capacity300W/500W (optional)

 

Electrical Performance

rated input current

1.6A(L35 L35)

1.5A(L25 L35)

rated input power

352W(L35 L35)

330W(L25 L35)

rated input voltageAC220V/50Hz (185V~264V)

 

Dimension Diagram: H×W×D: 693×427×200mm

 

Size

Model

SpecsABCDEFGHIJK
TC06-60JFH/01(KT036)600W300401450600671693166200585370427


Door Hole-opening Diagram(mm):

 

Size

Model

SpecsLMNOPQR
TC06-60JFH/01(KT036)600W401380300671652600450

 

Installation Diagram:

 

 

2. Description

 

TC06-60JFH/01(KT036) Air Conditioner is a full automation temperature control product. It uses intelligent controller to control the whole system of the air conditioner. According to the variation of environment temperature, the intelligent controller can automatically detect, operate and record the whole system’s operating time, power consumption, event and historical data. It can store 100 event records and 1280 historical data records, and can enquire 256 days’ daily record information.

 

3. Application

 

The product is widely applied in telecom cabinet, small and medium sized telecom room, UPS room, outdoor base station room, etc.

 

4. Features

 

(1) Good design, stable structure and easy maintenance.

(2) It can be integrated with heat exchanger. Reliable performance, environmental friendly and energy saving.

(3) The protective level of internal and external circulation is IP55, which can protect cabinet to avoid moisture, dust, water. The air conditioner can be indoor or outdoor installed.

(4) R134a system.

(5) Digital temperature controller and high precision of temperature control.

(6) The main components have CE certifications, which can meet EU RoHS requirements.

 

5. System Principle Diagram

 

 

6. Electrical Wiring Diagram

 

Wiring Ports:

 

L N PE : power supply port (voltage input: 220VAC±15% 50Hz)

F+ F- : direct ventilation output port

AL1 AL2: general alarm output port

A+ B- SGND: RS485 communication port

N: not connected pin

 

7. System Control

7.1 Function and Application

 

ET731 intelligent air conditioner controller is a universal intelligent controller, controlling with highly integrated STC SCM. It can intelligently control thermostatic cabinet air conditioner working and hydrogen exhausting, including functions such as fault self diagnosis, power-on self start, or restart after unexpected failure caused by other reasons. The controller is compatible with all types of air conditioners in the market.

 

The controller, with the features of advanced performance, easy installation and setting, are widely used in telecom cabinet, small and medium sized telecom room, UPS room, outdoor base station room, etc.

 

7.2 Technical Parameter

 

  • 2×16 Chinese/English shift LCD display, user friendly;
  • Simultaneously display temperature and humidity inside the box and communication room temperature;
  • Temperature measurement accuracy: 0.1 °C; humidity measurement accuracy:5%;
  • Can store 180 days’ daily event record, 1 record every day;
  • Daily highest temperature, lowest temperature, average temperature
  • Daily event record;
  • Save the former day’s daily data at 0:00 every day; Can query 180 days’ daily record information;
  • RS485 communication, YD/T 1363.1-2005 standard protocol, support remote detection and control;
  • Control mode: pulse (Non dry contact air conditioner), conducting (dry contact air conditioner)
  • Real-time control air conditioner on/off
  • Power supply: AC185V~264V/50HZ;
  • Power consumption:≤5W;
  • Working environment: -30°C~70°C; <90%RH;
  • Installation method: guide rail,hanging;
  • Dimension(L×W×H):150mm×190mm×45mm

 

7.3 Operating Instruction

 

ET731 uses English interfaces, which can be operated easily. All the operations can be realized with four buttons. The following is the control board diagram:

 

  • Check operating parameters of key parts inside air conditioner, namely observation parameter. Operation steps:

 

Observation Parameter: on the left of line 1 is Parameter No. (PAnn); on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.

 

  • Revise operating parameters of air conditioner, namely control parameters. Operation steps:

 

 

Control Parameter: on the left of line 1 is Parameter No. (PCnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.

 

  • Revise basic parameters of air conditioner. Operation steps:

 

 

Basic Parameter: on the left of line 1 is Parameter No. (PBnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.

 

  • Manual Operation Mode:

 

Operation steps:

 

 

 

Enter the interface to select “Cool” (cooing), “Heater” (heating), “Air” (direct ventilation) to conduct manual start (ON) and stop (OFF) operation.

 

  • Event Query Mode:

 

Operation steps:

 

 

8. Mainboard Wiring Diagram

 

 

Our Delivery Agent

 

The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

 

10. Our Contact Information

 

Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

           lxf.estel@hotmail.com
Skype: fiona.liang10

 

Hot Products

700W Door Mounted Electrical Enclosure Air Conditioner Low Energy Consumption Quick Details: Place ...
UPS Room Electrical Cabinet Air Conditioner High Precision 600 Watt 693×427×200 mm Quick Details: ...
KT033 Communication Outdoor Cabinet Air Conditioner Rated Input Power 264W Quick Details: Place of ...
400W Active Cooling Outdoor Cabinet Air Conditioner Cutomized Low Noise Quick Details: Place of ...
AC220V 50Hz 450W Outdoor Telecom Cabinet Air Conditioner With Intelligent Controller Quick Details: ...
High Intelligence Outdoor Cabinet Air Conditioner Industrial Compressor Air Cooler Quick Details: ...